FX2N-16MR Discontinued Replacement: FX3U-16MR/ES Input: 8 DC 24V Drain Output: 8 Relay
FX2N-16MR-ES/UL Discontinued Replacement Model: FX3U-16MR/ES Input: 8 points DC24V drain/source output: 8 points Relay
FX2N-16MS Discontinued replacement model: FX3U-32MS/ES Input: 8 points DC24V drain output: 8 points Thyristor
FX2N-16MT Discontinued replacement model: FX3U-16MT/ES Input: 8 points DC24V drain output: 8 points transistor drain type
FX2N-16MT-ESSS/ULDiscontinued Replacement Model: FX3U-16MT/ESS Input: 8 points DC24V drain/source output: 8 points Transistor Source type
FX2N-16MT-E/ULDiscontinued replacement model: FX3U-16MT/ES Input: 8 points DC24V drain output: 8 points transistor drain type
FX2N-32MRDno longer available replacement: FX3U-32MR/ES Input: 16 points DC24V drain output: 16 points Relay
FX2N-32MR-ES/ULDiscontinued Replacement: FX3U-32MR/ES Input: 16 points DC24V drain/source output: 16 points Relay
FX2N-32MS Discontinued replacement model: FX3U-32MS/ES Input: 16 points DC24V Drain Output: 16 points Thyristor
FX2N-32MS-E/UL Discontinued Replacement Model: FX3U-32MS/ES Input: 16 points DC24V Drain Output: 16 points Thyristor
FX2N-32MT Discontinued Replacement Model: FX3U-32MT/ES Input: 16 points DC24V Drain Output: 16 points Transistor Drain Type
FX2N-32MT-ESS/ULDiscontinued Replacement: FX3U-32MT/ESS Input: 16 points DC24V drain/source output: 16 points Transistor Source type
FX2N-32MT-E/UL Discontinued Replacement Model: FX3U-32MT/ES Input: 16 dots DC24V Drain Output: 16 dots Transistor Drain
FX2N-48MRDno longer replaceable: FX3U-48MR/ES Input: 24 points DC24V Drain Output: 24 points Relay
FX2N-48MR-ES/UL Discontinued Replacement: FX3U-48MR/ES Input: 24 points DC24V drain/source output: 24 points Relay
FX2N-48MSDno longer available Replacement Model: FX3U-64MS/ES Input: 24 dots DC24V Pan type output: 24 dots Thyristors
FX2N-48MS-E/UL Discontinued Replacement Model: FX3U-64MS/ES Input: 24 points DC24V Drain Output: 24 points Thyristor
FX2N-48MT Discontinued Replacement Model: FX3U-48MT/ES Input: 24 points DC24V Drain Output: 24 points Transistor Drain Type
FX2N-48MT-ESSS/ULDiscontinued replacement model: FX3U-48MT/ESS Input: 24 points DC24V drain/source output: 24 points transistor source type
FX2N-48MT-E/UlDiscontinued replacement model: FX3U-48MT/ES Input: 24 points DC24V drain output: 24 points transistor drain type
FX2N-64MR Discontinued Replacement Model: FX3U-64MR/ES Input: 32 points DC24V Drain Output: 32 points Relay
FX2N-64MR-ES/UL Discontinued Replacement: FX3U-64MR/ES Input: 32 points DC24V drain/source output: 32 points Relay
FX2N-64MSDno longer available Replacement Model: FX3U-64MS/ES Input: 32 points DC24V Drain Output: 32 points Crystal tube
FX2N-64MT Discontinued replacement model: FX3U-64MT/ES Input: 32 points DC24V drain output: 32 dots transistor drain type
FX2N-64MT-ESSS/ULDiscontinued Replacement Model: FX3U-64MT/ESS Input: 32 points DC24V drain/source output: 32 points Transistor Source type
FX2N-80MR Discontinued Replacement: FX3U-80MR/ES Input: 40 points DC24V Drain Output: 40 points Relay
FX2N-80MR-ES/UL Discontinued Replacement: FX3U-80MR/ES Input: 40 points DC24V drain/source output: 40 points Relay
FX2N-80MS Discontinued replacement model: FX3U-64MS/ES+FX2N-8EX+FX2N-16EYS Input: 40 points DC24V Pan type output: 40 points Thyristors
FX2N-80MT Discontinued Replacement Model: FX3U-80MT/ES Input: 40 dots DC24V Drain Output: 40 dots Transistor Drain
FX2N-80MT-ESSS/ULDiscontinued Replacement: FX3U-80MT/ESS Input: 40 points DC24V drain/source output: 40 points Transistor Source type
FX2N-128MRDno longer available replacement: FX3U-128MR/ES Input: 64 dots DC24V drain output: 64 dots Relay
FX2N-128MR-ES/ULDiscontinued Replacement: FX3U-128MR/ES Input: 64 dots DC24V drain/source output: 64 dots Relay
FX2N-128MTDno longer available for FX3U-128MT/ES Input: 64 dots DC24V drain output: 64 dots transistor drain
FX2N-128MT-ESSS/ULDiscontinued replacement model: FX3U-128MT/ESS Input: 64 points DC24V drain/source output: 64 points Transistor source type
FX2N-16MR-DSDobsolete replacement: FX3U-16MR/DS Input: 8 DC24V drain/source output: 8 relays
|
More on that
|
How to create a Mitsubishi CPU module project
Mitsubishi CPU module engineering creation method
Start engineering tools, create projects.
[Establishment process]
1. Select the CPU module to be used in the "Model" item. In the "Programming Language" project, select ...
|
|
Performance comparison of Mitsubishi servo motors
First, the control accuracy is different
The step angle of the two-phase hybrid Mitsubishi servo motor is generally 1.8 ° and 0.9 °, and the step angle of the five-phase hybrid Mitsubishi servo motor is generally 0.72 ° and 0.36 °. Mitsubishi servo motors are also smaller in some functions according to the segmentation. Such as Sanyo ...
|
|
The basic composition of Mitsubishi PLC
Mitsubishi PLC is composed of power module, CPU module, input module, output module and substrate.
Power module: Provides DC5V power supply for each module on the substrate.
CPU module: It is the heart of the PLC. The CPU module consists of ...
|
|
Classification of Mitsubishi touch screens
At present, Mitsubishi contact screens are generally divided into four categories: resistive contact screens, capacitive contact screens, infrared contact screens and surface acoustic contact screens Mitsubishi servo motors.
1. Resistive contact screen
The screen body of the resistive contact screen ...
|
|
The Mitsubishi iQ-F series is compatible with CC-Link IE TSN motion modules
The new iQ-F motion module is a controller that can perform advanced motion control such as positioning, synchronization, cam, speed, torque, etc., with a computing cycle of 500μs, and can be connected to a high-function servo amplifier through CC-Link IE TSN, making a higher contribution to the miniaturization and high functionality of the equipment.
...
|
|
The role of PLC power module - Mitsubishi
Internal memory programs, logic operations, sequential manipulation, punctuality, counting, arithmetic operations, and other programmable memories are used to manipulate a variety of machinery or production processes with digital or analog inputs/outputs. PLC-related peripherals should be easy to operate with industry to form a whole, easy to expand...
|
|
Performance comparison of Mitsubishi servo motors
First, the control accuracy is different
The step angle of the two-phase hybrid Mitsubishi servo motor is generally 1.8 ° and 0.9 °, and the step angle of the five-phase hybrid Mitsubishi servo motor is generally 0.72 ° and 0.36 °. Mitsubishi servo motors, which are also some functions, have a smaller step angle after segmentation.
...
|
|
Introduction to Mitsubishi tension controllers
1. Tension Manipulator Principle - Introduction
The tension manipulator can be called the tension manipulator, which is usually used with magnetic particle brake, magnetic particle clutch and tension detector, which is suitable for winding, unwinding, tension control, etc. It also has the so-called manual control function, which generally refers to the fact that human beings can ...
|
|
Manipulator Fault Repair - Mitsubishi Robot
1. Speak before you start
With regard to defective electrical equipment, it is necessary not to rush to start, but to inquire about the passage and defective phenomena that cause defects. For unfamiliar equipment, you should also understand the circuit principle and structural characteristics, and follow the corresponding rules. Before dismantling, it is necessary to fully understand each electrical department ...
|
|
Mitsubishi PLC command negation, empty operation and END, etc
Introduction to Mitsubishi PLC directives such as negation, air operation and END
The INV (Inverse) command is represented by a short 45° slash at the top of the ladder diagram, which negates the result of the operation before the execution of the instruction, and the result of the operation is 0 ...
|
|
Introduction to the functions of Mitsubishi's commonly used servo motor series
Mitsubishi servo motor MR-J2S series
1. The product also has RS-232 and RS-422 serial communication function, which can be used for parameter setting, trial operation, status display and gain adjustment through the personal computer installed with servo setting software.
2. Matching with MR-J2S series ...
|
|
Mitsubishi servo motor AL.50 alarm solution
During the operation of the Mitsubishi servo motor, it may be possible to display an AL.50 alarm under certain circumstances (such as after a period of continuous operation), what is going on? And how to solve it?
First of all, we need to know that the reason why the AL.50 alarm is presented is because the Mitsubishi servo ...
|
|
Mitsubishi PLC's method of controlling the inverter
1. Mitsubishi PLC's analog signal control inverter
Hardware: FX1N, FX2N PLC hosts, equipped with 1 simple FX1N-1DA-BD extended analog output board; or analog input-output hybrid module FX0N-3A; or FX2N-2DA with two outputs; or four outputs ...
|
|
Mitsubishi inverter pre-use debugging method
1. No-load energizing test of Mitsubishi inverter.
1. Ground the ground terminal of the Mitsubishi inverter.
2 Connect the power input terminal of the Mitsubishi inverter to the power supply through the leakage maintenance switch.
3 Check whether the factory display window of the Mitsubishi inverter is normal, if it is not correct.
|
|
Methods for shortening the scanning cycle of PLC programs – Mitsubishi
1. Try to avoid using "double words" when you can use "words", and try to prevent using real numbers when you can use integers.
2. Give priority to the use of surplus (other than hardware connection) IB, IW, ID, QB, QW, QD, followed by M and S;
3. Try to prevent the transformation of data types, ...
|
|
Mitsubishi servo motor is now commonly used
1. Torque control: Torque control is based on external simulation simulation type or direct address assignment to set the output torque of the motor shaft. For example, 10V matches 5Nm. When the external simulation simulation is set to 5V, the output of the motor shaft is 2.5Nm. If the load on the motor shaft is less than 2.5Nm, ...
|
|
Mitsubishi FX1N switching power supply fault repair
Problem description: The power supply of the Mitsubishi FX1N-60MR-001 has no display (the safety guard, filter, temperature protection element, and rectifier are damaged).
Inspection and repair: After the PLC is connected to the power supply, the power indicator (POWER light) does not light up.
|
|
Mitsubishi Electric develops technology for high-power-density converters with embedded components
TOKYO, March 25, 2020 – Mitsubishi Electric Corporation (TSE: 6503) today announced that it has developed a new technology that integrates power devices, passives, sensors, and other embedded components on the same substrate and performs the dispensing at 100kW (continuous) power.
|
|
Mitsubishi inverter FR-E700 series is selected
Q: When will I choose the E740 series inverter?
A: E700 is an economical and small inverter with high driving performance, with the function of holding the brake, and can also add options to expand the function, which can be used for transportation, lifting occupations, and has high cost performance.
Q: Mitsubishi inverter E740 should ...
|
|
Mitsubishi PLC adjusts the built-in time
1. TWR (Time Write) command
Write the time preset value to the built-in real-time clock: Clock information is written to the TWR (Time Write) command. The sequence number of the action instruction is FNC167, [S ·] T, C and D can be used, and only 16-bit operations can be used, accounting for 5 program steps.
The work of the directive ...
|
|