Power semiconductor module for 40kW class commercial air conditioner
Expansion of the "6th Generation 1200V Large DIPIPM" product lineup
On August 30, Mitsubishi Electric Corporation will release a new product in the 6th Generation 1200V Large DIPIPM TM series of power semiconductor modules that drive inverters for commercial air conditioners such as commercial air conditioners, including 7/1200V products.
6th Generation 1200V Large DIPIPM (7***/1200V)
Features of the new product:
1. Equipped with the 7th generation IGBT chip, suitable for large-capacity commercial air conditioners equipped with CSTBTTM; The 7th generation IGBT is constructed to achieve the rated current; Carrier storage trench gate bipolar transistor
2. Ensure compatibility with conventional products, and contribute to the planning of the inverter system to standardize the overall size, pin equipment, etc. with the company's large-scale packaging; The product series is compatible with BSDs with built-in current-limiting resistors, reduces the number of external components, optimizes internal circuitry, improves temperature detection accuracy, and simplifies heat dissipation planning
This product is a product of the PS22A7x series of 1200V large DIPIPM Ver.4 and the PSSxxSA2FT series of 1200V large DIPIPM Ver.6
Boot-strap diode: A bootstrap diode used to generate other voltages from a reference voltage
|
More on that
|
Installation and maintenance of Mitsubishi inverters
1. Mitsubishi inverter is more and more widely used because of a series of advantages such as wide speed regulation range, high speed regulation accuracy, fast dynamic response, high work efficiency, convenient operation and easy interface with other equipment. Because of the high common sense content of Mitsubishi inverter and the messy technology, how to use Mitsubishi inverter well...
|
|
Mitsubishi inverter fault judgment method
1. UVT problem
UVT is an under-voltage problem, and I believe that many customers will still encounter such problems in use.
The common undervoltage detection point of Mitsubishi inverter is the voltage on the DC bus side, and a low voltage value is sampled after the voltage division of the large resistance resistor, which is compared with the standard voltage value ...
|
|
Mitsubishi Electric begins research and development of a Mars satellite probe probe
TOKYO, February 21, 2020 – Mitsubishi Electric Corporation (TOKYO:6503) announced today that it has been appointed by the Japan Aeronautics and Astronautics Agency (JAXA) as the contractor for the Mars Lunar Probe (MMX) space probe. Mitsubishi Electric has launched development activities for the project that will utilize MMX's system ...
|
|
Mitsubishi PLC encryption process
The encryption process is as follows:
** Open the serial port for the first time
[00000000] IOCTL_SERIAL_SET_BAUD_RATE Baud Rate: 9600 (Set baud rate here)
[00000000] IOCTL_SERIAL_SET_LIN ...
|
|
Mitsubishi low-power Z024 series inverter failure OC cause
(1) Aging of the drive circuit
Due to the use of a long period of time, it will inevitably lead to the aging of components, which will cause the drive waveform to be distorted, and the output voltage will be unstable, so OC alarm will often appear as soon as it is running.
( ...
|
|
The cause of the failure caused by OC - Mitsubishi inverter
1. Aging of drive circuit
Due to the long-term use, it will inevitably lead to the aging of components, and then cause the drive waveform to be distorted, and the output voltage will be unstable, so OC alarm often appears as soon as it is running.
...
|
|
Mitsubishi PLC keeps the circuit written
There is a very common kind of circuit in Mitsubishi PLC - the persistence circuit. The holding circuit means that when the external input switch is a button, it can press the button through the holding circuit to insist on the output, similar to the self-locking in the electrical diagram. We use Mitsubishi PLC as an example to write a sticking circuit.
...
|
|
Mitsubishi PLC hardware installation method
1. Use the special crimping pliers for network cable to crimp one end of the cable and the RJ45 crystal head; The other end is connected to the FX2N-485-BD communication template according to the method shown in Figure 1-Figure 3, and the two unused P5S terminals are not connected.
2. Open the panel cover on the left side of the PLC host, and put the FX2N-485-BD communication module ...
|
|
PLC circuit debugging precautions - Mitsubishi
1. For the switching input and output circuits, pay attention to the consistency criterion of maintaining the state; The positive logic criterion is usually used, that is, when the input and output are live, it is in the "ON" state and the data value is "1"; Conversely, when the input and output are powered off, it is in the "OFF" state and the data value is "0". Such...
|
|
Which components in the Mitsubishi inverter need to be replaced regularly
Mitsubishi inverter is composed of many electronic parts, such as semiconductor components, etc., in the application and protection involves the replacement of a related component, because of the composition or physical characteristics of the inverter, in a certain period of time will deteriorate, thus reducing the characteristics of the inverter, is ...
|
|
Performance comparison of Mitsubishi servo motors
First, the control accuracy is different
The step angle of the two-phase hybrid Mitsubishi servo motor is generally 1.8 ° and 0.9 °, and the step angle of the five-phase hybrid Mitsubishi servo motor is generally 0.72 ° and 0.36 °. Mitsubishi servo motors, which are also some functions, have a smaller step angle after segmentation.
...
|
|
How to deal with Mitsubishi PLC failures - Mitsubishi
01. Base system problem
In Mitsubishi PLC, binary, octal, decimal 10, hexadecimal, 2-10 (BCD), etc., we need to master the conversion of 2-8 base.
2-8, the binary number is remembered from the back, every 3 dividends in a group, each group is separated into 8 bases, such as 1 ...
|
|
Mitsubishi Electric will introduce the T-series 2.0kV IGBT module for industrial use
Tokyo, June 9, 2021 – Mitsubishi announced the upcoming launch of its industrial T-series 2.0kV insulated gate bipolar transistor (IGBT) module, the world's first IGBT1 with a 2.0kV withstand voltage, June 30. This module is ideally suited to increase the power of renewable energy power converters ...
|
|
Mitsubishi AnS series analog module bias and gain applications
In today's industrial field, when using analog-to-digital conversion or digital-to-analog conversion, most of them do not only use the standard input characteristics of -10V-+10V, 0-20mA, but according to the practical voltage and current values to do the process requirements, then it is necessary to do the AD or DA module ...
|
|
The Mitsubishi QnUDVCPU module records the write function of the settings
The models of QnUDVCPU series products are Q03UDVCPU, Q04UDVCPU, Q06UDVCPU, Q13UDVCPU, and Q26UDVCPU.
Data logging settings can be written to the target memory of the Mitsubishi QnUDVCPU module. When writing data recording settings, you should write data in the purpose of the writing settings.
|
|
Mitsubishi Electric Solutions serves the entire process of lithium battery production
Mitsubishi Electric's MES system MELNAVI has a standard database, which can meet the needs of the 11 major functions required by MES, and also supports flexible secondary development, which can easily connect the upper ERP and lower automation products in a short time, and can also be connected to other APS scheduling software and analysis systems. ...
|
|
Mitsubishi Q Series PLC and GX Works2 connection method
01 USB connection
USB connection requires a device USB driver, generally after installing GX Works2 software, it will automatically install the driver, but a single time due to antivirus software or system reasons, may not be installed, then we need to manually drive the device to the accounting machine. The specific device method we ...
|
|
Mitsubishi FR-A840 series inverter is coming "strong".
Mitsubishi Electric Automation Corporation has launched the A800 Series Integrated Inverter Drive (VFD) for fast, reliable, easy-to-use, and easy integration and installation for occupational demand drives. The A800 series variable frequency drive combines traditional induction and permanent magnet vehicles into a single solution that supplies ...
|
|
Performance comparison of Mitsubishi servo motors
First, the control accuracy is different
The step angle of the two-phase hybrid Mitsubishi servo motor is generally 1.8 ° and 0.9 °, and the step angle of the five-phase hybrid Mitsubishi servo motor is generally 0.72 ° and 0.36 °. Mitsubishi servo motors are also smaller in some functions according to the segmentation. Such as Sanyo ...
|
|
Mitsubishi PLC Comparison Instruction Application
1. Compare the instruction CMP
1)。 16-bit arithmetic (CMP, CMPP) compares the contents of the comparison value S1 with the comparison source S2, and according to the results (small, - zhi, large), D, D+1, D+2 - one is ON.
...
|
|