1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment, sensors and drive equipment, which is the lowest layer of the entire network system. The CC-Link fieldbus connection greatly reduces the number of wirings and improves the maintainability of the system. In addition, not only the data of switching quantities such as ON/OFF, but also intelligent equipment such as ID systems, barcode readers, inverters, and human-machine interfaces can be connected, and the operation efficiency of maintenance can also be greatly improved from the communication of various data to the handling of terminal production information. When used in Q series PLCs, CC-Link has better functions and is easier to use.
2. The control layer/MELSECNET/10 (H) is the middle layer of the entire network system, which is a control network for convenient and high-speed processing data exchange between PLC, CNC and other control equipment. MELSECNET/10, as a MELSEC control network, has won high reviews for its outstanding real-time performance, simple network settings, program-free network data sharing concept, and redundant loops, and the number of devices used is the highest in Japan and few in the world. MELSECNET/H not only inherits the excellent features of MELSECNET/10, but also makes the network more real-time and has a larger data capacity, which further adapts to the needs of shopping malls.
3. The information layer/Ethernet (Ethernet) information layer is the highest level in the network system, which is mainly used to transmit production management information, quality management information and equipment operation data between PLC, equipment controller and production management PC, and the information layer uses the most common Ethernet. It can not only connect to Windows PC, UNIX system operation station, etc., but also to connect to various FA equipment. The Ethernet module of the Q series PLC series has the increasingly ubiquitous Internet e-mail sending and receiving function, and the user can easily send and receive production information e-mails anywhere in the world, and build a long-distance supervision and management system. Together, the FTP server function of the Internet and the MELSEC protocol make it easy to upload/download programs and transfer information.
In addition, in addition to the above-mentioned networks, the Q series PLC can also support the networks of other manufacturers such as Profibus, Modbus, Devicenet, ASi, etc., and can also carry out serial communication such as RS-232/RS-422/RS-485, and carry out data transmission and other communication methods through data lines and telephone lines.
When communicating in Mitsubishi's PLC network, there is no difference in network types and continuity, and data communication between networks and long-distance monitoring, modification, and debugging of programs can be carried out regardless of the level and type of network. MELSECNET/H and CC-Link use a cyclic communication method to send and receive messages automatically and periodically, without the need for a special data communication program, only a simple parameter setting. MELSECNET/H and CC-Link use the broadcast method for circular communication transmission and reception, so that data can be shared on the network. The Ethernet, MELSECNET/H, CC-Link networks used in Q Series PLCs can be easily set for network parameters and various functions on the GXDeveloper software screen.
|
More on that
|
Query Error Code Method – Mitsubishi
Error Number (D8063): 6314
ERROR MESSAGE: PARALLELLINKERROR (PARALLEL OPERATION COMMUNICATION ABNORMAL)
Error content: Parallel operation string abnormal
Method: Whether the power supply of the two PLCs is on, and whether the connection wires between the main machine and the parallel operation module are correctly connected ...
|
|
Advantages of Mitsubishi Electric fresh air system
Mitsubishi Electric's fresh air system realizes indoor ventilation, but of course, we can't just replace the outdoor air into the room, a good fresh air should filter the harmful substances in the air, so that the air entering the room is not only fresh, but also clean and harmless.
...
|
|
The relationship between torque and performance of Mitsubishi servo motors
1. Additional torque
The torque that occurs on the motor shaft under additional voltage, extra load is called the extra torque of the motor.
2. Starting torque
The torque generated by the motor at the moment when a voltage is applied to the motor in a stopped condition is called the starting torque. The starting torque characterizes the electrical...
|
|
Mitsubishi low-power Z024 series inverter failure OC cause
(1) Aging of the drive circuit
Due to the use of a long period of time, it will inevitably lead to the aging of components, which will cause the drive waveform to be distorted, and the output voltage will be unstable, so OC alarm will often appear as soon as it is running.
( ...
|
|
What is the difference between the Mitsubishi PLC FX3U and FX5U
1. The speed of the system bus is different. Although the FX5U series is small but precise, compared with the previous product FX3U, the system bus speed is greatly increased by 150 times, and the maximum expansion module can be expanded by 16 intelligent expansion modules, built-in 2-in and 1-out analog functions, built-in Ethernet interface and 4-axis 200kHz high-speed positioning function.
...
|
|
Mitsubishi servo system failure problem
The origin position is incorrect, and the encoder debugs/zeros the bit
Replacement bearings, bearing groove wear, rotor cracking, shaft cracking
Gear groove wear
The magnet bursts steel, the magnet falls, gets stuck and doesn't move
Encoder wear, code ...
|
|
Mitsubishi Electric begins research and development of a Mars satellite probe probe
TOKYO, February 21, 2020 – Mitsubishi Electric Corporation (TOKYO:6503) announced today that it has been appointed by the Japan Aeronautics and Astronautics Agency (JAXA) as the contractor for the Mars Lunar Probe (MMX) space probe. Mitsubishi Electric has launched development activities for the project that will utilize MMX's system ...
|
|
Introduction to Mitsubishi tension controllers
1. Tension Manipulator Principle - Introduction
The tension manipulator can be called the tension manipulator, which is usually used with magnetic particle brake, magnetic particle clutch and tension detector, which is suitable for winding, unwinding, tension control, etc. It also has the so-called manual control function, which generally refers to the fact that human beings can ...
|
|
Mitsubishi PLC main maintenance and overhaul content points
The main content of the protection and maintenance of Mitsubishi PLC
Although the failure rate of PLC is very low, the control system composed of PLC can operate stably and reliably for a long time, and it is essential to protect and view it alone. Generally, every six months ...
|
|
Troubleshooting methods for Mitsubishi overload
1. Check whether the motor is heated
If the temperature rise of the motor is not high, the first thing to check is whether the electronic thermal protection function of the Mitsubishi inverter is preset reasonably, if the Mitsubishi inverter still has margin, the preset value should be relaxed; For example, the allowable current of Mitsubishi inverter is now out of margin, not ...
|
|
Mitsubishi is a method for completing the modification of timer setting outside the PLC
In the process of using the PLC control system, it is often necessary to correct some parameters, and the most common is to correct the set value of the timer. In order to facilitate the operator to correct the set value of the timer, the following methods can be used:
1. The use of man-machine ...
|
|
Mitsubishi takes instructions and outputs instructions
1) LD (take instruction) A command to connect a normally open contact with the left bus, and every logic line that starts with a normally open contact is used with this instruction;
2) LDI (Reverse Instruction) A normally closed contact is connected to the left bus to the instruction, each ...
|
|
Capacitive action in Mitsubishi inverters
Introduction to the names and effects of capacitors in different circuits
Capacitor is a kind of energy storage element, with the characteristics of "straight through AC, low frequency through high frequency", people in order to know and identify the capacitor in different circuits, according to its effect in the line and give it many names, understand ...
|
|
Explanation of Mitsubishi pIc source type and drain type
The source type is the power supply of the device, which has an input drive source and an output point with a power supply; Drain type means that the device does not have its own power supply, and the drive of the input point requires an external power supply, and the output is only a passive contact signal.
The general input points are ...
|
|
PLC Reasonable Programming to Eliminate Misoperation - Mitsubishi
(1) Eliminate finger tremor: use the differential instruction DIFU (13) to retrieve the rising edge of the button to send the electrical signal, and the PLC only executes it once in an execution cycle, and then prevent such misoperation;
(2) Unconscious operation:
(1) Optimize the display function and use different fingers...
|
|
Mitsubishi inverter capacity and capacity selection
The capacity (non-functional) of the Mitsubishi inverter for the drive motor can be understood from the change in energy flow determined by the operation method.
1. When accelerating or operating at constant speed
The efficiency of the inverter is the output current, that is, ...
|
|
Mitsubishi A800 series inverter realizes motor self-learning
Set it up as follows:
Press PU/EXT to switch to PU format
Pr.9 = additional current of the motor
Pr.71=3 (ordinary motor) or 13 (constant torque motor)
Pr.80 = motor power
Pr.81 = number of poles of the motor ( ...
|
|
Features of Mitsubishi PLC commonly used models
FX Series PLC: FX3G PLC has a built-in large-capacity program memory, 32K steps, and the basic instruction processing speed can reach 0.21μs in specification mode. In the meantime, the FX series 5U is suitable for any industry, and is used by small and medium-sized enterprises. For example, this year's very popular mask machine is suitable for FX5U, and he can ...
|
|
The difference between Mitsubishi PLC source type and leak type
Mitsubishi PLC split source type (PNP) or drain type (NPN), here are their differences
1: Leakage logic: When the current flows out of the signal input terminal, the signal becomes ON, which is leakage logic. The current flows through the terminals and has the output characteristics of an NPN transistor.
2: Source logic: When ...
|
|
Low-voltage electrical faults and maintenance methods - Mitsubishi
In the process of operation, low-voltage electrical appliances will present problems due to improper use or long-term operation of aging components, and there are many kinds of problems, and the common problems are analyzed and dealt with.
1. Contact problems and repairs
The contact is the primary component of the low-voltage switching coupon, ...
|
|