1. The shield wire should be as close as possible to the low potential end, which can be understood in this way, generally we think that the ground potential is "0", and in reality, if there are two grounding terminals, there will be a potential difference between the two grounding terminals at a certain time, and there will be a current between the two wires, which is also a kind of disturbance.
2. In actual use, if the place where the control cable passes through is more complex and requires multi-end grounding, we generally take to cut the shielding layer and then ground in different places. This method is also often used for the grounding of the communication cable shield of the control equipment of the factory.
|
More on that
|
At the physical level, the stable operation of the inverter is guaranteed-Senlan inverter
For the most popular electrical control equipment inverter (Variable-frequency Drive, VFD), as a precision electronic industrial control equipment, in order to run smoothly for a long time, we, as professional and technical personnel, need to be on the VFD device or before the operation.
|
|
The reason why the frequency of the inverter cannot be adjusted - Senlan inverter
If there is no damage to the hardware, the maximum torque output of the inverter is generally less than the load to increase the torque.
The acceleration time is too short
...
|
|
Sunland inverter electromagnetic interference suppression method
When the peripheral equipment and the inverter share the same power supply, the disturbance generated by the inverter is transmitted against the power line, which will cause other equipment in the same system to malfunction. The following methods can be adopted:
(1) The input device of the inverter is equipped with an EMI filter or a ferrite common-mode filter (magnetic ring) ...
|
|
What are the peripheral equipment for inverter selection - Senlan inverter
After the inverter selection is completed, it is necessary to consider whether other peripheral equipment needs to be equipped according to the actual situation of the site. The peripheral equipment for frequency converter selection mainly includes circuit breakers, reactors, contactors, braking resistors, etc.
1. Circuit breaker
...
|
|
Rapid selection method of low-voltage inverter - Sunland inverter
First, according to the classification and selection of inverters
1. Inverters can be divided into general-purpose inverters and special inverters.
2. General-purpose inverters are mainly used in: general fan pumps (referring to inverters that only drag a single fan or pump) loads, mechanical loads, and loads requiring high overloads.
|
|
The reason for the explosion of the inverter module - Senlan inverter
1. Condensation The temperature difference in the workshop is large, and the inside of the inverter presents condensation.
2. Impact load. The load fluctuates greatly, and the output current of the inverter suddenly increases, resulting in module damage.
3. The inverter is overloaded in the start, ...
|
|
Inverter parameter setting method - Senlan
1. Control method:
i.e. speed control, rotation control, PID control, or other methods. After the control method is adopted, it is generally necessary to carry out static or dynamic identification according to the control accuracy.
2. Minimum operating frequency:
That is, the minimum speed of the motor operation, the motor at low speed ...
|
|
Hope for an application example of Sunland inverter
Industrial process control: It is expected that Sunland inverters are widely used in industrial process production control, such as conveyors, tugboats, air compressors, pumps, and fans and other equipment in various control systems.
Mechanical control: It is expected that Sunland inverters are widely used in mechanical control, such as ...
|
|
Inverter braking resistance connection method - Senlan inverter
If the drive has a built-in braking unit and additional braking resistors, it is important to pay attention to the correct wiring of the braking resistors. The braking resistor should be connected between the P terminal and the DB terminal, but not between the P terminal and the N terminal, otherwise the three-phase rectifier bridge will operate at full load when it is not running, resulting in the equipment can not be ...
|
|
Motor encoder and rotor pole phase zero alignment repair - Sunland
1. Phase alignment method of incremental encoder
The alignment between the phase of the UVW electronic transmutation signal and the phase of the rotor pole, or the phase of the TV spot, of the incremental encoder with the signal exchange is as follows:
1) Use a DC power supply to pass the UV winding of the motor to less than the amount of ...
|
|
The reason for adding a frequency converter to the crane control system - Senland
Prior to the introduction of frequency converters, overhead crane operators operated the cranes using contactor-based controls. For low-cycle cranes, the system is equipped with a single or two-speed motor. For cranes with higher load cycles, they use so-called wound rotor motors.
...
|
|
The key points of the use of inverter - Sunland inverter
In order to ensure the safe, efficient and reliable operation of the inverter, the following keys should be grasped when using the inverter:
1) It is necessary to reliably ground the grounding terminal of the inverter, so as to effectively press the radio frequency disturbance and enhance the reliability of the system.
|
|
Sunland won the "well-known brand of China's domestic inverter" for the fifth time in a row
On April 15, 2011, the "Century Tour of China's Automation Industry (CAIE2011)" was held in Beijing, and Sunland inverter was once again re-elected as "China's well-known brand of domestic inverter". Dr. Chen Bin, President of Continental Hope Group and Chairman of Hope Sunland Technology Co., Ltd., personally ...
|
|
Sunland SB200 37KW inverter does not show analysis
After inspection, the circuit board of the machine is composed of a fan switching power supply board, a control board with a switching power supply and a driving board, etc., the fan power supply and the control board working power supply are independent of each other, the fan power supply output is normal, and the control board working power supply has no output due to failure.
...
|
|
Senlan SV1000 servo drive check before power-on
1) Oil circuit inspection: Open the safety valve to check whether there is any leakage in the oil circuit.
2) Line check: whether the R, S, T, PE on the input side of the driver, U, V, W, PE lines on the output side and the control line are corresponding.
3) Check whether the power supply voltage of the incoming terminal of the servo drive is normal ...
|
|
Sunland inverters are designed for environmental requirements
1. The ambient temperature ---- is generally "-10-+40°C"; Derating between 40 and 50°C, the additional output current must be reduced by 1% for every 1°C increase. If the ambient temperature is too high and the temperature changes greatly, the insulation of the inverter will be greatly reduced, which will affect the life of the inverter.
...
|
|
Quickly determine whether the inverter used is suitable - Sunland inverter
First of all, we need to understand a truth, that is, many times the good and bad of things are relative. The variable frequency drive (VFD) is used as a power source to drive the operation of the motor, and its fundamental role is to regulate the speed. If the wiring is normal, the parameters are reasonable, and the load is not ...
|
|
Hope Senlan inverter control panel button function diagram
Hope Senlan inverter control panel button function diagram
1. The "FUNC/DATA" button is a programming key, press this button once to convert the operation mode, and press it again to read and write the utility code.
2."S ...
|
|
Industrial control circuit board capacitor damage fault characteristics and maintenance - Senlan
Capacitor damage is the highest problem in electronic devices, especially electrolytic capacitors.
Capacitor damage is manifested in: 1. Capacity becomes smaller, 2. Capacity is completely lost, 3. Leakage, 4. Short circuit.
Electricity...
|
|
The difference between inverter and inverter power supply - Senlan inverter
What is an inverter power supply? A variable frequency power supply converts the alternating current from the main power supply from AC→DC→AC to a pure sine wave. The output frequency and voltage can be adjusted within a specific range. Unlike the inverter governor used for the speed control of electric motors, it is also different from the general AC power supply. Aspiring AC ...
|
|