After the inverter selection is completed, it is necessary to consider whether other peripheral equipment needs to be equipped according to the actual situation of the site. The peripheral equipment for frequency converter selection mainly includes circuit breakers, reactors, contactors, braking resistors, etc.
1. Circuit breaker
The circuit breaker can easily control the power-off and closure of the circuit. It is mainly used to automatically disconnect the power supply when the frequency conversion system produces re-reverse current, overcurrent, short circuit and undervoltage, so as to play an isolation role and maintain the power supply.
2. An electric scrambler
The reactor is a commonly used peripheral equipment in the selection of frequency conversion. When the interval between the inverter and the motor is too long, or the inverter and the power supply are too close, in order to improve the power factor and reduce the inrush current in the input to a minimum, a DC reactor or AC reactor must be added in the inverter selection process.
3. a contactor
Contactors are divided into input contactors and output contactors. When a component of the frequency conversion system fails, the power supply is automatically blocked to prevent the equipment from being burned out at a remote interval.
4. Brake resistance
When the general inverter is applied to inertial loads such as CNC machine tools and elevators, the inverter selection needs to use braking resistors to consume the remaining energy in the inverter system.
|
More on that
|
Automatic gain adjustment part - Sunland inverter
In fact, there are also options for automatic gain adjustment, which generally divide the control response into several levels, such as high echo, medium echo, and low echo, which can be set by the user according to actual needs.
Azimuth Share Buff:
1. Set the share gain of the azimuth ring adjuster;
2 ...
|
|
The control mode of low-voltage general-purpose inverter - Sunland inverter
Voltage Space Vector (SVPWM) Manipulation Method:
It is based on the premise of the overall generation effect of the three-phase waveform, with the intention of approximating the ideal circular rotating magnetic field trajectory of the motor air gap, generating the three-phase modulation waveform at one time, and controlling it by approaching the circle with inscribed polygons. In practice, ...
|
|
The correct wiring of the rail power supply
The rail-rail power supply is a kind of switching power supply that is installed through the rail-type device, which is mainly used to monitor the voltage, current, temperature and other different aspects of the equipment, so that it can play a good maintenance effect. This switching power supply has a variety of different characteristics such as small size and light weight, ...
|
|
Sunland's measures to reduce inverter failure
According to the test, the service life of the inverter is halved for every 10°C increase in the operating ambient temperature. For this reason, in daily use, a reasonable maintenance cycle and guidelines should be formulated according to the actual operating environment and load characteristics of the inverter.
|
|
Misunderstandings and countermeasures of industrial control inverter - Senlan
Today, with the rapid development of science and technology, with the continuous improvement of industrial automation, inverters have also been widely used. Choosing a suitable inverter is very important to ensure the normal and efficient work of the inverter, but in practice, it is necessary to pay attention to some ...
|
|
Learn the way of inverter - Senlan inverter
The inverter is an essential accessory in industrial use, and its main function is to regulate the speed of the motor. It is widely used in various equipment such as production F-line and machine tools. Many engineering people have touches.
The functions of the inverter are many, the parameters are complex, and it is difficult to play without professionals. ...
|
|
The connection method of three-phase isolation transformer - Senland
The three-phase barrier transformer adopts a three-phase double-winding structure, which has the characteristics of lightning protection and anti-disturbance. Each winding on the primary and secondary sides is divided into two coils, which are wound from two layers of metal foil insulated from each other. So there is capacitance C (capacitance barrier transformer) between the two coils. Then, being able to ...
|
|
The cause of leakage of the inverter-controlled motor - Senlan
In some fields, the use of inverter to control the motor will present the problem of leakage, and the leakage voltage ranges from tens of volts to 200 volts.
According to the inverter control motor ...
|
|
Advantages of Sunland HOPE530 series inverter
Sunland HOPE530 series inverter is a high-performance, high-reliability intelligent controller, widely used in a variety of industrial occasions. It is easy to operate, diversified equipment and high quality, and has become one of the intelligent power control equipment trusted by users.
...
|
|
Overvoltage treatment method caused by load input side - Senland
(1). The deceleration time of the frequency conversion parameter is increased or free parking is adopted
Assuming that the overpressure phenomenon is present in the parking process, the process has no parking requirements for the parking time or direction, and the deceleration time can be increased appropriately. The reason for the overvoltage in the parking process is that after the frequency conversion announces the deceleration command, the motor ...
|
|
Sunland inverter wiring standard
It is necessary to separate the signal line from the power line: when using analog signals for long-distance control of the inverter, in order to reduce the disturbance of the analog amount from the inverter and other equipment, please separate the signal line of the control inverter from the strong current circuit (main circuit and sequential control circuit). Inverter ...
|
|
The connection method of the shielded wire adheres to the principle - Senlan inverter
1. The shield wire should be as close as possible to the low potential end, which can be understood in this way, generally we think that the ground potential is "0", and in reality, if there are two grounding terminals, there will be a potential difference between the two grounding terminals at a certain time, and there will be a current between the two wires, which is also a kind of agitation.
|
|
Damage and repair of internal electronic components of the inverter - Hope Sunland
1. Repair the damage of the inverter rectifier block
The damage of the inverter rectifier bridge is also one of the common faults of the inverter, the inverter rectifier block in the early production is mainly diode rectifier, and now some rectifier blocks choose the rectifier mode of thyristor (voltage regulation and frequency modulation inverter).
Middle...
|
|
Suppression method of electromagnetic interference of inverter - Sunland inverter
The operating principle of the inverter determines that it will have a certain disturbance, which may bring EMC (electromagnetic compatibility) problems to the equipment or system, and the inverter, as an electronic device, will also be affected by external electromagnetic disturbance.
Below...
|
|
Precautions for the use of industrial touch screen all-in-one machine
1. The contact screen all-in-one machine adopts the new contact identification technology, and the user only needs to touch it lightly on the contact screen without passing the pressure sensing to complete the operation. Care must be taken not to use too much force or sharps to scratch the surface of the contact screen.
...
|
|
Control the hovering function operation and principle of the inverter - Sunland inverter
How does the hovering function of the inverter work?
When the speed of the asynchronous motor is 0, the encoder response is meaningless, and it needs to be converted to V/F control, and the frequency is set to 0; The voltage is set to 0 speed at which the motor promises to withstand the current at the moment ...
|
|
The reason why the inverter damaged the motor - Senlan
The presentation of inverters has brought a revolution to industrial automation control and motor energy saving. Industrial production is simply inseparable from the inverter, even in the daily livelihood, elevators, inverter air conditioning has become a part of the insistence, inverter from the beginning into all corners of production, subsistence. However...
|
|
Anti-interference measures in the application of Sunland inverter
The main manifestations of the disturbance of the inverter in the application are: higher harmonics, noise and oscillation, load matching, heat generation and other problems. These disturbances are unavoidable, because the input part of the inverter is a rectifier circuit and the output part is an inverter circuit, both of which are made up of nonlinear components that play a switching effect.
|
|
Inverter control motor speed method - Senlan
1. Why can the rotation speed of the motor be changed freely?
The unit of motor rotation speed: r/min the number of rotations per minute, can also be expressed as rpm.
Example: 2-pole motor 50Hz3000 [r/min]
4-pole motor 50Hz1500[r/min]
Conclusion: The rotation of the motor ...
|
|
Ensure the normal operation of the inverter in a humid environment
Due to the heavy rain and humidity in some areas recently, in order to avoid long-term power failure and the impact of wetting on the inverter, the following points can be used as various precautions before customers resume production:
1. Look inside the electrical cabinet, e.g. ...
|
|