1) Oil circuit inspection: Open the safety valve to check whether there is any leakage in the oil circuit.

2) Line check: whether the R, S, T, PE on the input side of the driver, U, V, W, PE lines on the output side and the control line are corresponding.

3) Check whether the power supply voltage of the incoming terminal of the servo drive is normal (380V, no phase loss, and the voltage amplitude is correct).

                               Senlan SV1000 servo drive check before power-on

4) Computer output viewing: power the injection molding computer separately, do not start the servo drive, check the output of pressure and flow (flow command 0% - 99%, corresponding to output 0 - 10V; Pressure command 0% - 99% corresponds to output 0 - 10V).

5) Check whether the drive parameters are set correctly.

After the wiring and power supply check to confirm that it is correct, close the air switch of the AC power supply on the input side of the driver, power on the driver, and the driver operation panel will display "8.8.8.8.8.8.8", when the contactor inside the driver is properly engaged, the LED digital tube display character changes to a given frequency, indicating that the driver has been initialized to the end. If there is an abnormality in the power-on process, please disconnect the air switch on the input side to check the cause and rule out the abnormality.

More on that
I/O (Input/Output) Selection – Senland I/O (Input/Output) Selection – Senland

In the 90s of the 20th century, PLC has formed a variety of PLCs: micro, small, medium, large and giant. According to the number of I/O points, it can be divided into five types: micro PLC (32 I/O), small PLC (256 I/O), medium PLC (1024 I/O), large PLC (4.69 I/O), and giant PLC (8195 I/O). ...

Heat dissipation method of small-capacity inverter - Senlan Heat dissipation method of small-capacity inverter - Senlan

Natural heat dissipation methods are generally used for heat dissipation of small-capacity inverters, because their operating environment should be well ventilated and free of dust and floating objects. The dragging objects of this type of inverter are mostly household air conditioners, CNC machine tools, etc., and the power is small. ​ ...

Senlan inverter selection points Senlan inverter selection points

1. Select the inverter according to the load characteristics, such as the load is constant torque load, you can choose Siemens MM440 inverter, ABB ACS800 series inverter, etc.; If the load is a fan or pump load, you can choose Siemens MM430 inverter, ABB ACS510 series inverter, etc. 2、 ...

The basic requirements of VFD installation design - Sunland inverter The basic requirements of VFD installation design - Sunland inverter

(1) The VFD should be installed in the control cabinet. (2) The VFD is best installed in the center of the control cabinet; The VFD It should be vertically installed with the top and bottom protected from large parts that may obstruct the exhaust and intake. (3) VFD control cabinet or partition, or the upper and lower parts of the necessary device ...

How to expand the application range of inverter - Sunland inverter How to expand the application range of inverter - Sunland inverter

In the electrical profession, the use and development of energy-saving frequency conversion is very good, which has promoted the electrical profession to reach the pinnacle of science and technology again. Frequency converter (VFD) has a very good development shape in China, but it still has to withstand various tests. As long as you give full play to your professional advantages, you can gain a firm foothold in this society. VFD ...

What is the energy feedback of the inverter - Senlan inverter What is the energy feedback of the inverter - Senlan inverter

The essence of energy feedback is active inverter, and the realization method of energy feedback of general inverter is to feed renewable energy to the grid with an anti-parallel three-phase inverter at the uncontrolled rectification of the pre-stage of the general inverter. The main circuit of the energy feedback equipment is mainly composed of thyristors, IGBTs and IPM modules.

Hope Sunland launched the new Hope800 series inverter Hope Sunland launched the new Hope800 series inverter

Hope Sunland Technology Co., Ltd. is a national key high-tech enterprise dedicated to the research and development of high, medium and low voltage frequency conversion technology and the design, development, production, sales and service of related products.

Solve the inverter fault method - Sunland inverter Solve the inverter fault method - Sunland inverter

Motherboard faults are often manifested as faults that are difficult to visually identify, such as system startup failure and screen invisibility. You can use a brush to gently brush off the dust on the motherboard, in addition, some plug-in cards and chips on the motherboard are in the form of plugs.

The reason for adding a frequency converter to the crane control system - Senland The reason for adding a frequency converter to the crane control system - Senland

Prior to the introduction of frequency converters, overhead crane operators operated the cranes using contactor-based controls. For low-cycle cranes, the system is equipped with a single or two-speed motor. For cranes with higher load cycles, they use so-called wound rotor motors. ...

Sunland inverter maintenance and cleaning inspection method Sunland inverter maintenance and cleaning inspection method

There are many special faults, which come and go, looming, making it impossible to judge and deal with. At this time, you can clean the circuit board with water or alcohol, and brush off the dust and rust on the circuit board with a soft brush, especially pay attention to the solder joints are dense, and the circuit near the 0 volt copper layer is also ...

The inverter is different from the inverter power supply - Senland The inverter is different from the inverter power supply - Senland

In terms of power supply, everyone may know that the inverter and the inverter power supply are auxiliary equipment for charging electrical appliances, but many people do not know what is the inverter power supply and what is the inverter. With the continuous progress of the times, electrical appliances will be constantly updated, and auxiliary equipment is constantly changing.

Introduction to the main series of Sunland inverter products Introduction to the main series of Sunland inverter products

SB150 SB150 is a delicate and practical inverter launched by Sunland, with exquisite and delicate appearance, exquisite and perfect circuit, simple and practical function, and clear and reasonable menu distinction. At the center of the SB150 is Sunland's high-performance optimized space vector ...

Senlan low-voltage inverter has four series of applications Senlan low-voltage inverter has four series of applications

1.SB200 fan pump special inverter, widely used in textile, printing and dyeing, washing, cable, packaging, machinery, ceramics, constant pressure water supply, constant temperature control or various OEM. 2.HG1000 high-performance light-load intelligent inverter ...

The reason for VFD trip protection - Senlan The reason for VFD trip protection - Senlan

In general, there is a problem with the maintenance trip of the VFD. If you look at the faulty code, you can see what kind of fault is causing it. 1. The selection talent of VFD may be too small; Generally, when selecting VFD, it should be about 20% larger than the rated power of the motor, so that when the motor reaches full load...

Hope Sunland inverter fault code Hope Sunland inverter fault code

Er.ocb (1) Overcurrent at the moment of starting: There is a short circuit inside the motor There is a short circuit in the motor wiring The starting voltage is too high Check the motor and wiring Check the motor wiring Seek service Check the torque boost settings ...

Senlan frequency conversion cabinet wiring steps Senlan frequency conversion cabinet wiring steps

The wiring of the inverter cabinet refers to the correct connection between the inverter and the motor, power supply and other equipment. The wiring requirements of the cabinet are carried out in accordance with the electrical principles and equipment specifications to ensure the normal operation and safety of the system. The following is the cabinet ...

At the physical level, the stable operation of the inverter is guaranteed-Senlan inverter At the physical level, the stable operation of the inverter is guaranteed-Senlan inverter

For the most popular electrical control equipment inverter (Variable-frequency Drive, VFD), as a precision electronic industrial control equipment, in order to run smoothly for a long time, we, as professional and technical personnel, need to be on the VFD device or before the operation.

The difference between soft starter and inverter - Sunland inverter The difference between soft starter and inverter - Sunland inverter

Soft starter is actually a motor control device with motor soft start, soft stop, light load energy saving and a variety of maintenance functions. First of all, it is a three-opposite parallel thyristor and its electronic control circuit connected in series between the power supply and the controlled motor. By manipulating the conduction of three opposite parallel thyristors ...

The method of selecting the appropriate peripheral equipment for the inverter - Senland The method of selecting the appropriate peripheral equipment for the inverter - Senland

When we have selected a suitable Variable-frequency Drive (VFD), we also need to consider whether we need to equip other peripheral equipment according to the actual situation of the site. The peripheral equipment selected by VFD mainly includes circuit breakers, reactors, contactors, braking resistors, etc. ...

Introduction to the wiring rules of Sunland inverter Introduction to the wiring rules of Sunland inverter

It is necessary to separate the signal line from the power line: when using analog signals for long-distance control of the inverter, in order to reduce the disturbance of the analog amount from the inverter and other equipment, please separate the signal line of the control inverter from the strong current circuit (main circuit and sequential control circuit). Inverter ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top