When the peripheral equipment and the inverter share the same power supply, the disturbance generated by the inverter is transmitted against the power line, which will cause other equipment in the same system to malfunction. The following methods can be adopted:
(1) The input end of the inverter is equipped with an EMI filter or a ferrite common-mode filter (magnetic ring).
(2) Other equipment is blocked by blocking the noise with a barrier transformer or power filter.
Motor line radiation Power line radiation Inverter radiation The equipment or signal line that measures weak signals such as appearances, radio devices, and sensors is installed in the same cabinet as the inverter, and the wiring is very close, and it is simply disturbed by the space to produce malfunction, and the following countermeasures need to be taken:
(1) Simply affected equipment and signal lines should be kept away from the inverter device as much as possible. The signal line should be shielded wire, the shield layer should be grounded, the signal line cable should be sleeved into the metal pipe, and should be as far away as possible from the inverter and the input and output lines of the inverter. If the signal cable has to cross the power cable, it must be perpendicular to the two.
(2) Separation device EMI filter or ferrite common-mode filter (magnetic ring) on the input and output side of the inverter.
(3) The motor cable should be placed in a barrier of a larger thickness, such as a pipe of a larger thickness (more than 2mm) or buried in a cement tank.
The power line is sleeved into a metal tube and shielded to the ground (the motor cable is a 4-core cable, one of which is grounded on the inverter side and the motor housing on the other side).
(1) Prevent the signal line and the power line from being routed in parallel or bundled with the power line.
(2) Keep the simply affected equipment or signal lines as far away as possible from the inverter and the input and output lines of the inverter.
(3) The signal line and power line are shielded wires, and the metal pipes are separated from each other, and the distance between the metal pipes is at least 20cm.
|
More on that
|
The cause of leakage of the inverter-controlled motor - Senlan
In some fields, the use of inverter to control the motor will present the problem of leakage, and the leakage voltage ranges from tens of volts to 200 volts.
According to the inverter control motor ...
|
|
Get to know the capacitor of the inverter - Sunland inverter
1. The capacitance is generally indicated by "C" plus a number in the circuit (e.g., C25 indicates the capacitance numbered 25).
A capacitor is a component composed of two metal films close to each other and separated by an insulating material in the center. The characteristic of the capacitor is first and foremost the communication through the DC block. The size of the capacitance is ...
|
|
Overload trip analysis of an inverter
The motor is able to rotate, but the operating current exceeds the rated value, which is called an overload. The fundamental reflection of overload is that although the current exceeds the rated value, the fluctuation of the excess is not large, and it generally does not constitute a large inrush current.
1. The main reason for overload
(1) Excessive mechanical load ...
|
|
Learn the way of inverter - Senlan inverter
The inverter is an essential accessory in industrial use, and its main function is to regulate the speed of the motor. It is widely used in various equipment such as production F-line and machine tools. Many engineering people have touches.
The functions of the inverter are many, the parameters are complex, and it is difficult to play without professionals. ...
|
|
How to expand the application range of inverter - Sunland inverter
In the electrical profession, the use and development of energy-saving frequency conversion is very good, which has promoted the electrical profession to reach the pinnacle of science and technology again. Frequency converter (VFD) has a very good development shape in China, but it still has to withstand various tests. As long as you give full play to your professional advantages, you can gain a firm foothold in this society. VFD ...
|
|
Common maintenance methods of inverter - Senlan inverter
1. Step-by-step decreasing method
The so-called gradual reduction method is to gradually reduce the scale of the problem through the analysis of the problem phenomenon and the identification of measurement parameters, and finally implement it to the specific circuit or component that causes the problem. In essence, it is a certainty, a negation, a negation, a negation, a final ...
|
|
Common problems in the use of inverter - Sunland inverter
1. Please explain the maintenance function of the inverter?
(1) After detecting the abnormal situation, the correction action will be carried out automatically, such as overcurrent loss rate prevention, regeneration overvoltage stall prevention.
(2) After detecting the abnormality, the PWM control signal of the power semiconductor device is closed, so that the motor can park automatically. As...
|
|
Damage and repair of internal electronic components of the inverter - Hope Sunland
1. Repair the damage of the inverter rectifier block
The damage of the inverter rectifier bridge is also one of the common faults of the inverter, the inverter rectifier block in the early production is mainly diode rectifier, and now some rectifier blocks choose the rectifier mode of thyristor (voltage regulation and frequency modulation inverter).
Middle...
|
|
Inverter phenomenon detection method and judgment - Senlan
1. The power-on trip or the main power terminal part of the inverter shows sparks.
Disconnect the power cord, check whether the input terminal of the inverter is short-circuited, and check whether the DC side terminals P and N of the central circuit of the inverter are short-circuited. Perhaps the cause is a damaged rectifier or a short circuit in the central circuit.
2 ...
|
|
Whether the front end of the inverter can be installed with a motor protector - Senlan
Frequency conversion speed regulation motor is generally selected 4-level motor, the fundamental frequency operation point is planned at 50Hz, the frequency 0-50Hz (speed 0-1480r/min) scale of the motor for constant torque work, the frequency of 50-100Hz (speed 1480-2800r/min) scale of the motor for constant power work, the whole speed regulation scale of (0 ...
|
|
Heat dissipation method of small-capacity inverter - Senlan
Natural heat dissipation methods are generally used for heat dissipation of small-capacity inverters, because their operating environment should be well ventilated and free of dust and floating objects. The dragging objects of this type of inverter are mostly household air conditioners, CNC machine tools, etc., and the power is small.
...
|
|
Sunland won the "well-known brand of China's domestic inverter" for the fifth time in a row
On April 15, 2011, the "Century Tour of China's Automation Industry (CAIE2011)" was held in Beijing, and Sunland inverter was once again re-elected as "China's well-known brand of domestic inverter". Dr. Chen Bin, President of Continental Hope Group and Chairman of Hope Sunland Technology Co., Ltd., personally ...
|
|
Energy-saving operation method of air compressor inverter - Senland
At present, the domestic air compressor market takes the goal of energy saving, environmental protection and cost reduction as the primary demand, and the new products developed are very popular. However, economically speaking, it cannot completely replace the conventional screw air compressor with large area and large capacity in use. Therefore, the use of inverter technology to ...
|
|
Hope the advantages of Sunland inverter soft start
It is hoped that Sunland inverter and soft start is a first-class, reliable and reliable motor control system, which can meet the needs of various applications. The advantages of Hope Sunland inverter and soft start are:
1. **Sex: I hope that Sunland inverter and ...
|
|
Hope for an application example of Sunland inverter
Industrial process control: It is expected that Sunland inverters are widely used in industrial process production control, such as conveyors, tugboats, air compressors, pumps, and fans and other equipment in various control systems.
Mechanical control: It is expected that Sunland inverters are widely used in mechanical control, such as ...
|
|
The output side of the inverter is equipped with a contactor - Sunland inverter
When the power supply and the inverter are replaced, for example, if the inverter has a problem, in order to make an emergency, let the motor be directly changed to be driven by the power frequency power supply; Perhaps the inverter is used for soft starting, and after the motor is accelerated to the power frequency speed, it is changed to be driven by the power frequency power supply.
...
|
|
I hope that Senlan will make a wonderful appearance at the 22nd (Shanghai) Industry Fair
From September 15th to 19th, the 22nd China International Industry Fair was held at the National Convention and Exhibition Center (Shanghai). As the first national industrial exhibition held under the normalization of epidemic prevention and control this year, the theme of this expo is "Intelligence, Interconnection: Enabling the New Development of Industries".
|
|
Rapid selection method of low-voltage inverter - Sunland inverter
First, according to the classification and selection of inverters
1. Inverters can be divided into general-purpose inverters and special inverters.
2. General-purpose inverters are mainly used in: general fan pumps (referring to inverters that only drag a single fan or pump) loads, mechanical loads, and loads requiring high overloads.
|
|
Inverter remote control wiring method - Senlan
1. Connect X (switching input) drive terminal to control the inverter start-stop/forward and reverse rotation;
2. Connect to the AI (analog input) terminal to control the frequency of the inverter (perhaps made into PID closed-loop control active conditioning frequency)
3. Other DO (switching output) is used for transmission ...
|
|
Asynchronous motor with inverter method - Senlan
Before the asynchronous motor is equipped with an inverter, let's take a look at the three major types of mechanical equipment loads:
1. Constant torque load: such as conveyor belt and mixer; When the inverter drags the load of constant torque nature, the torque at low speed should be large enough, and the overload should be large enough. If you need ...
|
|