The reason why the frequency of the inverter cannot be adjusted - Senlan inverter

Create Date: 2024-8-30 12:03:23|Source: Hope Sunland

If there is no damage to the hardware, the maximum torque output of the inverter is generally less than the load to increase the torque.

                                 The reason why the frequency of the inverter cannot be adjusted - Senlan inverter

The acceleration time is too short

Theoretically, the longer the acceleration time, the stronger the ability to increase the load, the setting acceleration time is too short, some inverters will display overcurrent or overload and overheating alarms, etc., but some will not be displayed, just stuck in a certain frequency segment.

The V/F ratio is too large

Some inverters are also called torque increase, this parameter is set too large, sometimes the minutes will not be able to start normally, and a proper reduction will solve the problem.

Vector manipulation parameters do not match

After running for a period of time, the motor parameters are overheated to form an offset, and the current will be too large, and the motor can not be started normally, and the frequency may also be stuck at a certain point.

The maximum frequency and maximum frequency are set too low

Generally, these two parameters are set to the maximum value, but some careless electricians who do not sweep away these two parameters have changed these two parameters, so it will also form a failure to increase the frequency.

Some special occasion parameters require pairing

In some cases, the minimum frequency can not be set too low, for example, in the constant pressure water supply system, after the minimum frequency is set to 0Hz, when the pump pressure is low, the inverter starts to speed up when the starting frequency of the inverter is exceeded, and the pressure cannot be increased, and the frequency of the inverter can not be increased to 50Hz, only about 38Hz. Only when the minimum frequency of the inverter is set to about 15-20HZ, the acceleration of the inverter can be satisfied, and the constant pressure of the water pump can be reached to a certain pressure position. Although the pressure meets the requirements of constant pressure, when no water is used, the inverter cannot be completely stopped, and the speed of the lowest frequency is maintained all the time.

This is due to: in the constant pressure water supply system, the minimum frequency of the inverter cannot be set to 0HZ, generally at least about 20HZ, which is determined by the flow rate and head of the pump.

The solution is to set the sleep frequency, when the pump does not use water at the frequency (for example, 28HZ) for a few minutes, the pump sleeps, and when the pressure drops to 0.2-0.4MP lower than the set pressure, the pump starts. Another way is to set up punctual water supply, punctual water supply in several time periods, generally constant pressure water supply controllers have the functions mentioned above.

Hardware issues

After the transformer (Hall) of the inverter presents a problem, it cannot measure the correct current normally, or it may produce a similar situation, and a measurement component on other motherboards is aging, which will also occur when repairing the inverter.

More on that
How to choose an inverter - Hope Sunland How to choose an inverter - Hope Sunland

The selection of the inverter should be considered according to the type of controlled object, speed regulation scale, static speed accuracy, starting torque, etc., so that it can be easy to use and economical together with meeting the process and production requirements. According to the different forms of devices, it can be divided into four types, which can be divided into four types according to the controlled motor power and field device ...

The inverter's requirements for the surrounding environment - Senlan The inverter's requirements for the surrounding environment - Senlan

1) Operating temperature: The inverter is a high-power electronic component, which is simply affected by the operating temperature, and the general temperature requirement is 0 - 55. However, in order to ensure the safety and reliability of the operation, it is necessary to consider freeing up space when using, and it is best to control it below 40. The inverter generally requires the device to operate ...

Inverter control motor speed method - Senlan Inverter control motor speed method - Senlan

1. Why can the rotation speed of the motor be changed freely? The unit of motor rotation speed: r/min the number of rotations per minute, can also be expressed as rpm. Example: 2-pole motor 50Hz3000 [r/min] 4-pole motor 50Hz1500[r/min] Conclusion: The rotation of the motor ...

Sunland inverters are designed for environmental requirements Sunland inverters are designed for environmental requirements

1. The ambient temperature ---- is generally "-10-+40°C"; Derating between 40 and 50°C, the additional output current must be reduced by 1% for every 1°C increase. If the ambient temperature is too high and the temperature changes greatly, the insulation of the inverter will be greatly reduced, which will affect the life of the inverter. ...

Whether the front end of the inverter can be installed with a motor protector - Senlan Whether the front end of the inverter can be installed with a motor protector - Senlan

Frequency conversion speed regulation motor is generally selected 4-level motor, the fundamental frequency operation point is planned at 50Hz, the frequency 0-50Hz (speed 0-1480r/min) scale of the motor for constant torque work, the frequency of 50-100Hz (speed 1480-2800r/min) scale of the motor for constant power work, the whole speed regulation scale of (0 ...

Senlan identifies the fault place of the inverter Senlan identifies the fault place of the inverter

How to distinguish where the inverter is wrong? Step 1: Static data checking 1. Check the inverter circuit The red watch rod is received to the P end, and the black watch rod is separated from U, V, and W, and there should be a resistance value of tens of ohms, and the resistance value base of each phase, the same, the opposite should be infinite.

Inverter control scheme for fan and water pump - Senlan inverter Inverter control scheme for fan and water pump - Senlan inverter

There are many control methods for inverters for fans and pumps, which can be selected according to specific conditions. Here are a few common scenarios. (1) Manual adjustment This is the simplest control method, that is, the operator instructs according to the instrument, ...

There is a problem with the inverter-controlled motor pressing the stop button There is a problem with the inverter-controlled motor pressing the stop button

What happens when the inverter-controlled motor presses the abort button, and the motor is not controlled to speed up? 1. If it is a newly installed inverter, it is generally necessary to consider the wiring problem, you can first change the parameters to switch to the panel control, the panel is given the frequency, and then see if the inverter operation will appear in this ...

Senlan SV1000 servo drive check before power-on Senlan SV1000 servo drive check before power-on

1) Oil circuit inspection: Open the safety valve to check whether there is any leakage in the oil circuit. 2) Line check: whether the R, S, T, PE on the input side of the driver, U, V, W, PE lines on the output side and the control line are corresponding. 3) Check whether the power supply voltage of the incoming terminal of the servo drive is normal ...

The difference between strong and weak inverter - Sunland inverter The difference between strong and weak inverter - Sunland inverter

The inverter includes a rectifier circuit and an inverter circuit, and the input communication electricity is converted into DC voltage through the rectifier circuit and flat-wave circuit, and then through the difference between strong and weak current, it is mainly reflected in the different uses. Strong electricity is used as a kind of power power, and weak electricity is used for information transmission. In detail ...

Common problems in the use of inverters - Hope Sunland Common problems in the use of inverters - Hope Sunland

1. Please clarify the maintenance function of the inverter? (1) After detecting the abnormal situation, take the initiative to correct the action, such as overcurrent loss speed prevention, regeneration overvoltage stall prevention. (2) Block the power semiconductors after detecting the abnormality...

Differential overhaul method of inverter - Senlan Differential overhaul method of inverter - Senlan

For the dual requirements of anti-interference and galvanic isolation, the pre-circuit of the output current detection or voltage detection of the inverter usually uses the "matching" circuit of the linear optocoupler device and the differential amplifier to complete the transmission mission of the detection signal. The circuit of the differential amplifier is based on the current detection circuit ...

Senlan inverter selection points Senlan inverter selection points

1. Select the inverter according to the load characteristics, such as the load is constant torque load, you can choose Siemens MM440 inverter, ABB ACS800 series inverter, etc.; If the load is a fan or pump load, you can choose Siemens MM430 inverter, ABB ACS510 series inverter, etc. 2、 ...

15 Inverter Definitions – Hope Sunland 15 Inverter Definitions – Hope Sunland

1. What is frequency conversion resolution? What's the point? In the case of digitally operated inverters, the output frequency is given in a given order, even if the frequency command is an analog signal. The smallest unit of this gradient is called the variable resolution. Change...

Energy-saving operation method of air compressor inverter - Senland Energy-saving operation method of air compressor inverter - Senland

At present, the domestic air compressor market takes the goal of energy saving, environmental protection and cost reduction as the primary demand, and the new products developed are very popular. However, economically speaking, it cannot completely replace the conventional screw air compressor with large area and large capacity in use. Therefore, the use of inverter technology to ...

Damage to the inverter power module of the inverter - Senland Damage to the inverter power module of the inverter - Senland

1. Discrimination The inverter power module mainly includes IGBT, IPM, etc., check whether the appearance has exploded, and whether there are ablation marks between the terminal and the connected printed board. Use a multimeter to check whether C-E, G-C, G-E have been passed, or use a multimeter to measure whether the resistance of P to U, V, W and N to U, V, W is inadequate.

Inverter maintenance method - hope sunland Inverter maintenance method - hope sunland

1. Look After taking over a faulty inverter, remove the inverter shell and clean it up, and carefully investigate the appearance, shape, and integrity of the relevant components on the circuit board with both eyes according to the type of inverter fault. This method is about charging resistors, filter electrolytic capacitors, IG ...

Precautions for inverter wiring - hope Senlan Precautions for inverter wiring - hope Senlan

1. The inverter itself has strong electromagnetic disturbance, which will disturb the operation of some equipment, so we can add a cable sleeve to the output cable of the inverter. 2. The control line in the inverter or control cabinet is spaced at least 100mm, and the power cable is at least 100mm. 3. In the purchase of inverter ...

Anti-interference measures in the application of Sunland inverter Anti-interference measures in the application of Sunland inverter

The main manifestations of the disturbance of the inverter in the application are: higher harmonics, noise and oscillation, load matching, heat generation and other problems. These disturbances are unavoidable, because the input part of the inverter is a rectifier circuit and the output part is an inverter circuit, both of which are made up of nonlinear components that play a switching effect.

Sunland SB200 37KW inverter does not show analysis Sunland SB200 37KW inverter does not show analysis

After inspection, the circuit board of the machine is composed of a fan switching power supply board, a control board with a switching power supply and a driving board, etc., the fan power supply and the control board working power supply are independent of each other, the fan power supply output is normal, and the control board working power supply has no output due to failure. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top