At the Hannover Messe 2022 at the Industrial Fair (30 May 2022 * 2 June), Pilz will be presenting complete automation solutions including security and industrial security that can be automated independently and flexibly. Visitors will be able to see the unique adaptive solution first-hand at the Pilz booth.
Pilz will be present at Booth D17 in Hall 9 to witness the "Automation Transformation" at Pilz
The highlight: Safe automation of the control system
Pilz's new generation of modular safety relays, myPNOZ, can be mass-produced according to individual requirements and can be customized to monitor up to 16 safety functions. This is the first time you have seen myPNOZ in use at trade fairs since its launch. Pilz will be demonstrating how to use myPNOZ Creator to build a needs-based security solution from a variety of options. Without programming knowledge, myPNOZ successfully combines digitalization and Industry 4.0.
Flexible, distributed automation with new remote I/O modules
Pilz's new I/O module, PDP67 PN, expands its portfolio for distributed applications. The PDP67 PN sensors and actuators are equipped with IP67 protection and a rugged die-cast zinc housing to provide reliable monitoring in extreme temperatures (-30°C*70°C). Thanks to its robust design, it has an IP67 degree of protection and can be mounted directly on the machine. Thanks to the universal connection, which can be configured as inputs and outputs, the user only needs to keep an inventory of the device type, which saves a lot of space.
Secure access management solutions
Pilz will demonstrate how the new improvements of the modular safety gate system can effectively ensure the safety of the safety gate. This allows the user to flexibly combine a wide range of components to meet the requirements: from safety gate sensors, handle modules and escape devices, to diagnostic systems and appropriate evaluation devices. Users benefit from flexible assembly options, fast installation and configuration, simple operation and diagnostics.
Safe automation of AGVS
In Pilz's interactive display mode, we can experience that AGVS is not only designed and automated safely, but also safely applied to intralogistics. * It is important to take into account all space and infrastructure conditions. From the development of the system concept in the design phase to the best automation solution, to commissioning and specific training, Pilz experts will advise and support you in the implementation of your safety application. As a result, it meets the requirements of ISO 3691-4 and ensures productivity in operation.
|
More on that
|
Pilz: The path of innovation that began with the "mouse connection".
The debut of "Mouse Wire" in the world of automation dates back to 2002 at the SPS trade fair in Nuremberg, where Pilz presented users for the first time with a configurable small safety controller: no need to know a "higher-level" programming language, thanks to the ease of operation, the graphical ...
|
|
Pilz I.A.M. protects data and employees
How do you grasp the issues of employee protection, responsibility protection, work efficiency, and data protection? How can you improve quality and at the same time prevent machines from being tampered with? How can data and employees be protected in equal measure?
Through I.A.M. (Identification and Access Management) "...
|
|
A new product from Pilz is coming soon: the FSoE master module for PNOZmulti 2
PNOZ m EF EtherCAT FSoE is a forthcoming safety bus communication module from Pilz that supports the FSoE (FailSafe over EtherCAT) protocol. As a new member of the PNOZ multi 2 family, the module can be used as an FSoE master with a maximum cycle time of 10 ms ...
|
|
Pierz: The safety protection of the press can be so neat!
1. Presses = inflexible?
In the past, presses were often labelled as "sluggish", "inflexible" and "high-risk". With the development of technology, safety solutions for presses are emerging one after another, and the safety of presses is greatly improved. In the event that security is ensured...
|
|
Pilz – how safety light curtains are safe to install
1. The installation of the safety grating must be able to effectively prevent bypassing the detection area of the safety grating and contacting the dangerous moving parts, that is to say, the detection area of the installation grating can not have a blind spot, if the top or bottom of the safety grating has a fixed guard, the guard should be able to ...
|
|
Peel Magnetic Relays – Difference Between Voltage Relays and Current Relays
1. The difference between the structure of current relay and voltage relay
The main thing is that the coils are different.
The coil of the current relay is connected in series with the load to reflect the load current, so its coil turns are small and the wire is thick, so that the voltage drop when passing through the current is very small, and it will not affect the load circuit.
|
|
Pilz was unveiled at the "Safety Standardization" theme exhibition of China Machinery Industry Safety and Health Association
The "Safety Standardization" theme exhibition organized by the China Machinery Industry Safety and Health Association and the National Machinery Safety Standardization Technical Committee was unveiled at the China Yiwu International Commodities (Standards) Expo held from November 24 to 27, 2022. Automation specialist Pilz was invited to participate in the exhibition to demonstrate ...
|
|
The main anti-shielding measures of Pilz safety switches
1. Physical location of the installation – "out of reach or out of sight"
Consider installing the component in a place that is out of the reach of personnel, or directly outside the interlock switch as a protective cover to prevent disassembly or movement, as shown in the figure, whether it is a mechanical interlock on the left, or a non-...
|
|
Requirements for safety circuits for Pilz safety relays
1. When the emergency stop is lifted, the machine cannot be suddenly restarted
2. In case of failure of the machine safety circuit, the power supply of the machine can be stopped
3. When the safety circuit fails, the machine can no longer be started
Confirm safe input such as safety switches, light curtains, etc.
|
|
Pilz: New system version PSS 4000 1.24
The automation system PSS 4000 offers new features in the new version 1.24. Here's what you need to know:
New data types FIXED and LFIXED
The data types FIXED (a fixed digit with 6 decimal places) and LFIXED (a fixed number with 11 decimal places) are now ...
|
|
Pilz launches the maintenance system "Key in Pocket"
The new maintenance system "key in pocket" from Pilz prevents the risk of unauthorised machine restarts and increases the safety of maintenance work. Digital maintenance assurance is based on the access authorization system PITreader, which ensures the safety of machinery and industrial information.
|
|
Peel magnetic relays – testing of relays
(1) Measure the resistance of the contact: use the resistance of the multimeter to measure the resistance of the normally closed contact and the moving point, and the resistance value should be 0; The resistance between the normally open contact and the moving point is infinite. From this, it is possible to distinguish which is a normally closed contact and which is normally open.
(2) Coil resistance: multimeter R...
|
|
Peel magnetic relay - fault judgment and treatment method of safety relay
1. Determine whether the safety relay itself is faulty:
1. Separate from the three circuits of short-circuit S10/S12, S11/S12, S21/S22.
2. Turn on the 24V power supply (A1 is positive, A2 is negative), and the Power light should be on at this moment;
3. Reset the S33/S34 terminals, and the K1 and K2 lamps ...
|
|
Peel magnetic relays – how thermal relays control contactors
The main function of a thermal relay is to protect the motor.
The new electronic thermal relay has protection against overload, overcurrent, blocked rotor and various phase faults, current unbalance, interphase short circuit, inter-turn short circuit or overvoltage, undervoltage and so on.
In the process of using thermal relays, we should ...
|
|
Peel magnetic relay – the difference between a safety relay and a normal relay
1. The shape is larger
The dimensions of safety relays are different from ordinary relays, and safety relays are larger.
2. Modules instead of components
A safety relay is a module, not an electronic component like a normal relay.
3. Color
Quiet...
|
|
Requirements for Pilz to fix safety switches
Safety doors are mainly used to prevent the operation of the machine under certain conditions (usually when the guard is not closed) in order to avoid the occurrence of danger as much as possible. If the safety gate switch itself is not installed in compliance, resulting in its interlocking function not being implemented correctly, "it is time to do nothing", obviously ...
|
|
Peel magnetic relays – Precautions for the selection of relay modules
1. Whether the control voltage of the relay module is consistent with the system voltage.
2. It is still possible to use high level and low level for the level control mode of the relay module.
3. Depending on the requirements, choose whether you need a fully isolated relay module.
4. Safety: Relay ...
|
|
Pilz: Visualisation solution based on PNOZmulti2
Visualization solution PASvisu with OPC UA interface
Pilz is expanding its web-based visualisation solution PASvisu: From the new version 1.3 onwards, the OPC UA interface can be connected to the small controller PNOZmulti and other control systems.
Use...
|
|
Pilz: Configurable safety control systems for the filling industry
With the progress of the industrial level and the improvement of people's safety awareness, more and more attention has been paid to the safe operation of equipment in the workshop. As a professional supplier of safe automation solutions, Pilz's safety products are used in a wide range of industries. Configurable safety control system PNOZmulti ...
|
|
Peel magnetic relay - the wiring method, function and application of time relay
Wiring method of time relay
1. Control wiring
You think of it as a DC relay. 3. 7 is used to connect to 12V control voltage; 2. 7 is used to connect to 24V control voltage. 7 of them are used as the negative electrode of direct current, which is connected to the neutral line when used. 2. Connect to a 220V live wire.
2 ...
|
|