Pilz: Visualisation solution based on PNOZmulti2

Create Date: 2024-8-30 12:03:23|Source: PILZ/PILZ

Visualization solution PASvisu with OPC UA interface

Pilz is expanding its web-based visualisation solution PASvisu: From the new version 1.3 onwards, the OPC UA interface can be connected to the small controller PNOZmulti and other control systems.

With the web-based visualisation software PASvisu, automation projects can be easily configured and are outstanding in terms of visualization. In this way, users have a comprehensive and comfortable overview of their devices, whether locally or via remote access. A wide variety of display pages make the visualization visually appealing. Openness and platform independence are further key features of the web-based visualization solution PASvisu. Thanks to the OPC UA-Server connection, it can be used with all controllers used on the plant, such as the configurable control system PNOZmulti. The controller and visualization software are connected, and all variables come from the controller.
Pilz: Visualisation solution based on PNOZmulti2
  With its visualisation solution PASvisu, there is a close relationship between control and visualisation systems from Pilz. The deeper the tool is integrated into the machine, the more information the system can obtain from the user. This will bring a range of benefits, from engineering implementation to operation and maintenance. Since there is no longer a need to manually enter and assign variables, the implementation of automation projects is much faster. In the next version 1.4 of the visualisation software PASvisu, users will have access to the full functionality of the software, including diagnostic options, by connecting directly to PNOZmulti.

More on that
Safety circuit requirements for Peel magnetic relays Safety circuit requirements for Peel magnetic relays

1. When the emergency stop is lifted, the machine cannot be suddenly restarted 2. In case of failure of the safety circuit of the machine, the power supply of the machine can be stopped 3. When the safety circuit fails, the machine can no longer be started Confirm the safety of the transmission such as safety switches, light curtains, etc.

Pilz was unveiled at the "Safety Standardization" theme exhibition of China Machinery Industry Safety and Health Association Pilz was unveiled at the "Safety Standardization" theme exhibition of China Machinery Industry Safety and Health Association

The "Safety Standardization" theme exhibition organized by the China Machinery Industry Safety and Health Association and the National Machinery Safety Standardization Technical Committee was unveiled at the China Yiwu International Commodities (Standards) Expo held from November 24 to 27, 2022. Automation specialist Pilz was invited to participate in the exhibition to demonstrate ...

Pilmagnetic switch – the role of a load switch Pilmagnetic switch – the role of a load switch

1. Breaking and closing. Because it has a certain arc extinguishing ability, it can be used to break and close the load current and the overload current of a certain multiple (usually 3-4 times) of the small stem; It can also be used to break and close a no-load transformer with a larger capacity than the disconnector allows, a longer no-load line ...

Pierre Servo Amplifier - Introduction to the parameters of the servo amplifier Pierre Servo Amplifier - Introduction to the parameters of the servo amplifier

Positional proportional gain 1. Set the proportional gain of the position ring adjuster; 2. The larger the setting value, the higher the gain, the greater the stiffness, and the smaller the position lag under the same frequency command pulse. However, too large a value may cause oscillation or overshoot; 3. Parameter value ...

Pilz – an example of safety radar in the food industry Pilz – an example of safety radar in the food industry

The safety radar system PSENradar is a safe area protection monitoring device based on FMCW radar technology launched by Pilz, which is different from traditional area protection monitoring sensors, PSENradar is not easily affected by the external environment and is suitable for safe area protection monitoring under harsh conditions. ...

Pilz: Become a certified expert in industrial security Pilz: Become a certified expert in industrial security

Industrial security has become an integral part of automation, but with new requirements and specifications, manufacturers, integrators, and operators are faced with the question of how their employees can meet the new challenges. In response, Pilz has launched a new safety training course that can help students learn ...

Peel magnetic relay - the application and current situation analysis of solid state relays Peel magnetic relay - the application and current situation analysis of solid state relays

Applications for Solid State Relays (1) The recommended value of the foreign SSR trigger signal (i.e., the current through the light-emitting tube) is 10mA DC, and the recommended value of the domestic SSR trigger signal is 12-25mA DC. (2) Multiple SSRs can use the same trigger signal, which is common in the control of three-phase AC loads.

The Pilz PSS 4000-R solution contributes to railway safety The Pilz PSS 4000-R solution contributes to railway safety

With the continuous development of the city, the operation technology and demand of rail transit continue to upgrade. Many vehicle manufacturers have set their sights on "automatic guided track systems". Under this standard, the vehicle system has a high degree of automation, and can even achieve full automation and unmanned driving. Eye...

Pilz: How can I prevent my device from starting up unexpectedly? Pilz: How can I prevent my device from starting up unexpectedly?

In the process of adjustment, cleaning, maintenance and repair of mechanical equipment, the unexpected start of equipment due to various reasons is one of the most typical accident causes. Many companies may also be struggling with how to effectively control unplanned start-ups during maintenance. In order to have ...

Pilz: Can safety gate switches be used in series? Pilz: Can safety gate switches be used in series?

Recently, the "core shortage problem" has been plaguing major industrial control brand manufacturers, from safety PLCs and inverters, to safety door locks, etc., generally because of the lack of chips, resulting in longer delivery times, and some even unable to deliver the goods at all. This has created a "difficult problem" for the friends in the electrical design department.

Pilz: Configurable safety relays with reliable delivery times Pilz: Configurable safety relays with reliable delivery times

Have you encountered any of the pain points of these safety relay applications? Since the invention of the first emergency stop safety relay by Pilz in 1987, after twenty or thirty years of development, the current safety relay market can be described as a hundred flowers blooming and a hundred schools of thought contending. Although, the currently selectable security relay ...

Pilz: A new version is here! This time it's more powerful Pilz: A new version is here! This time it's more powerful

Since its launch, Pilz's flagship product, the configurable and safe small controller PNOZmulti, has been impressed by users for its robustness, flexibility and ease of operation. PNOZmulti Configurator as a configuration tool for the safe small controller PNOZmulti ...

Pilz: Mechatronics methods for automation Pilz: Mechatronics methods for automation

Smart factories, Industry 4.0 and autonomous production – the mechanical engineering department is now looking forward to a bright future. The pace of innovation and ever-shortening development moments are playing an increasingly important role in the global race. To streamline the engineering process and add reusability to individual components, the regulations ...

Introduction to the appearance and terminal blocks of the Pilz safety relay PNOZ s5 Introduction to the appearance and terminal blocks of the Pilz safety relay PNOZ s5

PNOZ s5 belongs to the PNOZSigma family and is a safety relay with a time-delay function There are 8 terminal blocks on the top and bottom of the module, where: A1 and A2 are the terminal blocks of the module power supply; S11 and S12 are terminal blocks for a set of safety input channels; S21 and ...

Pilz conducts brake tests on freight trains Pilz conducts brake tests on freight trains

The technology and business of rail freight have remained the same for decades. Until now, in order to test the brakes of freight trains, the crew would walk around the entire train and hit each axle with a special hammer to check the proper operation of the braking system. Rail transport systems in Austria ...

Peel Magnetic Relay – Safety Relay Alarm Reset Peel Magnetic Relay – Safety Relay Alarm Reset

1. First of all, press the safety relay overload protection button directly by hand. 2. Secondly, make its contacts recover and be in a closed state. 3. Finally, you need to wait for 3 minutes to be able to proceed, through the adjustment screw, choose a slotted screw, and go deep into the bottom ...

The Pilz automation system PSS 4000 assists in railway braking tests The Pilz automation system PSS 4000 assists in railway braking tests

The technology and business of rail freight have remained the same for decades. Until now, in order to test the brakes of freight trains, the crew would walk around the entire train and hit each axle with a special hammer to check the proper operation of the braking system. Rail transport systems in Austria ...

Pierre magnetic switch – the function of the disconnector Pierre magnetic switch – the function of the disconnector

1. After opening, establish a reliable insulation gap to separate the equipment or line that needs to be overhauled from the power supply with an obvious disconnection point to ensure the safety of maintenance personnel and equipment. 2. According to the operation needs, change the line. 3. It can be used to divide and combine small currents in the line, ...

Introduction to the principle and application of Pilz ground proximity switches Introduction to the principle and application of Pilz ground proximity switches

The Pilz safety proximity switch also belongs to a position sensor with a switching output, its measuring head is usually a plate that constitutes a capacitor, and the other plate is the object itself, when the object moves towards the proximity switch, the dielectric constant of the object and the proximity switch changes, so that ...

Peel magnetic relay – the difference between a transistor and a relay output PLC Peel magnetic relay – the difference between a transistor and a relay output PLC

1. The overload capacity of the transistor is less than the overload capacity of the relay In general, in the case of a large inrush current (e.g., bulbs, inductive loads, etc.), the transistor overload capability is smaller, and more derating is required. 2. Under the condition of rated operation, the relay has the number of actions ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top