1. Physical location of the installation – "out of reach or out of sight"

Consider installing components in a place that cannot be reached by humans, or directly outside the interlock switch as a protective cover to prevent removal or movement, as shown in the figure, whether it is a mechanical interlock on the left or a non-contact interlock on the right, there is an opportunity to prevent shielding through the protective cover.

2. Installation physical location – "out of sight"

The interlock switch itself is mounted directly and discreetly, making it difficult to easily identify and remove.

3. Its own anti-shielding ability - "high coding level"

Is it possible to improve the anti-shielding capability through the safety gate switch components themselves?

The general mechanical deadbolt triggered switch, ordinary magnetic switch, hinge switch, are all low coding level, the operating head can have 1-9 different coding changes, and for high coding level, can achieve more than 1000 different coding changes, such as the PSENcode series of unique coding type switches, the control head only with the corresponding switch body induction identification.

If you need to deal with high-risk situations, you can choose a switch with a high code level. If it is still necessary to use switches with medium and low code levels in high-risk situations, additional protection measures are required.

Additional measures for the safety switch to prevent shielding

In addition to the previously mentioned measures to minimize the likelihood of discarded interlocks by selecting the switch mounting position and the switch coding level, the selection of non-removable fasteners or fastening measures is also one of the ways to consider. For example, cover or permanent fasteners (e.g. welding, adhesive, one-way screws, rivets) for protection.

Of course, the selection of the appropriate safety controller can also take on the task of preventing shielding in some cases, such as embedding some state tests in the logic, periodic tests, and stopping the dangerous movement of the starting machine once the monitoring finds an abnormality.
The main anti-shielding measures of Pilz safety switches

More on that
How to match the user's drive circuit with the input characteristics of the solid state relay How to match the user's drive circuit with the input characteristics of the solid state relay

Generally speaking, the input control voltage of the solid state relay is 3.2-32V. The control current is 5-30mA.Usually the SSR input circuit of 1-2 is not a constant current source circuit, and the input control voltage is 4-16V. The control current is 5-20mA, and the SSR input circuit with the larger rated current is connected to the constant current source ...

Peel magnetic relay - how to reset the safety relay alarm? Peel magnetic relay - how to reset the safety relay alarm?

1. Check the alarm cause of the relay, if there is a fault, reset the relay urgently, and replace the relay in time. 2. Check whether there is a protection alarm in the control system, if there is a protection alarm, the cause of the alarm will be eliminated, and the protection alarm system will be reset according to the corresponding steps. ...

Pilz offers a new service called "Machinery Safety Assessment" (MSE). Pilz offers a new service called "Machinery Safety Assessment" (MSE).

Automation specialist Pierz is now offering a new service, the Machinery Safety Assessment (MSE), to assess the machinery safety of existing machines. Data reports provide operators with a simple and quick overview of the safety and compliance status of their machines. Pilz provides a comprehensive risk assessment in its portfolio of services.

REPAIR OF PILZ SAFETY RELAYS REPAIR OF PILZ SAFETY RELAYS

AS MENTIONED EARLIER, PILZ SAFETY RELAYS ARE THE MAIN COMPONENTS FOR CONTROL CIRCUITS AND MONITORING AND PROTECTION SYSTEMS FOR ELECTRIC LOCOMOTIVES. When the locomotive is running, when the motor, electrical appliances or connection lines in the main circuit and auxiliary circuit fail, the fault can be replaced by the Pilz safety relay of the corresponding monitoring and protection system.

Pilz: Comprehensive advice for high efficiency Pilz: Comprehensive advice for high efficiency

Injection moulding specialist Waldorf Technik is headquartered in Hegau, Germany, and employs around 150 people. The company specializes in the development and construction of customized automation solutions for the disassembly and further processing of injection moulded parts, especially in the fields of medical technology and healthcare. The company is part of HAH...

Pilz has launched the new stand-alone base module PNOZ m C0 Pilz has launched the new stand-alone base module PNOZ m C0

In the safe configurable small controller series PNOZmulti 2 from Pilz, a new stand-alone base module PNOZ m C0 is now available. PNOZ m C0 has the structural characteristics of a safety relay, but it is just as powerful as a safety controller. It offers 8 ...

Pilz will be exhibiting at the Hannover Messe 2022 Pilz will be exhibiting at the Hannover Messe 2022

At the Hannover Messe 2022 at the Industrial Fair (30 May 2022 * 2 June), Pilz will be presenting complete automation solutions including security and industrial security that can be automated independently and flexibly. Visitors can enjoy a tour of the Peel ...

Introduction to the principle and application of Pilz ground proximity switches Introduction to the principle and application of Pilz ground proximity switches

The Pilz safety proximity switch also belongs to a position sensor with a switching output, its measuring head is usually a plate that constitutes a capacitor, and the other plate is the object itself, when the object moves towards the proximity switch, the dielectric constant of the object and the proximity switch changes, so that ...

Maintenance method of Germany PILZ Peel magnetic relay Maintenance method of Germany PILZ Peel magnetic relay

Maintenance method: 1. When selecting the solid-state relay used in the printed circuit board with small current specifications, because the lead terminal is made of high thermal conductivity material, the soldering should be carried out under the condition that the temperature is less than 250 °C and the time is less than 10S.

Pilz is actively involved in the research and practice of Industrie 4.0 Pilz is actively involved in the research and practice of Industrie 4.0

With the advancement of history, people have experienced the transformation from light industry to heavy industry, and then entered the era of automation brought about by innovation in the field of electronic computer technology and other scientific and technological fields.   The wisdom and potential of human beings are limitless, and today in the 21st century, we are experiencing new ...

SIX POINTS FOR SAFETY RELAY REPAIR IN PILZ SIX POINTS FOR SAFETY RELAY REPAIR IN PILZ

PILZ PILZ SAFETY RELAYS ARE THE MAIN COMPONENTS FOR CONTROL CIRCUITS AND MONITORING AND PROTECTION SYSTEMS FOR ELECTRIC LOCOMOTIVES. WHEN THE ELECTRIC LOCOMOTIVE IS RUNNING, WHEN THE MOTORS, ELECTRICAL APPLIANCES OR CONNECTION LINES IN THE MAIN CIRCUIT AND AUXILIARY CIRCUIT FAIL, THE FAULT CAN BE REPLACED BY THE PILZ SAFETY RELAY OF THE CORRESPONDING MONITORING AND PROTECTION SYSTEM.

Pilz: IEC 62443 – Industrial Information Security Standard (Part II) Pilz: IEC 62443 – Industrial Information Security Standard (Part II)

In the context of industrial automation, the term "safety" refers to the functional safety of equipment, which means that people and the environment are protected from damage from foreseeable coercion from machines, and the residual risk is more or less always present, but the residual risk cannot exceed the acceptable level. Through the use of security relay ...

Pilz: Three levels of security validation, tailored to the user Pilz: Three levels of security validation, tailored to the user

Pilz's safety validation services for plants and machines can now be customised to suit your needs, choosing between three different validation levels. This guarantees an efficient service tailored to individual requirements, allowing plants and machines to be designed in accordance with standards and with maximum safety. In the wind ...

Pilz - Presentation of the features of the safety relay PNOZ s60 Pilz - Presentation of the features of the safety relay PNOZ s60

In addition to the usual emergency stop monitoring, safety gate monitoring, light barrier monitoring and two-hand button monitoring, the safety relays of the PNOZsigma family are also functional, as well as safe speed monitoring, safe braking and braking monitoring. Voltage monitoring safety relays are also one of its features. PNO ...

Pilz safety light barriers provide safety for applications that require physical protection Pilz safety light barriers provide safety for applications that require physical protection

Pilz safety light curtains provide cost-effective safety for applications that require body protection. The safety light curtains have a wide operating range of up to 55 m and are ideally suited for the demarcation of external areas. Whether the user wants a single beam or a multi-beam encoder, in the PSENopt and PSENopt II series, there is a choice of 2 ...

Pilz – how safety light curtains are safe to install Pilz – how safety light curtains are safe to install

1. The installation of the safety grating must be able to effectively prevent bypassing the detection area of the safety grating and contacting the dangerous moving parts, that is to say, the detection area of the installation grating can not have a blind spot, if the top or bottom of the safety grating has a fixed guard, the guard should be able to ...

Peel magnetic relays – what are the ways in which the contacts of relays are used? Peel magnetic relays – what are the ways in which the contacts of relays are used?

There are 3 basic forms of relay contacts: (1) The two contacts are disconnected when the dynamic type (normally open, H-type) coil is not energized, and the two contacts are closed after the energizing is applied. It is represented by the pinyin prefix "H" of the word "合". (2) Dynamic breaking type (normally closed, D-type) coil is not energized when the two contacts ...

Pilz: Conventional mechanical risks of hydraulic presses and how to prevent them effectively Pilz: Conventional mechanical risks of hydraulic presses and how to prevent them effectively

With the rapid development of industrial technology, on-site equipment is also developing towards a high degree of integration and automation. But no matter how the technology develops, behind the dazzling technology, the basic common equipment is always a solid backing. The hydraulic press is one of the old industrial basic equipment, and it is almost ...

Pierre Servo Amplifiers – What are the basic requirements for servo amplifiers? Pierre Servo Amplifiers – What are the basic requirements for servo amplifiers?

Requirements for servo feed systems 1. Wide range of speed regulation 2. High positioning accuracy 3. There is sufficient transmission rigidity and high speed stability 4. Fast response, no overshoot In order to ensure productivity and processing quality, in addition to the requirement of high positioning accuracy ...

Pierz supports ACMI S.p.A.'s packaging process Pierz supports ACMI S.p.A.'s packaging process

ACMI S.p.A. is an Italy company specializing in high-tech bottling and packaging lines. Based in Fornovo Taro, in the province of Parma, Italy, the company initially produced palletizers and depalletizers for the food and beverage industry, and later specialized in all packaging processes. For...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top