Peel magnetic relays – how thermal relays control contactors

Create Date: 2024-8-30 12:03:23|Source: PILZ/PILZ

The main function of a thermal relay is to protect the motor.

The new electronic thermal relay has protection against overload, overcurrent, blocked rotor and various phase faults, current unbalance, interphase short circuit, inter-turn short circuit or overvoltage, undervoltage and so on.

We should pay attention to the following points in the process of using thermal relays.

First, when the motor starts for too long or the number of operations is too frequent, the thermal relay will malfunction or burn out the electrical appliance, so in this case, the thermal relay is generally not used for overload protection.

Second, the connecting wire at the outlet end of the thermal relay should be selected appropriately, if the wire is too thin, it will affect the relay may act in advance, if the wire is too thick, the thermal relay may lag in action.

Thirdly, when the thermal relay is installed together with other electrical appliances, it should be installed under other electrical appliances to avoid the influence of other electric heating on its working characteristics.

Fourth, the rated current of the thermal relay should be greater than the rated current of the motor.

Fifth, generally light load start, short time work, you can choose a two-phase structure of thermal relay, when the balance of the power supply voltage and the working environment is poor or the power difference of multiple motors is more significant, you can choose a three-phase structure of thermal relay.

Sixth, the normally closed point of the thermal relay is generally used to control the power supply of the contactor coil, and the normally open point of the thermal relay is used as the fault signal for power supply.

Seventh, generally adjust the setting current to be equal to the rated current of the motor, for the motor with poor overload capacity, the setting value of the thermal relay can be adjusted to 0.6 to 0.8 times the rated current of the motor, for the motor with a long starting time, dragging impact load or not allowed to stop, the setting current of the thermal relay should be adjusted to 1.1 to 1.15 times of the rated current of the motor.
Peel magnetic relays – how thermal relays control contactors

More on that
Common faults with Pilz safety relays Common faults with Pilz safety relays

The most common ones are the following: (1) Contact failure 1. The phenomenon that cannot be disconnected due to mechanical occlusion of the contact (the needle-like protrusion formed on the contact and the pit biting each other), fusion welding, or cold welding. 2. Due to the contact resistance becoming larger and unstable, the circuit cannot ...

Pilz: Conventional mechanical risks of hydraulic presses and how to prevent them effectively Pilz: Conventional mechanical risks of hydraulic presses and how to prevent them effectively

With the rapid development of industrial technology, on-site equipment is also developing towards a high degree of integration and automation. But no matter how the technology develops, behind the dazzling technology, the basic common equipment is always a solid backing. The hydraulic press is one of the old industrial basic equipment, and it is almost ...

Peel magnetic relays - what are the connection methods of relays? Peel magnetic relays - what are the connection methods of relays?

1. 3-pin relay wiring The common 3-pin relay is the car horn relay. No. 1 is the contact terminal, which connects the load; No. 2 is the common terminal between the contact and the coil, which is connected to the power supply; No. 3 is the coil terminal, which connects the button switch (such as the horn on the steering wheel).

Pilz was unveiled at the "Safety Standardization" theme exhibition of China Machinery Industry Safety and Health Association Pilz was unveiled at the "Safety Standardization" theme exhibition of China Machinery Industry Safety and Health Association

The "Safety Standardization" theme exhibition organized by the China Machinery Industry Safety and Health Association and the National Machinery Safety Standardization Technical Committee was unveiled at the China Yiwu International Commodities (Standards) Expo held from November 24 to 27, 2022. Automation specialist Pilz was invited to participate in the exhibition to demonstrate ...

Pilz is actively involved in the research and practice of Industrie 4.0 Pilz is actively involved in the research and practice of Industrie 4.0

With the advancement of history, people have experienced the transformation from light industry to heavy industry, and then entered the era of automation brought about by innovation in the field of electronic computer technology and other scientific and technological fields.   The wisdom and potential of human beings are limitless, and today in the 21st century, we are experiencing new ...

Pilz myPNOZ is even better suited to two-handed buttons Pilz myPNOZ is even better suited to two-handed buttons

The two-handed button is a commonly used safety start device, which is commonly used in punches, presses, cutting machines and other equipment; The purpose is to force the operator to leave the danger zone with his hands when driving the machine, so as not to come into contact with dangerous moving parts and cause safety accidents.   The "standard" of two-handed control says ...

Functions of Pilz Functions of Pilz

1. When the load exceeds the action current, the circuit will be automatically cut off; 2. After the circuit is automatically cut off, the panel indicator light is on, which is convenient for the judgment of the fault part; 3. After troubleshooting, press the red button at the bottom of the panel to restore the normal power supply; 4. For other reasons, the shell ...

Pilz: The best helper for safety control systems Pilz: The best helper for safety control systems

The safety control system generates a large amount of data at all times while ensuring the safety functions of its equipment. For example, when the E-STOP button is pressed, when someone opens a certain safety door, who switches the machine to service mode when, etc. This data is important for device managers ...

Pilz: Visualisation solution based on PNOZmulti2 Pilz: Visualisation solution based on PNOZmulti2

Visualization solution PASvisu with OPC UA interface Pilz is expanding its web-based visualisation solution PASvisu: From the new version 1.3 onwards, the OPC UA interface can be connected to the small controller PNOZmulti and other control systems. Use...

How do I remove the Pilz safety relay on the circuit board? How do I remove the Pilz safety relay on the circuit board?

1. The mount can be quickly replaced. 2. For low-value and easy-to-purchase multi-leg assemblies, destructive removal methods can be employed to prevent board stepping on. For this type of relay, use pliers to break it off and then use a set with a semicircular or triangular file.

Pilz: Configurable safety relays with reliable delivery times Pilz: Configurable safety relays with reliable delivery times

Have you encountered any of the pain points of these safety relay applications? Since the invention of the first emergency stop safety relay by Pilz in 1987, after twenty or thirty years of development, the current safety relay market can be described as a hundred flowers blooming and a hundred schools of thought contending. Although, the currently selectable security relay ...

Piermagnetic switches – an introduction to the functions of safety switches Piermagnetic switches – an introduction to the functions of safety switches

1. When the load exceeds the action current, the circuit will be automatically cut off; 2. After the circuit is automatically cut off, the panel indicator light is on, which is convenient for the judgment of the fault part; 3. After troubleshooting, press the red button at the bottom of the panel to restore the normal power supply; 4. For other reasons, the shell ...

Peel magnetic relays – features of relay modules Peel magnetic relays – features of relay modules

  1. The same module can be triggered by high or low level through different wiring, and the trigger current is not less than 1mA, and the output capacity of the IO port of some 51 single-chip microcomputers is weak, and the circuit of pulling up or increasing the driving capacity is required (the default is low level triggering); 2. Advantages of low-level drive, ...

Pilz I.A.M. protects data and employees Pilz I.A.M. protects data and employees

How do you grasp the issues of employee protection, responsibility protection, work efficiency, and data protection? How can you improve quality and at the same time prevent machines from being tampered with? How can data and employees be protected in equal measure? Through I.A.M. (Identification and Access Management) "...

Pilz: Cleared! The risks of the canning line are "gone" Pilz: Cleared! The risks of the canning line are "gone"

Today we share with you the case of ACMI S.p.A., an Italy company dedicated to the production of high-end filling and packaging lines, to see how they do the safety protection of canning lines.   Let's start with their process...... This mineral water filling ...

Peel magnetic relay - how to adjust the voltage of high and low voltage relays? Peel magnetic relay - how to adjust the voltage of high and low voltage relays?

1. Determine the voltage range that needs to be regulated: First of all, you must clarify the voltage range you need to regulate, as well as the specifications of the high and low voltage relays and the voltage range that can be adjusted. If there is no clear scope and specifications, you can check the relevant manuals of high and low voltage relays or consult the equipment manufacturer.

How Pilz safety relays are shorted to I10 points How Pilz safety relays are shorted to I10 points

Short-circuit method: when FD is displayed, it means that the safety loop is disconnected, at this time, the safety relay CC is disconnected, and the indicator light on the operation board is extinguished, first check whether the safety loop power supply fuse 1F1 (the 6th from the left in the lower row behind the control cabinet) is fused; Second, when the maintenance needs to be shorted, please ...

The Pilz Safety PC PSS 4000 system provides customers with a better service The Pilz Safety PC PSS 4000 system provides customers with a better service

When building a safety system, it is particularly important to arrange the components of the safety system reasonably, which determines whether the reliability of the entire system can be guaranteed. Nowadays, with the gradual popularization of safety concepts, people's requirements for safety automation are getting higher and higher, and the scenarios of safety PLC applications are also increasing. ...

Peel magnetic relays – what do you need to do when equipping your machine with a safety light curtain? Peel magnetic relays – what do you need to do when equipping your machine with a safety light curtain?

1. Choose the correct encoder model 2. Build the right safety loop 3. There is no blind spot in the installation of safety light curtains 4. The safety distance of the safety light curtain meets the requirements of EN ISO 13855 ...

Introduction to the principle and application of Pilz ground proximity switches Introduction to the principle and application of Pilz ground proximity switches

The Pilz safety proximity switch also belongs to a position sensor with a switching output, its measuring head is usually a plate that constitutes a capacitor, and the other plate is the object itself, when the object moves towards the proximity switch, the dielectric constant of the object and the proximity switch changes, so that ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top