Peel magnetic relay – the difference between a safety relay and a normal relay

Create Date: 2024-8-30 12:03:23|Source: PILZ/PILZ

1. The shape is larger

The dimensions of safety relays are different from ordinary relays, and safety relays are larger.

2. Modules instead of components

A safety relay is a module, not an electronic component like a normal relay.

3. Color

Safety relays are available in proprietary colors, usually yellow, or red, or red and yellow as the main colors (just as explosion-proof safety designs, danger sides, and intrinsically safe ends are usually marked in blue). Of course, these are just scratching the surface.

4. [Core] is safer

Due to the difference in design principles: ordinary relays cannot achieve high diagnostic coverage (DC) and can only be used in the lower safety level machinery industry such as Cat.B/1 and process control industry SIL1. Through the requirements of relays and the auxiliary design of logic circuits, Anji's diagnostic coverage rate is high, and some can even reach 99.9%. And in some occasions with high safety requirements, there are also regulations that certified safety relays must be used to meet safety requirements!

5. Forced guidance structure

A "safety relay" is not a "relay that has no faults", but rather a regular action when a fault occurs. Unlike conventional relays, safety relays have a forced-guide contact structure (or other protection method) that ensures safety in the event of contact welding.

Safety relay: The core component is the forced guide relay, and the difference between the safety relay and the ordinary relay can be seen from the perspective of the relay.

Ordinary relay: The contact is fused, which will cause the two contacts (NO/NC) to appear ON at the same time.

Forced guide relay: Under the action of the internal forced guide rod, even if the contacts are fused, the two contacts (NO/NC) will not be ON at the same time. The forced-guided structure is a simple and effective way to detect contact fusion failures.
Peel magnetic relay – the difference between a safety relay and a normal relay

More on that
Peel magnetic relays – Precautions for the selection of relay modules Peel magnetic relays – Precautions for the selection of relay modules

1. Whether the control voltage of the relay module is consistent with the system voltage. 2. It is still possible to use high level and low level for the level control mode of the relay module. 3. Depending on the requirements, choose whether you need a fully isolated relay module. 4. Safety: Relay ...

Pilz: Bake delicious wafers safely Pilz: Bake delicious wafers safely

Franz Haas, the founder of the Bühler Group, invented the first wafer machine as early as the end of the 40s of the 20th century. Today, its subsidiaries are spread all over the world. In the wafer area of the consumer food division in Leobendorf, 700 employees are engaged in development, design and production, as well as sales, service, maintenance ...

Pierre Servo Amplifier - Introduction to the parameters of the servo amplifier Pierre Servo Amplifier - Introduction to the parameters of the servo amplifier

Positional proportional gain 1. Set the proportional gain of the position ring adjuster; 2. The larger the setting value, the higher the gain, the greater the stiffness, and the smaller the position lag under the same frequency command pulse. However, too large a value may cause oscillation or overshoot; 3. Parameter value ...

Pilz – how safety light curtains are safe to install Pilz – how safety light curtains are safe to install

1. The installation of the safety grating must be able to effectively prevent bypassing the detection area of the safety grating and contacting the dangerous moving parts, that is to say, the detection area of the installation grating can not have a blind spot, if the top or bottom of the safety grating has a fixed guard, the guard should be able to ...

Top 5 reasons to choose myPNOZ from Pilz Top 5 reasons to choose myPNOZ from Pilz

Pilz's modular safety relay myPNOZ has received a lot of attention and acceptance since its introduction. It has been nominated for the Hermes Award, the Germany Innovation Award (GIA) and the Red Dot Design Award. This safety app, which can be customized and mass-produced according to user requirements, can be customized according to user requirements.

The working principle and characteristics of Pilz safety relays The working principle and characteristics of Pilz safety relays

Pilz safety relays generally consist of an iron core, a coil, an armature, a contact reed, etc. As long as a certain voltage is added to both ends of the coil, a certain current will flow through the coil, resulting in an electromagnetic effect. Under the action of electromagnetic attraction, the armature overcomes the pulling force of the return spring and sucks in the iron ...

Steps for using Pilz safety relays Steps for using Pilz safety relays

Pilz safety relays consist of several relays and circuits to compensate for each other's abnormal defects and achieve the full functionality of a relay with low misoperation or even correct relays. The lower the fault value and fault, the higher the safety factor. In order to prevent unavoidable misoperation or natural wear and tear of the machine, it should also be ...

Introduction and benefits of Pilmagnetic security locks Introduction and benefits of Pilmagnetic security locks

The use of safety locks If there are hazards in the equipment, such as moving levers, rotating mechanisms or even robots, in order to avoid damage to the operator, a safety gate system will be added to the protective cover (door). Safety door interlocking devices are widely used in the field of industrial safety. ...

ANALYSIS OF THE WORKING PRINCIPLE OF PILZ SAFETY RELAYS ANALYSIS OF THE WORKING PRINCIPLE OF PILZ SAFETY RELAYS

Germany Pilz automatic switching element with isolation function PILZ relay: PILZ relay is an automatic switching element with isolation function, widely used in remote control, telemetry, communication, automatic control, mechatronics and power electronic equipment, is one of the important control components. ...

How Pilz replaces the safety switch How Pilz replaces the safety switch

1. First, unscrew out the fixing screws of fixing the noodle frame and the water baffle plate according to the above steps; 2. Unscrew out the two screws that fix the safety switch, and pull out the two lead pins connecting the safety switch; 3. Replace the new safety switch and assemble it according to the original steps. Electrical safety switch ...

Peel magnetic relays – what are the ways in which the contacts of relays are used? Peel magnetic relays – what are the ways in which the contacts of relays are used?

There are 3 basic forms of relay contacts: (1) The two contacts are disconnected when the dynamic type (normally open, H-type) coil is not energized, and the two contacts are closed after the energizing is applied. It is represented by the pinyin prefix "H" of the word "合". (2) Dynamic breaking type (normally closed, D-type) coil is not energized when the two contacts ...

Pilz - Presentation of the features of the safety relay PNOZ s60 Pilz - Presentation of the features of the safety relay PNOZ s60

In addition to the usual emergency stop monitoring, safety gate monitoring, light barrier monitoring and two-hand button monitoring, the safety relays of the PNOZsigma family are also functional, as well as safe speed monitoring, safe braking and braking monitoring. Voltage monitoring safety relays are also one of its features. PNO ...

The Pilz PSS 4000-R solution contributes to railway safety The Pilz PSS 4000-R solution contributes to railway safety

With the continuous development of the city, the operation technology and demand of rail transit continue to upgrade. Many vehicle manufacturers have set their sights on "automatic guided track systems". Under this standard, the vehicle system has a high degree of automation, and can even achieve full automation and unmanned driving. Eye...

How Pilz safety relays work How Pilz safety relays work

PILZ SAFETY RELAYS GENERALLY CONSIST OF AN IRON CORE, COILS, ARMATURES, CONTACT REEDS, ETC. As long as a certain voltage is added to both ends of the coil, a certain current will flow through the coil, resulting in an electromagnetic effect, and the armature will overcome the tensile force of the return spring under the action of electromagnetic force attraction to ...

Peel magnetic relay - introduction to the characteristics of high and low voltage relays Peel magnetic relay - introduction to the characteristics of high and low voltage relays

1. High-precision detection: high and low voltage relays can detect high and low voltage signals with high precision, and realize accurate monitoring and control of electrical equipment. 2. Large capacitance switch: High and low voltage relays have good durability and stability when switching high capacitance loads. ...

Peel Magnetic Relays – How to Choose a Solid State Relay Peel Magnetic Relays – How to Choose a Solid State Relay

The naming of solid state relay models has not been unified, and the following conditions should be considered when selecting the manufacturer's manual. (1) Rated input voltage Refers to the maximum allowable effective voltage of a steady-state resistive load that can be withstood under a given condition. When used for inductive loads ...

An overview of Pilz safety switches, their advantages and application areas An overview of Pilz safety switches, their advantages and application areas

Optimal safety gate and position monitoring via safety switches Safety switch Safety switches can be used in a variety of applications: When the guards are opened, dangerous machine movements must be stopped and restarts must be prevented. These guards must be prevented from failing or being manipulated. ...

Pierre magnetic switch – the function of the disconnector Pierre magnetic switch – the function of the disconnector

1. After opening, establish a reliable insulation gap to separate the equipment or line that needs to be overhauled from the power supply with an obvious disconnection point to ensure the safety of maintenance personnel and equipment. 2. According to the operation needs, change the line. 3. It can be used to divide and combine small currents in the line, ...

Peel magnetic relay - the wiring method of PLC and relay Peel magnetic relay - the wiring method of PLC and relay

1. Y0 is connected to one end of the coil A1 of KA1; 2. The other end of KA1, A2, is connected to 24V; 3. Y1 is connected to A1 at one end of the coil of KA2; 4. The other end of KA2 A2 is connected to 24V; 5. COM terminated to 24V. ...

Peel magnetic relays – the characteristics and working principle of relays Peel magnetic relays – the characteristics and working principle of relays

When the input quantity (such as voltage, current, temperature, etc.) reaches the specified value, the electrical appliances that make the output circuit to be controlled on or off can be divided into two categories: electrical quantity (such as current, voltage, frequency, power, etc.) relays and non-electric (such as temperature, pressure, speed, etc.) relays.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top