|
Pilz I.A.M. protects data and employees
How do you grasp the issues of employee protection, responsibility protection, work efficiency, and data protection? How can you improve quality and at the same time prevent machines from being tampered with? How can data and employees be protected in equal measure?
Through I.A.M. (Identification and Access Management) "...
|
|
Pilz: Three levels of security validation, tailored to the user
Pilz's safety validation services for plants and machines can now be customised to suit your needs, choosing between three different validation levels. This guarantees an efficient service tailored to individual requirements, allowing plants and machines to be designed in accordance with standards and with maximum safety.
In the wind ...
|
|
Pilz was invited to attend the China Equipment Manufacturing Industry Youth Safety Expert Forum
Recently, the inaugural meeting of the Youth Safety Expert Working Committee of China Machinery Industry Safety and Health Association and the first China Equipment Manufacturing Youth Safety Expert Forum were held in Chengdu, Sichuan.
|
|
Pierre Switches – Requirements for securing safety switches
The fastener itself needs to be reliable and stable enough.
It can be removed with specialized tools, such as hexagon screws, star screws, etc. Phillips/slotted screws are not recommended, as in some cases these screws can be easily punched with nails or carry-on equipment.
|
|
Pilz Switches - Introduction to the use, characteristics and functions of high-voltage load switches
(1) Use
The high-voltage load switch is an electrical appliance with a function between the high-voltage circuit breaker and the high-voltage isolation switch, and the high-voltage load switch is often used in series with the high-voltage fuse; It is used to control power transformers. The high-voltage load switch has a simple arc extinguishing device, because it can turn on and off ...
|
|
Peel magnetic relays – the difference between safety relays and general relays
1) Larger shape: The safety relay is different from the ordinary relay, and the safety relay is larger.
2) Modules instead of components: A safety relay is a module, not an electronic component like a normal relay.
3) Red and yellow: The safety relay has ...
|
|
Pilz: Cleared! The risks of the canning line are "gone"
Today we share with you the case of ACMI S.p.A., an Italy company dedicated to the production of high-end filling and packaging lines, to see how they do the safety protection of canning lines.
Let's start with their process......
This mineral water filling ...
|
|
The main anti-shielding measures of Pilz safety switches
1. Physical location of the installation – "out of reach or out of sight"
Consider installing the component in a place that is out of the reach of personnel, or directly outside the interlock switch as a protective cover to prevent disassembly or movement, as shown in the figure, whether it is a mechanical interlock on the left, or a non-...
|
|
Pilz was rated as an advanced unit of the National Printing Machinery Standardization Annual Conference
On March 1, 2023, the National Printing Machinery Standardization Annual Conference and the First National Coating Machine Standardization Annual Conference were held in Yiwu, Zhejiang. The meeting was guided by the Standardization Administration of the People's Republic of China, the China Machinery Industry Federation, and the Yiwu Municipal People's Government.
|
|
Pilz myPNOZ is even better suited to two-handed buttons
The two-handed button is a commonly used safety start device, which is commonly used in punches, presses, cutting machines and other equipment; The purpose is to force the operator to leave the danger zone with his hands when driving the machine, so as not to come into contact with dangerous moving parts and cause safety accidents.
The "standard" of two-handed control says ...
|
|
Pilz: Conventional mechanical risks of hydraulic presses and how to prevent them effectively
With the rapid development of industrial technology, on-site equipment is also developing towards a high degree of integration and automation. But no matter how the technology develops, behind the dazzling technology, the basic common equipment is always a solid backing. The hydraulic press is one of the old industrial basic equipment, and it is almost ...
|
|
Pilz: Guard locking and safety interlocks in functional safety
In machinery safety, if it is an access door that prevents entry into the hazardous movement area, it is usually necessary to use a safety interlock switch to realize the "linkage" between the access door and the movement of the hazardous equipment, and when the access door is opened, the dangerous movement stops. In some cases, it is also necessary to prevent the access door from being hit.
|
|
The Pilz automation system PSS 4000 assists in railway braking tests
The technology and business of rail freight have remained the same for decades. Until now, in order to test the brakes of freight trains, the crew would walk around the entire train and hit each axle with a special hammer to check the proper operation of the braking system. Rail transport systems in Austria ...
|
|
Pilz: A new version is here! This time it's more powerful
Since its launch, Pilz's flagship product, the configurable and safe small controller PNOZmulti, has been impressed by users for its robustness, flexibility and ease of operation.
PNOZmulti Configurator as a configuration tool for the safe small controller PNOZmulti ...
|
|
Maintenance method of Germany PILZ Peel magnetic relay
Maintenance method:
1. When selecting the solid-state relay used in the printed circuit board with small current specifications, because the lead terminal is made of high thermal conductivity material, the soldering should be carried out under the condition that the temperature is less than 250 °C and the time is less than 10S.
|
|
Pilz Safety Burner Management System
An autonomously running burner management system has a complex structure and must comply with many international standards. Due to the high level of danger, strict safety regulations need to be applied to avoid the presence of unburned fuel in the combustion chamber. Pilz has a safe burner management system specifically tailored to these requirements.
...
|
|
Pilz safety switches – wiring methods for safety switches
1. The switch binding post is generally marked with L, L1, L2. When the L end enters the line, L1 and L2 have one end and L on, and after pressing the switch, the other end of L1 and L2 is connected to L.
2. Peel the thread with diagonal pliers first, and be careful not to leave too long the thread to avoid touching.
3. To the left ...
|
|
Pilmagnetic switch – the role of a load switch
1. Breaking and closing. Because it has a certain arc extinguishing ability, it can be used to break and close the load current and the overload current of a certain multiple (usually 3-4 times) of the small stem; It can also be used to break and close a no-load transformer with a larger capacity than the disconnector allows, a longer no-load line ...
|
|
Pilz: Become a certified expert in industrial security
Industrial security has become an integral part of automation, but with new requirements and specifications, manufacturers, integrators, and operators are faced with the question of how their employees can meet the new challenges. In response, Pilz has launched a new safety training course that can help students learn ...
|
|
What should I pay attention to when using Pilz safety switches in series?
When using Pilz safety gate switches in series, the following points need to be noted:
1. The installation position of the switch must meet the design requirements of the safety gate control system to ensure that no accidents will occur during operation.
2. When connecting the circuit, it should be in accordance with the ...
|