Wiring method and principle of PLC and inverter shielded wire - Reynolds

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

In order to avoid the interference of the control signal line between the PLC and the inverter by the space electromagnetic field, the shielding wire can be connected to the outer layer of these control signal lines to improve the anti-interference ability of the system. This kind of wiring must be noted, and only one point can be selected for the grounding point of the shield. Whether it's on the PLC side or on the inverter side. Generally, it is selected at the signal receiving end, that is, on the side of the inverter. In this way, the anti-disturbance ability of the system can be improved. If the shield wire is grounded at both ends, there will be current flowing through the shield wire, which will not only not improve the anti-interference ability of the system, but will aggravate the disturbance of the PLC by the outside world.

                                    Wiring method and principle of PLC and inverter shielded wire - Reynolds

The connection of PLC and inverter shielded wires adheres to the following guidelines:

1. The shield wire should be as close as possible to the low potential end, it can be understood that generally we think that the ground potential is "0", but in fact, if there are two grounding terminals, there will be a potential difference between the two grounding terminals at a certain time, and there will be a current between the two wires, which is also a kind of disturbance.

2. In actual use, if the place where the control cable passes through is more complex and requires multi-end grounding, we generally take the cutting of the shielding layer and then different local grounding. This method is also often used for the grounding of the communication cable shield of the control equipment of the factory.

More on that
The inverter protects the motor - Reynolds inverter The inverter protects the motor - Reynolds inverter

1. The output of the inverter for overvoltage maintenance has the function of voltage detection, and the inverter can actively adjust the output voltage, so that the motor does not bear the overvoltage, and the motor runs within the set voltage range. 2. Undervoltage maintenanceWhen the voltage of the motor is lower than 90% of the normal voltage (some are set to 85% ...

Reynolds frequency converters RNB1000 series E.ITE fault codes Reynolds frequency converters RNB1000 series E.ITE fault codes

Reynolds inverter problem code: E.ITE Reynolds inverter problem phenomenon/type: Problems with the current sensing circuit Possible causes of Reynolds inverter problems: 1. Poor contact of the control board connector 2. The auxiliary power supply is damaged 3. Hall ...

Lightning protection measures for Reynolds frequency converters Lightning protection measures for Reynolds frequency converters

The lightning protection measures of the inverter equipment are another important peripheral measure to ensure the safe operation of the inverter, especially in the area where lightning is active or in the lively season, this problem is particularly important. Today's inverter products are generally equipped with mines.

Reynolds inverter power selection Reynolds inverter power selection

The system power is equal to the product of the power of a general-purpose inverter and the power of the motor. As long as both work efficiently, the system power will be higher. From the perspective of power, when choosing VFD power, you should pay attention to the following points: VFD ...

The inverter has no short-circuit protection for the reason – Reynolds The inverter has no short-circuit protection for the reason – Reynolds

Short-circuit maintenance is a function of equipment connected between the power supply and the load, which can effectively disconnect the short-circuit point from the power supply when the load side is short-circuited. If an equipment has a short-circuit maintenance function, it must have a certain short-circuit breaking ability; And a device with the ability to break in a short circuit ...

Inverter acceleration and deceleration mode selection Inverter acceleration and deceleration mode selection

The selection of the acceleration form and deceleration form of the inverter is also called the selection of acceleration and deceleration curves. Generally, there are several forms of inverter, such as linear, S-shaped, semi-S-shaped, etc., and the characteristics and uses of each form are as follows. 1. Linear form The form makes the inverter ...

The role of frequency conversion technology in work equipment - Reynolds The role of frequency conversion technology in work equipment - Reynolds

Because inverters are widely used, there are many differences in the corresponding types and specifications. We are broadly divided into two categories: voltage and current. The current type of inverter products is characterized by the use of a large inductor as the energy storage link in the middle DC link, and the reactive power will be buffered by this inductor. ...

Method for measuring the quality of frequency converter modules – Reynolds Method for measuring the quality of frequency converter modules – Reynolds

1. Test rectifier circuit: To the P end and N end of the DC power supply inside the inverter, adjust the multimeter to the resistance X10 gear, the red watch rod is connected to P, and the black watch rod is separated from R, S, T, and there are tens of ohms of resistance in normal times, and it is basically balanced. Instead, connect the black watch rod to the P end, and the red watch stick will be ...

The heat dissipation method of Reynolds switching power supply The heat dissipation method of Reynolds switching power supply

1. Transfer heat pipes for heat dissipation. In many applications, the heat generated from the base steel plate of the power module is transferred through the heat transfer components to the distant heat pipe surface. In this way, the temperature of the base steel plate of the power module will be equal to the temperature of the heat pipe heat dissipation surface, the temperature of the heat transfer parts, and the temperature of the two contact ...

Key points for the selection of AC contactors - Reynolds Key points for the selection of AC contactors - Reynolds

1. Select varieties according to the above series according to the purpose and requirements of use Note that the main circuit load type is strictly differentiated, whether it is DC or communication. The communication contactor is different from the DC contactor, and is only suitable for DC-1 to DC-5 loads when used for DC loads.

Classification of Reynolds inverter types Classification of Reynolds inverter types

1. Classified according to the input voltage level According to the input voltage level, the inverter can be divided into low-voltage inverter and high-voltage inverter, and the low-voltage inverter is common in China with single-phase 220 V inverter, three-phase 220 V inverter, and i-phase 380 V inverter. High-voltage inverters are commonly used in 6 kV, 10 kV transformers.

Introducing the Reynolds JJR8000 series of intelligent soft starters Introducing the Reynolds JJR8000 series of intelligent soft starters

JJR8000 series of intelligent motor soft starter is the use of power electronics skills, microprocessor skills and modern control theory skills to produce today's international first-class starting equipment, the product can constrain the starting voltage of the asynchronous motor when starting, can be used in fans, water...

Applications of Reynolds frequency converters Applications of Reynolds frequency converters

A frequency converter is a power electronic device that can change the frequency of an AC power source to control the speed and output power of a motor. Inverters are widely used in industry, aviation, metallurgy, petroleum, chemical industry, electric power and other fields.

Abnormal handling of inverter series reactor - Reynolds Abnormal handling of inverter series reactor - Reynolds

Capacitor series reactors generally adopt epoxy glass fiber multi-encapsulated parallel structure, according to the characteristics of the device site, three-phase vertical stacking, three-phase horizontal "△" and three-phase horizontal "-" type distribution. The substation in the southern area ...

The working principle of the motor soft starter – Reynolds The working principle of the motor soft starter – Reynolds

Motor soft starter is the primary selection of power electronics skills and microprocessing skills and modern control theory and design and production of advanced level of new engine equipment, motor soft starter mainly has anti-interference function, high reliability, multiple protection functions and other characteristics, according to these characteristics of electric ...

DCS and PLC and other control cabinets are inspected before leaving the factory DCS and PLC and other control cabinets are inspected before leaving the factory

1. Test preparation: 1. It is necessary to remove all power switches before powering on the PLC control cabinet or IO cabinet. 2. It is necessary to completely cut off the connection between the PLC or DCS card and the outside. All front adapters are to be loosened and raised. 3. Check the power terminal wires and connectors.

The cause of bearing noise in different situations of frequency converters - Reynolds The cause of bearing noise in different situations of frequency converters - Reynolds

1. If the bearing is in good continuous rotation condition, it will emit a low whining or humming sound. Sharp hissing, squeaking and other irregular sounds often indicate that the bearing is in a bad continuous rotation condition. The sharp squeaky noise can be due to the formation of an inappropriately smooth ...

Wiring of Reynolds frequency converters Wiring of Reynolds frequency converters

1 Main circuit wiring (1) Reynolds inverter three-phase AC input terminal (R, S, T) The power input terminal is connected to the three-phase AC power supply through the circuit breaker of the circuit breaker for line protection, regardless of the connection phase sequence. It should be noted here that the three-phase AC power supply is not ...

Misunderstanding of inverter control loop wiring - Reynolds Misunderstanding of inverter control loop wiring - Reynolds

1. The wires of the inverter control circuit should be strictly distinguished from the main circuit cable (power line) and placed separately. This effectively prevents the inverter's control circuit from being disturbed by harmonics in the inverter's main circuit. 2. To separate the connection of the inverter from the terminals or contacts of other control circuits, ...

Application misunderstandings and drawbacks of inverter and countermeasures - Reynolds Application misunderstandings and drawbacks of inverter and countermeasures - Reynolds

Misunderstanding: connect electromagnetic switches and electromagnetic contactors in the output circuit of the inverter In actual use, some occasions require the use of contactors for frequency converter switching: such as when the frequency conversion is faulty, switch to the power frequency operation, or when the one-to-two method is adopted, a motor is faulty, and the variable frequency is used.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top