Reynolds JJR5000 series all-digital intelligent AC motor soft starter adopts power electronics technology, microprocessor technology and modern control theory technology, and is a new type of starting equipment at the international advanced level. This product can effectively limit the starting current of asynchronous motor start-up, and is widely used in heavy-duty equipment such as fans, pumps, conveyors, compressors, etc., and is an ideal alternative to step-down start-up equipment such as star/delta conversion and auto-coupling step-down magnetron step-down. Typical application introduction.
Water pump - use the soft stop function to alleviate the water hammer phenomenon when the pump is shut down, and save system maintenance costs.
Ball Mill – Utilizes voltage ramp start-up to reduce gear torque wear and reduce maintenance workload, i.e. save time and money.
Fan – reduces belt wear and mechanical shock, saving maintenance costs.
Compressor - use current limiting to achieve smooth start-up, reduce motor heat generation, and extend service life.
Crusher – Utilize clogging protection and quick protection to avoid mechanical failure or blockage that can cause the motor to overheat and burn out.
Conveyor Machinery – Smooth and gradual start-up with soft start to avoid product displacement and liquid spillage.
Features of the Reynolds JJR5000 series soft starters:
There are three starting modes: the voltage ramp start mode can obtain the maximum output torque, the constant current soft start mode can obtain the maximum starting current limit, and the heavy-load start mode can be applied to the heavy-load mode.
Parking method: Voltage slope is soft, free parking.
Programmable delayed start mode, programmable interlock control.
No phase sequence requires input power.
The start time and stop time can be modified digitally.
Overcurrent, three-phase current unbalanced, overheated, phase missing, current unbalanced, overheated, phase missing functions.
The dynamic fault memory function makes it easy to find the cause of the fault, and records up to five faults.
The maximum starting current and the maximum operating current can be found online.
The fieldbus fully dynamic control monitoring starter is easy to network. (Optional)
Chinese character display function: the LCD screen displays various working condition parameters, and there are text prompts for programming and fault conditions.
|
More on that
|
Progressive method of robustness of automatic control cabinets – Reynolds
1. Appropriate working environment
1. The ambient temperature is suitable
All manufacturers have certain rules for active temperature control cabinets. The PLC promises that the ambient temperature is usually about 0 to 55 ° C, so during the equipment process, this heating element is not placed in the PLC; The PLC should have adequate ventilation and ...
|
|
Difference Between Soft Starter and Inverter – Reynolds
Soft starters and frequency converters are two completely different products. The inverter is used in the local area where speed regulation is required, and its output not only changes the voltage but also changes the frequency at the same time; A soft starter is actually a voltage regulator, which is used when starting a motor, and the output only changes the voltage and does not change the frequency. Change...
|
|
The inverter protects the motor - Reynolds inverter
1. The output of the inverter for overvoltage maintenance has the function of voltage detection, and the inverter can actively adjust the output voltage, so that the motor does not bear the overvoltage, and the motor runs within the set voltage range.
2. Undervoltage maintenanceWhen the voltage of the motor is lower than 90% of the normal voltage (some are set to 85% ...
|
|
Features of the unit tandem inverter - Reynolds
(1) The multi-pronged PWM control method is selected, and the output voltage waveform is close to the sine wave.
(2) The rectifier circuit is multiplied, the number of pulses is as high as 36, the power factor is high, and the input harmonic is small.
(3) Modular design, compact structure ...
|
|
The reason why the inverter burns the power supply inlet end - Reynolds
1. It is necessary to consider the touch and current size of the incoming terminal, if the terminal standard is small, perhaps the conductive function of the terminal is poor, which will directly cause the current carrying capacity of the terminal to be small and heated.
2. The inlet at the end of the inlet line must be pressed well and the like, if it is not pressed, it may cause ...
|
|
Parameter setting of acceleration and deceleration time of Reynolds universal inverter
The acceleration time of the Reynolds inverter is the time required for the output frequency to rise from 0 to the high frequency, and the deceleration time is the time required to decrease from the high frequency to 0. Generally, the frequency converter uses the frequency setting signal to rise and fall to confirm the acceleration and deceleration time. The rise of the frequency setting must be limited when the motor accelerates.
|
|
Features of Reynolds high-voltage frequency converters
RNVH-A series high-voltage inverter adopts multi-unit series multi-level technology, which is attributed to high-high voltage source inverter, which can directly input 6KV/10KV and direct 6KV/10KV output. Taking the 6KV series as an example, each phase is connected in series by 5 power units, and each power unit is isolated by the input transformer.
|
|
The solution to the low or high output of the differential pressure transmitter – ifm
When the differential pressure flowmeter (V-cone flowmeter) is used in the field, it often encounters such and such problems, but the reason for it is investigated, as long as it is installed correctly, the primary problem is on the secondary surface differential pressure transmitter, and the following is the first to introduce these problems to us ...
|
|
Reynolds soft starter problem solving
1. The soft starter does not start and the fault-free code appears, perhaps because the control power supply is not connected, the solution is to check the power supply of the control power supply to see if the circuit connection is correct.
2. The motor starts when the motor announces a hum/no start signal, perhaps because of the thyristor/module ...
|
|
The soft starter output is out of phase fault
Soft Starter Repair Problem: F 04 (Input Phase Loss):
There are several factors that cause this problem, some of which are listed below:
(1) Check whether the wiring between the incoming power supply and the motor is loose;
(2) Whether the output is connected to the load, and whether the load is matched with the motor;
(3) ...
|
|
The main failure mode of mechanical parts – Reynolds
The top failure modes of mechanical parts:
Failure: The mechanical part cannot complete its normal function within the planning and booking period and under the regular conditions.
Ways in which mechanical parts fail: overall cracking, plastic deformation, corrosion, abrasion, gluing, and touch exhaustion
General ...
|
|
Inverter control method - Reynolds
The output voltage of low-voltage general frequency conversion is 380-650V, the output power is 0.75-400kW, and the operating frequency is 0-400Hz. Its control methods have gone through the following four generations. 1U/f=C Sinusoidal Pulse Width Modulation (SPWM) Manipulation MethodIts Characteristics ...
|
|
Overheating failure light on start-up analysis - Reynolds
(1) Frequent starting, resulting in excessive temperature, causing overheating maintenance of soft starter. (The number of starts of the soft starter should be controlled to no more than 6 times per hour, especially for heavy loads)
(2) During starting, ...
|
|
The Reynolds booth was presented at the Industrial Automation Exhibition Center in Parma, Italy
Shanghai Reynolds Technology Co., Ltd. is an enterprise specializing in the design and production of high and low voltage soft starters, high and low voltage variable frequency speed regulation, intelligent electrical, new energy electrical and high and low voltage power transmission and transformation equipment, which are widely used in electric power, metallurgy, petroleum and petrochemical, military, mining, chemical industry, ...
|
|
The relationship between Reynolds motion control and frequency converters
Motion control has obvious period characteristics, it is a variety of high-tech generalization, used to push industrial automation, office automation and home automation to a higher stage. Nowadays, motion control is mainly composed of variable frequency drive (VFD), electric motor, control ...
|
|
Frequency conversion cabinet external conduit wiring method - Reynolds
When it is required to wiring outside the frequency conversion cabinet, it is generally necessary to use the conduit for wiring, which requires suitable mechanical pressure and unsuitable mechanical damage, moisture-proof and corrosion-resistant. Conduits include the following two wiring methods:
1. Kim ...
|
|
Fault analysis of short circuit of inverter motor – Reynolds
According to the different degrees of short circuit, the inverter can display the short circuit of the SCF1 motor; SCF2 has an impedance short circuit; SCF3 is short-circuited to ground.
Causes of the problem: insulation problems with the cable from the motor or inverter to the motor; current transformer fault; ...
|
|
Control method of Reynolds inverter
The fulfillment device commonly used in the industrial field of Reynolds inverter has good speed regulation performance and simple and convenient operation method. Therefore, it is widely used in the automation system.
Typical wiring method for the main circuit of a Reynolds frequency converter
...
|
|
The frequency of the frequency converter is given in a given way
The first way to use the inverter is to change the output frequency to achieve the controllability of the motor speed, so do you know what steps to complete the output frequency controllability? One of the first and foremost key points is how to complete the change of the frequency signal supplied by the inverter equipment.
|
|
The cause of the damage of the inverter - Reynolds inverter
What are the causes of inverter damage?
First, the heat dissipation of the inverter is not good
In fact, we all know that too high a temperature can have a damaging effect on any device, just like the human brain, too high a temperature can also burn out the brain ...
|
|