Reynolds high-speed permanent magnet synchronous motor dedicated driver

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

The state proposes to "peak carbon emissions" by 2030 and complete "carbon neutrality" by 2060. Carbon neutrality is to try to reduce carbon dioxide emissions, and eventually achieve net zero emissions, that is, to make carbon dioxide emissions even offset.

However, due to economic development reasons, carbon dioxide emissions are bound to continue to increase for a considerable period of time before a steady decline, which is also a scientific rule, once carbon dioxide emissions reach a historical high, it may mark the inflection point from increase to decline, which is what we call "carbon peak".

In the context of carbon neutrality, Shanghai Reynolds has specially developed a special driver for high-speed permanent magnet synchronous motor on the platform of RNB2000 series inverter, and the RNB2000FH series of high-speed permanent magnet synchronous motor special driver is widely used in high-speed and high-end applications such as magnetic levitation and air suspension motors. For example, when used in the automatic scoring wheel cutting equipment, it can drive the high-speed spindle of air suspension, which can be used for the cutting of silicon, ceramics, glass, gallium arsenide, indium phosphide and other materials, as well as the cutting of various lead structures/substrate packages, and the cutting of 6-12 inch wafers. When driving air levitation, magnetic levitation high-speed compressor, high-speed blower, high-speed vacuum pump, it can be used in sewage treatment, papermaking, metallurgy, textile, cement, chemical, precision machining and other industries;

                                 Reynolds high-speed permanent magnet synchronous motor dedicated driver

In addition to the basic functions of inverter, the product also has the following professional characteristics:

· High efficiency, high speed, low noise, suitable for high-speed air levitation, magnetic levitation motor

· 16KHz carrier frequency, no oscillation of the motor, low noise

· The speed can reach 72000Rpm, and the motor efficiency can reach more than 98%.

· Energy-saving vector control algorithm, energy saving up to 20%-50%.

· It can be customized according to the user's operating environment
More on that
Rated current analysis of inverter leakage circuit breaker Rated current analysis of inverter leakage circuit breaker

The output of the inverter is controlled by PWM (pulse width modulation, similar to high-speed switching), so a high frequency leakage current will occur, if you want to install a general leakage disconnect switch on the primary side of the inverter, it is recommended to select a sensitivity current of more than 200mA for each inverter and the action time is 0.1 seconds ...

Structural characteristics of Reynolds RHY series inverter governor Structural characteristics of Reynolds RHY series inverter governor

1. Technology: (PC or PLC) is used to make the equipment complete the intelligent constant pressure variable supply water supply according to the requirements of water supply and fire protection; 2. High efficiency and energy saving: the system can set the pressure according to the demand, and the system actively adjusts the speed of the pump and the number of pumps according to the set pressure, so that the equipment can run in ...

How to deal with the inlet water of the inverter - Reynolds How to deal with the inlet water of the inverter - Reynolds

Inverters are widely used in all walks of life, in a variety of applications, inverters will inevitably encounter rainy and humid climate, resulting in internal wetness, or accidentally into the water, in fact, as long as it is found in time, it can still be rescued. If it is in the unpowered state ...

Centrifugal fan inverter selection method - Renol Centrifugal fan inverter selection method - Renol

1. See if it is energy-saving. When selecting equipment products, many business managers will take into account the energy-saving embodiment, which is due to the excellent energy-saving embodiment of the product, which can save a lot of money and resources.

Advantages of the inverter vector control system - Reynolds Advantages of the inverter vector control system - Reynolds

Dynamic "fast response" DC motors are rectified constrained and excessively high di/dt is not allowed. The asynchronous motor is only constrained by the capacity of the inverter, and the multiple of the forced current can be very high, so the speed echoes quickly, generally reaching the millisecond level, which has surpassed the DC motor in terms of speed. At low frequencies ...

The object of protection of frequency converters in overload protection - Reynolds The object of protection of frequency converters in overload protection - Reynolds

Inverters are mainly divided into two categories according to the frequency conversion method: communication/DC/communication and communication/communication inverters. Here we take the widely used general "communication/DC/communication" as an example to briefly talk about its structure and operating principle. As can be clearly seen from the above diagram, the communication/...

The item that needs to be maintained after the inverter is shut down – Reynolds The item that needs to be maintained after the inverter is shut down – Reynolds

1. Use a vacuum cleaner with a plastic nozzle to thoroughly clean the inside and outside of the inverter cabinet to ensure that there is no excessive dust around the equipment. 2. Check the ventilation and lighting of the frequency conversion room, and the ventilation equipment can operate normally. 3. Check the inverter ...

Inverter composition and various functions - Reynolds Inverter composition and various functions - Reynolds

Rectifier circuit: rectify 50HZ communication power into direct current. Frequency conversion circuit: The rectified direct current is inverted into a variable frequency communication current. Control part: control the frequency of communication electricity output by the inverter circuit. Maintenance circuit: maintenance and blockage of overcurrent and phase loss ...

Inverter dust handling – Reynolds inverters Inverter dust handling – Reynolds inverters

1. Plan a special inverter room: When the power of the inverter used is large or the number is large, a special inverter room can be planned. The doors, windows and cable holes in the room should be sealed to prevent dust from entering; It is necessary to plan air filtration equipment and circulation channels to adhere to the normal circulation of indoor air ...

Use the right power for the inverter – Reynolds Use the right power for the inverter – Reynolds

Low pressure issues The VFD reports a low voltage glitch when the drive's DC link voltage drops below 62% of the nominal level at the high setting (480 Vac) and 50% of the nominal value at the low setting (400 Vac). The +10% and -15% voltage tolerances in most manuals are the ones that claim to be ...

How to measure a frequency converter with a multimeter – Reynolds How to measure a frequency converter with a multimeter – Reynolds

How to use a multimeter to measure the quality of the inverter, it needs to be noted that for personal safety, it is necessary to ensure that the machine is powered off, and remove the inverter input power line R, S, T and output line U, V, W before operation! First of all, the multimeter is hit to the "secondary pipe" file, and then through the multimeter ...

Analysis and repair of inverter failure cases - Reynolds Analysis and repair of inverter failure cases - Reynolds

1. The inverter can not speed up the frequency increase when it starts with load The 1366S-BR 040 inverter carries a load of 37 kW fan motors. During the trial operation, it was found that the inverter could not speed up the frequency increase normally, and the HIM display was speeding up. The inverter only swings at 1-4 Hz, and the motor emits a buzzing ...

Small fan inverter choice - Reynolds Small fan inverter choice - Reynolds

Now many electrical appliances are advocating the use of small parts, because small parts will not occupy space, and small parts can be moved and overhauled at any time, and the inverter also has a small inverter, how to buy a small fan inverter? Power picking ...

The frequency of the frequency converter is given in a given way The frequency of the frequency converter is given in a given way

The first way to use the inverter is to change the output frequency to achieve the controllability of the motor speed, so do you know what steps to complete the output frequency controllability? One of the first and foremost key points is how to complete the change of the frequency signal supplied by the inverter equipment.

Reynolds frequency converters are remotely controlled for wiring Reynolds frequency converters are remotely controlled for wiring

1. Connect X (switching input) drive terminal to control the inverter start-stop/positive rotation; 2. Connect to the AI (analog input) terminal to control the frequency of the inverter (perhaps made into PID closed-loop control automatic adjustment frequency) ​ 3. ...

Method for measuring the quality of frequency converter modules – Reynolds Method for measuring the quality of frequency converter modules – Reynolds

1. Test rectifier circuit: To the P end and N end of the DC power supply inside the inverter, adjust the multimeter to the resistance X10 gear, the red watch rod is connected to P, and the black watch rod is separated from R, S, T, and there are tens of ohms of resistance in normal times, and it is basically balanced. Instead, connect the black watch rod to the P end, and the red watch stick will be ...

Precautions for the use of frequency converters - Reynolds Precautions for the use of frequency converters - Reynolds

In order to ensure the safe, efficient and reliable operation of the inverter, the following keys should be grasped when using the inverter: 1) It is necessary for the grounding terminal of the inverter to be firmly grounded, so as to effectively press the radio frequency disturbance and enhance the reliability of the system: the frequency conversion speed regulation system is best to use independent grounding, grounding resistance...

Reynolds soft starter fault code and fault handling Reynolds soft starter fault code and fault handling

Reynolds soft starter fault code Instantaneous stop -F 01 Instantaneous stop terminal 7 to terminal 10 open TOO LONG STARTING TIME -F 02 STARTING TIME IS TOO LOW AND THE STARTING TIME IS TOO LONG (GREATER THAN 60S) Overheating -F 03 Start too often, reduce the number of starts Input out of phase -F 04 ...

Safety precautions for low-voltage soft lift - Reynolds Safety precautions for low-voltage soft lift - Reynolds

Precautions for low-voltage soft starters For cooling purposes, the soft starter must be installed in a straight direction. In order to ensure excellent heat dissipation, there should be room for the soft starter device. Main circuit selection ...

Reynolds frequency converters RNB1000 series E.ITE fault codes Reynolds frequency converters RNB1000 series E.ITE fault codes

Reynolds inverter problem code: E.ITE Reynolds inverter problem phenomenon/type: Problems with the current sensing circuit Possible causes of Reynolds inverter problems: 1. Poor contact of the control board connector 2. The auxiliary power supply is damaged 3. Hall ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top