Reynolds JJR5000 series all-digital intelligent communication motor soft engine adopts power electronics skills, microprocessor skills and modern control theory skills, and is a new type of engine equipment at the current level. This product can limit the starting current of asynchronous motor starting, and is widely used in heavy-duty equipment such as electric fans, pumps, transportation, compressors, etc., and is an aspirational alternative to step-down start-up equipment such as star/delta conversion and auto-coupling step-down magnetron step-down. Introduction to typical use.
Water pump - use the soft shutdown function to alleviate the water hammer phenomenon when the pump is shut down, and save system protection costs.
Ball Mill - Uses voltage ramp to start, reduces the wear of gear torque, reduces the amount of protection work, that is, saves time and money.
Electric fan - reduce belt wear and mechanical impact, save protection costs.
Compressor - the use of current limiting, to achieve smooth start, reduce motor heating, and prolong the service life.
Crusher – Use blockage protection and quick protection to prevent mechanical glitches or blockages that cause the motor to overheat and burn out.
Handling Machinery – Smooth and gradual start-up process with soft start-up, preventing product displacement and liquid spillage.
Features of the Reynolds JJR5000 series of soft starters.
Three starting methods: the voltage ramp starting method can obtain the largest output torque, the constant current soft starting method can obtain the largest starting current limit, and the heavy-load starting method can be applied to the heavy-load starting method.
Parking method: Voltage slope is soft, free parking.
Programmable postponement start, programmable interlocking control.
No phase sequence requires input power.
The start time and parking time can be digitally modified.
Overcurrent, three-phase current unbalance, overheating, phase loss, current unbalance, overheating, phase loss function.
The function of dynamic fault recall is convenient to find the cause of the problem, and five more problems are recorded.
Able to find the largest starting current and the largest operating current online.
The fieldbus fully dynamic control monitoring starter is easy to network. (Optional)
Chinese character display function: the LCD screen displays various working condition parameters, and there are text prompts in the programming and fault state.
|
More on that
|
Parameter setting of acceleration and deceleration time of Reynolds universal inverter
The acceleration time of the Reynolds inverter is the time required for the output frequency to rise from 0 to the high frequency, and the deceleration time is the time required to drop from the high frequency to 0. Usually, the inverter uses the frequency setting signal to rise and fall to confirm the acceleration and deceleration time. When the motor accelerates, the rise of the frequency setting must be constrained ...
|
|
Reynolds-5G empowers the paper industry to improve quality and efficiency of the industrial IoT control system
From September 23rd to September 25th, 2020, the 2020 China International Paper Technology Exhibition was held in Hall D1 of Suzhou International Expo Center.
|
|
Inverter selection conditions and precautions - Reynolds
1. When selecting the inverter, select the inverter with the appropriate control method according to the load characteristics
In addition to the inverter manufacturing process, it is also important to choose which control method of the inverter. The control method of the inverter is mainly divided into two types: open-loop control and closed-loop control. In the meantime, the open-loop control method ...
|
|
The abnormal installation of the inverter in the power frequency motor leads to hazards
Installing a variable-frequency drive (VFD) on the power frequency motor can complete the precise control and speed regulation of the motor, and improve the power and accuracy of the progressive motor. However, if it is not properly used and used, the following damages may occur:
...
|
|
Inverter maintenance and undervoltage fault handling - Reynolds
In the repair of the inverter, we often hear about overpressure problems, but underpressure problems are also common problems encountered in the use of inverters. The reason is that the main circuit voltage is lower than the lower limit caused by the maintenance action or the damage of a rectifier bridge or the instantaneous power failure of the power grid, and the input is flat. Inverter after-sales ...
|
|
Features of electronic single-phase current transmitter – Reynolds
Single-phase current transmitter is a kind of electric power test substation developed for the power measurement of single-phase communication in motor experiments on the basis of motor experiment and testing technology research, in accordance with IEC and relevant national specifications for motor experiments. The use of advanced filtering technology, reasonable software algorithms, ...
|
|
The main circuit of the inverter is composed of Reynolds
When it comes to inverter repair, it's not enough to understand the above fundamental circuits, but also to understand the following primary circuits. The main circuit is mainly composed of rectifier circuit, current limiting circuit, filter circuit, braking circuit, inverter circuit and detection and sampling circuit.
...
|
|
AC servo motor with inverter control method - Reynolds
Because the inverter and servo are different in performance and function, and the use is not very different, it is not possible:
1) In the case of speed control and torque control, the general frequency converter is not very high, and there are also frequency converters that are used to react signals in the upper position to form a closed loop.
|
|
How long is the cable between the inverter and the motor allowed - Reynolds
The voltage waveform output by the inverter is only similar to a sine wave, but not a real sine wave, and its waveform contains a large number of harmonic components.
As we all know, the higher harmonics will increase the output current of the inverter, causing the motor winding to heat up.
|
|
Reynolds drives use the most energy-efficient method
As an electronic electric, the inverter itself also consumes electricity (about 3-5% of the additional power). A 1.5 hp air conditioner consumes 20-30W of electricity, which is equivalent to the length of a lamp. The inverter works under the power frequency and has the function of saving electricity, which is practical.
But the conditions are:
At the top of the list, great success ...
|
|
The cause of the damage of the inverter - Reynolds inverter
What are the causes of inverter damage?
First, the heat dissipation of the inverter is not good
In fact, we all know that too high a temperature can have a damaging effect on any device, just like the human brain, too high a temperature can also burn out the brain ...
|
|
The reason why the inverter burns the power supply inlet end - Reynolds
1. It is necessary to consider the touch and current size of the incoming terminal, if the terminal standard is small, perhaps the conductive function of the terminal is poor, which will directly cause the current carrying capacity of the terminal to be small and heated.
2. The inlet at the end of the inlet line must be pressed well and the like, if it is not pressed, it may cause ...
|
|
Selection of large fan inverter in the factory - Reynolds
First, select from the inverter "software".
The reason why the factory chooses the inverter to work together with the fan is that it is hoped that the automation and intelligent design of the inverter technology can improve the speed regulation mode of the fan, and reduce the wasted energy consumption, which not only improves the wind efficiency.
|
|
Common faults and solutions of vector inverter - Reynolds
The following faults may be encountered during the use of the inverter, please refer to the following methods for simple fault analysis:
1. No manifestation at power-on:
1) Use a multimeter to check whether the input power supply of the inverter is consistent with the rated voltage of the inverter, and check the cleaning problem.
2) ...
|
|
The solution to the low or high output of the differential pressure transmitter – ifm
When the differential pressure flowmeter (V-cone flowmeter) is used in the field, it often encounters such and such problems, but the reason for it is investigated, as long as it is installed correctly, the primary problem is on the secondary surface differential pressure transmitter, and the following is the first to introduce these problems to us ...
|
|
Problems between the inverter and the motor – Reynolds
1. The power and temperature rise of the motor
Regardless of the method of the inverter, different degrees of harmonic voltage and current occur during operation, so that the motor runs under non-sinusoidal voltage and current. Rejection of material introduction, taking the sine wave PWM type inverter that is now widely used as an example, ...
|
|
The breaking capacity of the industrial control appliance switch
Assuming Icu=60KA, then when a faulty current of 60KA is generated in the line, the circuit breaker can safely cut off the circuit without abnormal conditions such as contact welding and blasting. Pay attention to the extreme breaking ...
|
|
Safety standards for AC drives – Reynolds
International electrical safety standards: The requirements are in line with international electrical safety standards, such as CE standards in Europe and UL specifications in United States. These specifications specify the requirements for electrical safety functions, mechanical safety functions, EMC functions, etc.
...
|
|
Frequency characteristics of Reynolds frequency converters
a. Output frequency scale. The output frequency scale that can be controlled by the general inverter, the lowest starting frequency is generally 0.1Hz, and the highest frequency is different according to the functional indicators of the inverter, generally 400Hz, and some models are 650Hz. No matter how high the output frequency is, it depends on the scale of the high-frequency inverter.
...
|
|
Reynolds inverter power selection
The system power is equal to the product of the power of a general-purpose inverter and the power of the motor. As long as both work efficiently, the system power will be higher. From the perspective of power, when choosing VFD power, you should pay attention to the following points:
VFD ...
|
|