Introduction to soft starters and their relationship with frequency converters - Reynolds

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

When the high-power motor starts, the current is large, which will cause the grid voltage to be seriously shaken, in order to deal with this problem, the general requirements for speed regulation are not high, and the soft engine can be used to reduce the voltage and start. However, the drop in the starting current when the step-down is started will also cause the starting torque to drop significantly, so it is not suitable for starting with rated load, and it is generally suitable for no-load or light-load starting.

                               Introduction to soft starters and their relationship with frequency converters - Reynolds

When the motor needs to be started with load or has high requirements for speed regulation, the inverter is generally selected to start, which can reduce the starting current under the premise of ensuring a larger starting torque.

In addition, the step-down and constant voltage frequency ratio (constant air-gap magnetic flux) can be speed regulation, but the step-down speed regulation will make the mechanical characteristics of the motor softer, and the speed regulation scale is small. The speed regulation scale of constant voltage frequency ratio speed regulation is large, and the mechanical characteristics of the motor are hard.

The constant voltage frequency ratio speed regulation has so many excellent special effects, why not use it on a large scale, the answer is that the cost of the soft engine is very low, the AC power voltage regulation circuit can be realized, and the high-power inverter is expensive.
More on that
The reason for the large fluctuation of harmonic parameters in the harmonic test of the output harmonic test of the inverter The reason for the large fluctuation of harmonic parameters in the harmonic test of the output harmonic test of the inverter

In order to measure stable harmonics, it is necessary to meet the following two conditions: At the top of the list, the signal is a stable periodic signal. Second, it is necessary to perform harmonic analysis according to the integer multiple of the period of the stable periodic signal. ...

The difference between the voltage type and the current type of inverter - Reynolds The difference between the voltage type and the current type of inverter - Reynolds

Energy storage elements are different, the voltage type energy storage element is a capacitor, and the current type is an inductor. In fact, the general inverter uses power electronic circuits, which is a process of communication to DC - DC energy storage - DC to communication. It is also often said that the rectifier link --〉 energy storage link --〉 inverter ring ...

Inverter maintenance and undervoltage fault handling - Reynolds Inverter maintenance and undervoltage fault handling - Reynolds

In the repair of the inverter, we often hear about overpressure problems, but underpressure problems are also common problems encountered in the use of inverters. The reason is that the main circuit voltage is lower than the lower limit caused by the maintenance action or the damage of a rectifier bridge or the instantaneous power failure of the power grid, and the input is flat. Inverter after-sales ...

Introducing the Reynolds JJR5000 series of soft starters Introducing the Reynolds JJR5000 series of soft starters

Reynolds JJR5000 series all-digital intelligent AC motor soft starter adopts power electronics technology, microprocessor technology and modern control theory technology, which is a new type of starting equipment at the current level. This product can limit the starting current of the asynchronous motor when it starts, and is widely used in fans, ...

The inverter protects the motor - Reynolds inverter The inverter protects the motor - Reynolds inverter

1. The output of the inverter for overvoltage maintenance has the function of voltage detection, and the inverter can actively adjust the output voltage, so that the motor does not bear the overvoltage, and the motor runs within the set voltage range. 2. Undervoltage maintenanceWhen the voltage of the motor is lower than 90% of the normal voltage (some are set to 85% ...

Features of Reynolds high-voltage frequency converters Features of Reynolds high-voltage frequency converters

RNVH-A series high-voltage inverter adopts multi-unit series multi-level technology, which is attributed to high-high voltage source inverter, which can directly input 6KV/10KV and direct 6KV/10KV output. Taking the 6KV series as an example, each phase is connected in series by 5 power units, and each power unit is isolated by the input transformer.

There will be problems with the inverter left for a long time - Reynolds There will be problems with the inverter left for a long time - Reynolds

Most inverter brand products can rely on the heat generation of internal electrical components to remove moisture during normal use. If you don't have to do it for a long time, it's easy to get wet. The chip pins, penetrating resistors, capacitors, and inductor pins of the DIP package will be severely rusted or desoldered, resulting in on-resistance ...

Fault signal of the frequency converter - Reynolds frequency converter Fault signal of the frequency converter - Reynolds frequency converter

There are three types of fault signals for the inverter: (1) Excessive mechanical load: The primary feature of excessive load is that the motor heats up, and the operating current can be read from the display screen to find. The primary reason is that the load of the inverter is too large, and the acceleration and deceleration time and operation cycle time are too short; V/F ...

The soft starter output is out of phase fault The soft starter output is out of phase fault

Soft Starter Repair Problem: F 04 (Input Phase Loss): There are several factors that cause this problem, some of which are listed below: (1) Check whether the wiring between the incoming power supply and the motor is loose; (2) Whether the output is connected to the load, and whether the load is matched with the motor; (3) ...

The abnormal installation of the inverter in the power frequency motor leads to hazards The abnormal installation of the inverter in the power frequency motor leads to hazards

Installing a variable-frequency drive (VFD) on the power frequency motor can complete the precise control and speed regulation of the motor, and improve the power and accuracy of the progressive motor. However, if it is not properly used and used, the following damages may occur: ...

Protection function of the Reynolds soft starter Protection function of the Reynolds soft starter

1. Overload protection function: The soft starter introduces a current control loop, so that the change of motor current can be tracked and detected at any time. By increasing the setting of overload current and the anti-time control mode, the overload protection function is realized, so that when the motor is overloaded, the thyristor is turned off and an alarm signal is issued. ...

Advantages of the inverter vector control system - Reynolds Advantages of the inverter vector control system - Reynolds

Dynamic "fast response" DC motors are rectified constrained and excessively high di/dt is not allowed. The asynchronous motor is only constrained by the capacity of the inverter, and the multiple of the forced current can be very high, so the speed echoes quickly, generally reaching the millisecond level, which has surpassed the DC motor in terms of speed. At low frequencies ...

Soft-start starting method – Reynolds Soft-start starting method – Reynolds

1) Ramp boost soft start. This starting method is simple, does not have current closed-loop control, and only adjusts the conduction angle of the thyristor to make it add a certain function with time. The disadvantage is that because there is no current limit, in the process of motor starting, sometimes a large impulse current is generated.

Motor soft start mode – Reynolds frequency inverter Motor soft start mode – Reynolds frequency inverter

Starting performance is a very important performance parameter of motor products. The large starting current of the motor is an unpreventable problem in the process of direct starting. The high current during the engine process has a great impact on both the power grid and the motor itself. Therefore, according to different working conditions and different series of motors, ...

Inverter installation and heat dissipation treatment - Reynolds Inverter installation and heat dissipation treatment - Reynolds

The inverter has power loss during operation and converts it into heat energy, which increases its own temperature. Roughly speaking, the power loss of every 1kVA inverter capacity is about 40W-50W. Therefore, when installing the inverter, it is necessary to consider the heat dissipation of the inverter, and how to run the inverter.

Structural characteristics of Reynolds RHY series inverter governor Structural characteristics of Reynolds RHY series inverter governor

1. Technology: (PC or PLC) is used to make the equipment complete the intelligent constant pressure variable supply water supply according to the requirements of water supply and fire protection; 2. High efficiency and energy saving: the system can set the pressure according to the demand, and the system actively adjusts the speed of the pump and the number of pumps according to the set pressure, so that the equipment can run in ...

Reynolds drives RNB1000 series fault code resolution Reynolds drives RNB1000 series fault code resolution

Reynolds inverter fault codes: E.bC Reynolds inverter fault phenomenon/type: Brake unit failure   ​   Reynolds inverter failure may be caused: 1. Brake line failure or brake ...

The inverter uses a power-saving method – Reynolds The inverter uses a power-saving method – Reynolds

As an electronic electric, the inverter itself also consumes electricity (about 3-5% of the rated power). A 1.5 hp air conditioner consumes 20-30W of electricity, which is equivalent to the length of a lamp. The inverter works under the power frequency and has the function of saving electricity, which is practical. However, the conditions are: First, high power and ...

Wiring method and principle of PLC and inverter shielded wire - Reynolds Wiring method and principle of PLC and inverter shielded wire - Reynolds

In order to avoid the interference of the control signal line between the PLC and the inverter by the space electromagnetic field, the shielding wire can be connected to the outer layer of these control signal lines to improve the anti-interference ability of the system. This kind of wiring must be noted, and only one point can be selected for the grounding point of the shield. Whether it's on the PLC side, or ...

The way to set the parameters of the inverter - Reynolds The way to set the parameters of the inverter - Reynolds

There are many setting parameters of the inverter, and each parameter has a certain range of choice, and the inverter can not work normally due to the improper setting of a single parameter in use, therefore, the relevant parameters must be set correctly. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top