Delta's active front-end inverter partner
The ubiquity of AC drives brings significant energy savings to industrial applications. However, the high-frequency switching signal generated by the inverter is easy to form electromagnetic disturbance, which affects the power quality. It is especially significant in occupations with large loads such as lifting and elevators.
At this time, the inverter ...
|
|
The reason for the shaking of the inverter for the motor - Delta
When using the motor dragged by the inverter, sometimes the motor flutters and the over-fire flutter may burn out the motor and cause immeasurable losses. So what is the reason for this phenomenon?
1. The motor is damaged ...
|
|
How to choose Delta's power supply
1. First of all, calculate the maximum power consumption of the computer
The power consumption of the computer is different in different operating states, such as 95W on startup, 35W on standby, and up to 480W when the game is fully loaded.
The power consumption of the power supply is based on the computer ...
|
|
Delta's inverter process setting
1. Restore the inverter to factory settings, press the "ENTER" button to enter the parameter setting interface, and press it continuously until it is 00-00 and then stop. Press the number up button to change to 00-02. Press the "ENTER" key again, the panel value will show 0, press the number up key to change it to 9. Press the "ENTER" key, break ...
|
|
Introduction to the internal components of the inverter - Delta inverter
Rectifier circuits
It consists of six rectifier diodes from VD1 to VD6 to form an uncontrollable full-wave rectifier bridge. Regarding the rated power supply of 380V, the reverse withstand voltage value of the diode should be 1200V, and the forward current of the diode is 1.414-2 times of the rated current of the motor.
...
|
|
Precautions for storage of Delta inverter VFD-VE
It must be placed in a ventilated, dust-free, dry place.
The ambient temperature of the storage location must be in the range of -10°C to +40°C
The relative humidity of the storage location must be in the range of 0% to 90% and be free of dew.
...
|
|
Delta unveiled the ASDA-A2 series of AC servo motors and drives
New Delhi, September 2, 2010 – Delta Group, the world's largest supplier of switching power supplies and brushless DC fans, is committed to innovation, energy efficiency and environmental protection, and has launched a new and advanced high-performance ASDA-A2 series of servo motors and servo drives for motion control and networking in India.
|
|
Installation steps of the reducer - Delta
Correct installation, operation and maintenance of the reducer is an important part of ensuring the normal operation of mechanical equipment. Therefore, when you install a planetary reducer, it is necessary to carefully assemble and operate it in strict accordance with the following matters related to the operation of the device.
...
|
|
The impact of inverter cable design on the life of motor cables
Reflected waves that affect the impedance mismatch between the cable and the motor are pervasive in all AC VFD applications. The severity of the problem depends on the length of the cable, the rise time of the PWM (Pulse Width Modulation) carrier, the voltage of the VFD, and the magnitude of the impedance difference between the motor and the cable.
...
|
|
A brief introduction to Delta's inverters and their models
Delta's VFD drives have now established a wide range of brand awareness in the industrial automation market. Each series of products is designed for different operation needs such as torque, loss, overload, overspeed work, etc., and is adjusted according to different industrial machinery attributes; It can provide customers with a variety of choices, and a wide range of ...
|
|
Installation requirements for inverter energy consumption braking - Delta inverter
(1) The wiring interval between the braking unit and the inverter, as well as between the braking unit and the braking resistor, should be as short as possible (the wire length should be less than 2m), and the wire cross-section should meet the requirements of the braking resistor discharge current.
(2) The brake unit is working ...
|
|
The gateway is connected to the Delta inverter
This example is an example of the equipment used to connect a Modbubs to Profinet gateway to a Delta inverter, and the equipment used is a Siemens 1200 PLC, a Delta inverter, and a DJI Modbus to Profinet gateway.
1、Mo ...
|
|
The benefits of using an inverter – Delta inverter
1. Speed regulation of general motor: By changing the input voltage and frequency of the three-phase asynchronous motor, its speed can be controlled. Generally, when the motor is at low speed, the temperature rise becomes larger due to the decrease in the power of the cooling fan, and the motor load should be reduced according to the frequency.
2 ...
|
|
Delta inverter parameter replication error solved
1. SE2 parameter imitation error
Problem Description:
Keypad Imitation Function Fault Correction 2
Solution:
1. The Keypad imitation action is completed, and the inverter parameters are written into error
2. SE1 Parameter Imitation ...
|
|
Basic parameter setting of special inverter for wind turbine - Delta
1. Control mode:
i.e. speed control, torque control, PID control or other methods. After the control method is adopted, static or dynamic identification should generally be carried out according to the control accuracy.
2. Minimum operating frequency:
That is, the minimum speed of the motor. When the motor is working at low speed, the ...
|
|
Detection methods for Delta circuit breakers, AC contactors and frequency converters
1. Circuit breaker
A circuit breaker is a device that can be manually or automatically controlled, and is used to control the on/off of the system power supply in the equipment circuit system. When there is a suspicion that there is a defect in the electrical system of the equipment, the primary functional part of the power supply should be checked.
Under normal circumstances, when in the ON state, the input input ...
|
|
Delta's active front-end and inverter's coordination
The popularity of frequency converters has brought significant energy savings to industrial applications. However, the high-frequency switching signal generated by the inverter is easy to cause electromagnetic interference and affect the power quality. Especially in industries with large loads such as lifting and elevators, it is becoming more and more obvious.
...
|
|
How to choose Delta's servo motor
When selecting a Delta servo motor, in principle, the selection should be based on the load conditions. There are two types of loads on the motor shaft, namely damping torque and inertial load. Both loads should be calculated correctly and their values should meet the following criteria:
1) When the machine is running with no load, in the whole speed range, Delta ...
|
|
DC motor speed regulation method - Delta
There are three speed regulation methods for DC motors: armature loop string resistance, armature voltage regulation and speed regulation, and weak magnetic field speed regulation. The three speed regulation methods can achieve stepless speed regulation.
1. Armature loop string resistance
The applied resistor is connected to the armature circuit.
|
|
Servo motor speed improvement method - Delta
When many engineers debug servo motors, they often have such a problem: why is my servo motor so slow, how can I improve the speed, and how much can the maximum speed reach? The basis for the confirmation of the speed method of the servo motor: the speed of the servo motor.
...
|