When selecting a Delta servo motor, in principle, the selection should be based on the load conditions. There are two types of loads on the motor shaft, namely damping torque and inertial load. Both loads should be calculated correctly and their values should meet the following criteria:
1) When the machine tool is running at no load, the torque loaded on the shaft of the Delta servo motor should be within the continuous rated torque range of the motor, that is, the continuous working area of the torque speed characteristic curve.
2) The maximum load torque, load cycle and overload time are within the allowable range of the provided characteristic curve.
3) The torque during the acceleration/deceleration of the motor should be within the acceleration and deceleration zone (or intermittent working area).
4) For loads that require frequent, braking and periodic changes, it is necessary to check the rms value of torque over a cycle. should be less than the continuous rated torque of the motor.
5) The magnitude of the loading inertia on the axis of Delta's servo motor will affect the sensitivity of the motor and the accuracy of the entire servo system. In general, when the load is less than the rotor inertia of the motor, the above effect is not significant. However, when the load inertia reaches or even exceeds 5 times the rotor inertia, the sensitivity and response time are greatly affected. Servo amplifiers don't even work within normal adjustment ranges. Therefore, this inertia should be avoided.
|
More on that
|
Introduction of incoming reactor for inverter - Delta
Reactors are also called inductors, and when a conductor is energized, a magnetic field will be generated in a certain space scale occupied by it, so all electrical conductors that can carry current have inductance in a general sense. However, the inductance of the energized long straight conductor is small, and the magnetic field generated is not strong, so the actual reactor is conductive.
|
|
Delta inverter braking resistor selection
1. The necessity of braking resistance
If the regenerative energy that occurs during deceleration and descent in the application is too large, there is a possibility that the voltage of the main circuit inside the inverter will rise, causing damage.
Due to the built-in overvoltage maintenance function in the inverter, the overvoltage of the main circuit (O ...
|
|
Installation requirements for inverter energy consumption braking - Delta inverter
(1) The wiring interval between the braking unit and the inverter, as well as between the braking unit and the braking resistor, should be as short as possible (the wire length should be less than 2m), and the wire cross-section should meet the requirements of the braking resistor discharge current.
(2) The brake unit is working ...
|
|
Precautions for the operation of Delta servo motors
1) The AC servo motor works by means of a dedicated drive. Do not connect the commercial power supply (100/200V, 50/60Hz) directly to the line of the servo motor, otherwise the servo motor will not work properly and the servo motor will be permanently damaged.
...
|
|
The peripheral equipment of the inverter governor - Delta
When installing the inverter governor, it is necessary to first understand its use occasions and set up different peripheral equipment according to the needs of the site. The primary peripheral equipment of frequency governor is: air circuit breaker, electromagnetic contactor, communication reactor, braking resistor, DC reactor, output communication reactor, wireless ...
|
|
How to quickly master Delta servo?
1: What is the difference between servo motor and general motor?
The biggest difference between servo motors and general motors is the motor rotor and reaction equipment. The surface of the servo motor rotor is pasted with a strong magnetic steel sheet, so that it can be produced by the stator coil.
|
|
Precautions for storage of Delta inverter VFD-VE
It must be placed in a ventilated, dust-free, dry place.
The ambient temperature of the storage location must be in the range of -10°C to +40°C
The relative humidity of the storage location must be in the range of 0% to 90% and be free of dew.
...
|
|
Analysis of the power-on trip problem of Delta inverter
In life and production, leakage switches are often used. But the inverter is not used much at some times. Most manufacturers often use leakage switches as the main switch when installing switches in the workshop. When the frequency conversion control is elected, the problem comes out, and the leakage switch is always tripped after a little moment...
|
|
A brief introduction to Delta's inverters and their models
Delta's VFD drives have now established a wide range of brand awareness in the industrial automation market. Each series of products is designed for different operation needs such as torque, loss, overload, overspeed work, etc., and is adjusted according to different industrial machinery attributes; It can provide customers with a variety of choices, and a wide range of ...
|
|
Delta was awarded an "A" rating as a "Supply Chain Engagement Leader."
On February 10, CDP released its 2021 Supplier Engagement Rating; SER) As a result, Delta received the highest scores in key scoring items such as "Supply Chain Participation" (Note 1) and "Three Emissions in the Greenhouse Gas Field" (Note 2).
|
|
VFD center power electronics and control mode
1) Power electronic equipment power electronic equipment is in the circuit to play the effect of on-off and complete a variety of converter equipment, VFD is the installation of this converter, so it is with the development of the inverter equipment and unfold, the quality of the inverter equipment depends on its on-off ability, accept the on-off current and amount...
|
|
Delta linear motor driver ASDA-A2R series
In view of the rapid transformation of the industry, Delta has specially proposed a total linear motor solution, deploying various communication interfaces, extending the evolved model ASDA-A2R from ASDA-A2 as a linear horse driver, and deploying Delta's high-speed bus controller and axis card to form a complete linear motor ...
|
|
What are the problems of the inverter if it is not used for a long time - Delta
Most inverter brand products can rely on the heat of internal electrical components to remove moisture during normal use. If you don't use it for a long time, it's easy to get wet. The chip pins, penetrating resistors, capacitors, and inductor pins of the DIP package will be severely rusted or desoldered, resulting in on-resistance ...
|
|
Introduction to Delta Inverter VFD-C200 Series
Delta's VFD-C200 series inverters adopt the design concept of ultra-miniature structure: small size, compact structure, reliable performance, and optimal heat dissipation design, which is convenient for users to install and debug. Taking into account the possibilities of the industrial production environment, this inverter is made of special materials and complies with the requirements of the IEC...
|
|
Tips and methods for using PLC - Delta PLC
First, the selection of output module
The output modules are divided into transistors, triacs, and contact types:
(1) The switching speed of the transistor type is fast (generally 0.2ms), but the load can be small, about 0.2-0.3A, 24VDC, suitable for fast switching, signal contact...
|
|
Introduction to Delta's PLC maintenance knowledge
1. Delta's PLC power on running light does not light up, and the ERROR flashes, the reason may be: no program
2. Delta's PLC cannot communicate with the computer, which may be: RS23 port is broken
3. Delta's PLC power light does not light up: The power supply is bad
...
|
|
How to wire the internal control and external control of Delta inverter
How to wire the internal control and external control of Delta's inverter?
Internal control: connect the main circuit power supply RST motor UVW, press the inverter panel to start and stop. Both the command source and the frequency frequency should be selected in the panel.
External ...
|
|
Analysis of communication problems of Delta inverters
Problem Clarification:
Communication Transmission Timeout: The Modbus transmission between the VFD and the Keypad times out
Solution:
VFD does not respond to Keypad's communication commands.
1. Confirm the communication quality of the communication wiring and contacts.
2. Please use the RESET key to clear the Fault ...
|
|
Delta's DTK series thermostat product model
DTK4848C01 High brightness LCD display, 48*48, Pt resistor/thermocouple input, 4-20mA output, 1 alarm
DTK4848R01 High brightness LCD display, 48*48, Pt resistor/thermocouple input, relay output, 1 alarm
DTK4848V01 Highlight ...
|
|
Whether the inverter needs to be added to the line - Delta
The role of the "communication input reactor" of the inverter input device is mainly to improve the power factor of the communication power supply on the communication side of the input side; It is useful to eliminate the higher harmonics on the input side to avoid damage to other electrical equipment caused by voltage distortion; Eliminate the three-phase AC power phase ...
|
|