1. First of all, calculate the maximum power consumption of the computer
The power consumption of the computer is different in different operating states, such as 95W on startup, 35W on standby, and up to 480W when the game is fully loaded.
The power consumption of the power supply is changed according to the operating needs of the computer, assuming that the standby power consumption is 35W, then in the standby time, the fan is too lazy to turn, and it is 35W/h/conversion rate in an hour, and violent games, high load of the graphics card, it is possible to reach higher power consumption.
A car that can pull 10 tons of cargo does not mean that it will consume the same gasoline for empty and light loads.
2. Power conversion rate and standby power consumption
Usually the better the quality of the power supply, the less attenuation of the conversion process, the higher the conversion rate, United States there is also an 80plus, the same brand, power supply because of the PLUS level is different, the power conversion rate and price will be very different, there are many false standards, the big brand false standards are relatively less, which is why not introduce miscellaneous brands;
The conversion rate of the power supply is different under different loads, usually in the 40%-60% range of the power supply conversion rate is the highest, which is why it is recommended to buy a power supply with a slightly larger total output, the first is to use the best conversion rate, and reduce heating, fan noise, and reduce the probability of capacitor bursting, and improve the service life of the power supply;
4. Output ripples
Ripple and noise are mixed AC components in the DC output of the power supply, and if you look at it with an oscilloscope, you will see that the voltage fluctuates slightly up and down, like water ripples, so it is called ripple. Excessive ripple will interfere with the digital circuit and affect the stability of the circuit operation. Generally, the solid-state capacitor of FPCAP is filtered to reduce ripple interference, which is often used in many high-end headphones in the past.
5. Wide range of voltage support
The voltage in some areas is not stable, if there is no voltage regulator installed at home, the voltage difference between the peak power consumption period during the day and night may be more than 10V, sometimes turning on the air conditioner at night will cause the lamp to lose voltage and shine, if the voltage is not widely planned, some voltage fluctuations may lead to a lack of power supply for a spare part to produce a blue screen restart, the game is good, and the sudden restart is often the reason, this may be the most important thing for Lao Tie.
|
More on that
|
The cause of inverter heating - Delta inverter
1. The problem of the inverter and the motor itself
If the motor has been used for a long time, it is not good to clean the insulation function, or the bearing may be stuck, and it may show a large current and heat. The coupling between the motor and the load may also be worn, or the motor is unbalanced, the fixtures of the motor are loose, etc.
|
|
Delta launched an integrated control solution for layer winding
As factories move from automation to intelligence, the requirements for equipment performance and scalability are progressing day by day. In response to the rapid development of electronic engineering, transportation and mechanical engineering and other occupations, in order to quickly manufacture related product parts and components, metal coil winding technology is also being carried out at a high speed.
|
|
Important parameters of Delta inverters
The inverter is the pioneering work of Delta Automation, and it is also the largest selling product of Delta Automation. In the highly competitive market, Delta inverters have always maintained a strong growth momentum and made great achievements in the high-end product market and the economic product market. Delta continues to launch high-end products ...
|
|
Inverter power-on panel without display fault analysis - Delta
In the inverter problem, it is often encountered that the energized panel does not appear. Generally speaking, the problem of the inverter panel not showing up is usually caused by three parts, one is the poor contact of the contactor, the second is the control panel of the inverter, and the third is the damage of the power module that supplies power to the control panel.
|
|
Analysis of communication problems of Delta inverters
Problem Clarification:
Communication Transmission Timeout: The Modbus transmission between the VFD and the Keypad times out
Solution:
VFD does not respond to Keypad's communication commands.
1. Confirm the communication quality of the communication wiring and contacts.
2. Please use the RESET key to clear the Fault ...
|
|
The cause of the damage of the inverter - Delta inverter
First, the heat dissipation of the inverter is not good
In fact, we all know that too high a temperature has a damaging effect on any equipment, just like a human brain, too high a temperature will also burn out the brain, in fact, the same is true for inverters. When the temperature rises, because of the sensitivity of semiconductors to temperature, the inverter ...
|
|
Precautions before installation of Delta inverters
Delta's inverter should be thoroughly inspected for initial installation or long-term use. The items and methods to check are as follows:
1) Check whether the Delta inverter is damaged, whether the metal parts are rusty, and whether there is frost. If there is frost and condensation, it should be dry for 4 hours (60°C) or in ...
|
|
Delta's touch screen downloads programs and communication settings
1. Touch screen download program
(1) Device software DOPSoft;
(2) The communication line uses a square port data line;
(3) device drive;
(4) Configuration screen;
(5) In the Stuff, select Download All Materials.
2. Communication settings
(1) Touch screen settings
...
|
|
What are the problems of the inverter if it is not used for a long time - Delta
Most inverter brand products can rely on the heat of internal electrical components to remove moisture during normal use. If you don't use it for a long time, it's easy to get wet. The chip pins, penetrating resistors, capacitors, and inductor pins of the DIP package will be severely rusted or desoldered, resulting in on-resistance ...
|
|
Solution: Delta's inverter operation error
There are many setting parameters of the inverter, each parameter has a certain selection scale, and the inverter can not work normally due to the improper setting of a single parameter is often encountered in the application, therefore, the relevant parameters must be set correctly.
...
|
|
Delta's DTK series thermostat product model
DTK4848C01 High brightness LCD display, 48*48, Pt resistor/thermocouple input, 4-20mA output, 1 alarm
DTK4848R01 High brightness LCD display, 48*48, Pt resistor/thermocouple input, relay output, 1 alarm
DTK4848V01 Highlight ...
|
|
A brief introduction to Delta's inverters and their models
Delta's VFD drives have now established a wide range of brand awareness in the industrial automation market. Each series of products is designed for different operation needs such as torque, loss, overload, overspeed work, etc., and is adjusted according to different industrial machinery attributes; It can provide customers with a variety of choices, and a wide range of ...
|
|
The inverter has a function – a Delta inverter
1. Soft start is energy-saving
The hard start of the motor will cause a serious impact on the power grid, and it will also require too high the capacity of the power grid, and the large current generated when the motor is started and the sensation will cause great damage to the baffle and valve, and the service life of the equipment and pipeline will be extremely unlucky. And the use of inverter energy-saving devices ...
|
|
Delta's Ultron NT series UPS escorts flight safety at international airports
The rapid development of the national economy has opened up a broad shopping mall space for the growth of the civil aviation industry. In order to meet the surge in the number of flights, an international airport in Northwest China has invested in the third phase of the expansion project, and has been listed as the "number one project" for civil aviation development and the "benchmark demonstration project" for national civil aviation.
|
|
Characteristics of common models of Delta inverters
Delta MS300 Inverter Series: Delta's compact standard vector-operated inverter MS300 combines the advantages of miniaturization, high functionality, high trust, and simple installation, transforming every investment in industrial resources into abundant results. Optimized structure with lock-free screw terminals to plan the supply of bento ...
|
|
Delta's PLC-Based motion controller AX3 series
With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud channels are showing a trend of a hundred flowers blooming, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... In order to ...
|
|
Introduction to the inverter selection strategy - Delta inverter
1. Ability to adapt to the environment
1.1 Ability to adapt to grid voltage fluctuations
When the motor on the bus starts in a group, when the largest motor unit on the bus starts, the influence on the operation of the inverter, which is related to the input voltage fluctuation range parameters promised by the inverter.
|
|
Precautions for the operation of Delta servo motors
1) The AC servo motor works by means of a dedicated drive. Do not connect the commercial power supply (100/200V, 50/60Hz) directly to the line of the servo motor, otherwise the servo motor will not work properly and the servo motor will be permanently damaged.
...
|
|
Measures to avoid soft failure of inverters - Delta
The ways to reduce the soft fault of the inverter are: 1. Detect the overvoltage and undervoltage of the inverter; 2. Detecting overcurrent is the most frequent phenomenon of frequency conversion alarm.
Generally, the overvoltage alarm is generally presented at the time of shutdown, and the primary reason is that the deceleration time is too short or the braking resistance and braking unit have ...
|
|
The difference between a general-purpose inverter and a vector inverter - Delta
There are two main differences between vector inverter and general inverter, the first is high control accuracy, and the other is high output torque at low speed. It can output 150%-200% of the rated torque. It should be vector frequency conversion is to decompose the motor current into D-axis current and Q-axis current, where D-axis current is excitation current ...
|
|