1. Circuit breaker

A circuit breaker is a device that can be manually or automatically controlled, and is used to control the on/off of the system power supply in the equipment circuit system. When there is a suspicion that there is a defect in the electrical system of the equipment, the primary functional part of the power supply should be checked.

Under normal circumstances, when the ON state is on, the input and output terminals are also in the ON state (that is, powered on). When it is closed, the input and output terminals are also closed.

When the circuit breaker is overhauled in the circuit, the on-off condition characteristics of the circuit breaker in the case of power failure are used, and the resistance value between the input and output of the circuit breaker can be measured by a multimeter, and its quality can be judged.

Under normal circumstances, when the Delixi circuit breaker is turned off, the resistance between the input and output terminals should be infinity; When the circuit breaker is turned on, the resistance between its input and output should be zero; If this rule is not met, it is clarified that the circuit breaker is damaged and should be replaced with a circuit breaker of the same standard.

                            Detection methods for Delta circuit breakers, AC contactors and frequency converters

2. AC contactor

The AC contactor is an important element in the circuit system, and its internal main contact is mainly used to control the on-off condition of the equipment load, and the auxiliary contact is used to execute the control command.

The AC contactor is mainly installed in the control distribution cabinet in the circuit system, which is used to receive the signal from the control terminal, and then the electrical contact action of the coil (normally open contact closed, normally closed contact open), and the load is energized at the beginning end. When the coil is de-energized and released, all contacts reset and the load is de-energized and aborted.

If the AC contactor is damaged, the equipment cannot be started or operated normally. The first way to judge its function is to use a multimeter to judge whether the resistance between the coil and the corresponding pin is normal when the AC contactor is powered off.

When the internal coil of the AC contactor is energized, its internal contact will act contrary to the initial condition, that is, the normally open contact is closed and the normally closed contact is disconnected; When the internal coil is de-energized, its internal contacts are reset and the initial condition is restored.

Therefore, when testing the contactor, it is necessary to test the resistance of its internal coil and the resistance of its internal contacts in the open and closed conditions. Because of the contactor power-off test, the resistance value of the normally open contact is infinite. When the switch button on the top of the communication contactor is pressed, the normally open contact closes and its resistance value is usually zero ohms.

3. Inverter

In the equipment circuit system, the circuit system controlled by the frequency converter is installed in the control box. As the central control component, the inverter is mainly used to control the operation status of various motors and compressors in the system.

Therefore, when the inverter is abnormal, the entire inverter control system will also be abnormal. Whether the function of the inverter is normal or not can be judged by detecting the power supply voltage and output control signal of the inverter.

If the input voltage is normal and there is no frequency conversion drive signal output, it means that the frequency converter itself is abnormal.

Because an inverter is a delicate electronic device that includes a variety of circuits inside, it is possible to troubleshoot the fault codes displayed on the display in addition to the inputs and outputs, such as the Mitsubishi FR-A700 inverter, when testing it. If the display shows "ELF", it indicates that there is a problem with the output phase of the inverter. The output terminal should be connected normally, and the value selected by the output phase failure protection should be checked to see if it is normal.

The service life of the inverter will also be affected by the external environment, such as temperature, humidity, etc. Therefore, the location of the inverter should be in accordance with the conditions of its surroundings. In addition, care should be taken when connecting the cables of the device, as the inverter can also be damaged if the connection is made incorrectly. To prevent electric shock, it is also necessary to ground the inverter grounding terminal.

More on that
The technical advantages of the three-axis positioner - Delta The technical advantages of the three-axis positioner - Delta

1. The welding station is actively handed over, and the operator has been loading and unloading parts in a fixed position, which effectively reduces the labor and logistics intensity of the operator, and the welding products of the whole set of equipment have strong compatibility and strong automatic welding scalability. 2. All ...

Delta's inverter fault warning solution Delta's inverter fault warning solution

Product series: CP/CH/CT/C2000/C200/MS300/MH300/VE/ED/VJ Fault Codes: noCL Fault clarification: The lack of oil is correct Solution: 1. Check the fuel level of the fuel tank 2. Check whether there is any leakage on the oil road.

Delta launched the MZM, a high-power positional drive system Delta launched the MZM, a high-power positional drive system

Driven by consumption promotion and product diversification, the manufacturing industry's demand for automation and intelligent promotion in production and processing is also increasing. In the production process, the processing of "large and heavy" items is often difficult to control accurately, and the deviation of orientation is not as easy as that of "small" items. To this end ...

Precautions for transportation, installation and storage – Delta Precautions for transportation, installation and storage – Delta

1) When taking out or placing the servo motor, it is not possible to only pull the wire and drag the motor or only hold the rotating shaft core. 2) Do not hit the shaft directly, e.g. by tapping or hammering, as this may cause damage to the shaft and the encoder attached to the opposite side of the shaft. 3) Give the shaft core ...

Intelligent thermostat adjustment method - Delta Intelligent thermostat adjustment method - Delta

1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET key digital tube character beginning flash, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again The appearance back ...

Delta's PLC-Based motion controller AX3 series Delta's PLC-Based motion controller AX3 series

With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud channels are showing a trend of hundreds of schools of thought, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... In order to ...

Inverter power-on panel without display fault analysis - Delta Inverter power-on panel without display fault analysis - Delta

In the inverter problem, it is often encountered that the energized panel does not appear. Generally speaking, the problem of the inverter panel not showing up is usually caused by three parts, one is the poor contact of the contactor, the second is the control panel of the inverter, and the third is the damage of the power module that supplies power to the control panel.

Inverter performance test method - Delta Inverter performance test method - Delta

As we all know, the inverter has many maintenance functions, such as overcurrent, overvoltage, overload maintenance and so on. With the continuous improvement of industrial automation, frequency converters have also been widely used. This article will explain to you how to use a multimeter to measure the quality of the inverter. Need...

Brand inverter modifies the power method - Delta Brand inverter modifies the power method - Delta

What are the benefits of inverter power correction? Many brands of inverter power boards, driver boards, and motherboards can be universal, as long as the type, volume, and hardware are the same, and the desired power and voltage value can be obtained by correcting the manufacturer's parameters.

Repair of Delta inverter problemsView items Repair of Delta inverter problemsView items

Daily inspection item 1 of Delta's inverter problem repair: Check whether there is any abnormal change in the sound of the motor during operation, including whether oscillation occurs during the operation of the motor. Delta's daily inspection of inverter problem repair ...

Several veins of the inverter circuit - Delta inverter Several veins of the inverter circuit - Delta inverter

1. Vibration circuit: the leakage-source and R4 of the main winding N1 and Q1 of the switching transformer are the channels of the power supply operation current; R1 provides the starting current; The self-powered windings N2, D1, and C1 constitute the power supply voltage of the vibrating chip. The normal operation of these three links is the prerequisite for the power supply to vibrate.

Principles of daily protection and maintenance of Delta inverters Principles of daily protection and maintenance of Delta inverters

1. Record the operation data and shortcomings of the Delta: The operation data of the Delta inverter and the motor should be recorded every day, including the output frequency, output current, output voltage, DC voltage inside the inverter, radiator temperature and other parameters, and compare them with reasonable data, so as to facilitate early detection of defects.

Introduction to Delta's DVPSCM52-SL communication module Introduction to Delta's DVPSCM52-SL communication module

Recently, Delta Group has made a big hit in the field of building automation with the launch of the DVPSCM52-SL, a slave communication module that supports BACnet MS/TP (Building Automation Control Network Communication Protocol). Building automation system is an indispensable part of intelligent building.

Delta's Amplon N series UPS ensures the safety of electricity consumption in pharmaceutical production lines Delta's Amplon N series UPS ensures the safety of electricity consumption in pharmaceutical production lines

In recent years, in response to the development trend of automation, informatization and intelligence, pharmaceutical companies have continuously innovated, transformed and upgraded, selected fully automated intelligent production lines, accelerated the upgrading of equipment in the pharmaceutical industry, and completed the use of smart pharmaceutical technology for green, safe, high-quality and low-consumption development in the pharmaceutical industry.

Analysis of the power-on trip problem of Delta inverter Analysis of the power-on trip problem of Delta inverter

In life and production, leakage switches are often used. But the inverter is not used much at some times. Most manufacturers often use leakage switches as the main switch when installing switches in the workshop. When the frequency conversion control is elected, the problem comes out, and the leakage switch is always tripped after a little moment...

Correct use of Delta inverter in operation Correct use of Delta inverter in operation

(1) When the speed of the motor is controlled by the Delta inverter, the noise and temperature rise of the motor are higher than that of the frequency of the motor. When the motor is running at low speed, because the speed of the motor blades is low, the temperature rise of the motor becomes high.

Factors affecting Delta's inverter motors and countermeasures Factors affecting Delta's inverter motors and countermeasures

1. The influence of leakage current on the motor and countermeasures If the wiring length is very long, the stray capacitance between the wires will increase, resulting in leakage current. It will initiate overcurrent maintenance, increase leakage current or not ensure the correctness of the current display. The bad situation is that the inverter will ...

Solution to Delta inverter fault CE1 and CE2 Solution to Delta inverter fault CE1 and CE2

Product range: CP/CH/CT/C2000/C200/MS300/MH300/VE/ED/VJ Problem Code: CE1 Problem Description: Communication is abnormal Solution: 1. Communication error: RS-485 Modbus function code may be faulty ...

Inverter application for heat dissipation to solve the precautions - Delta Inverter application for heat dissipation to solve the precautions - Delta

The transformer DC resistance tester uses the 32-bit ARM core as the core of processing, controls the whole machine, and automatically completes the functions of self-calibration, current stabilization judgment, data processing, resistance value display, etc., and can measure the DC resistance of various types of transformers and transformers. ...

TIMTOS x TMTS 2022 - Delta's Exhibit Highlights TIMTOS x TMTS 2022 - Delta's Exhibit Highlights

Intelligent machining solution plan Intelligent machinery is an important step towards intelligent manufacturing, in order to help manufacturers improve productivity or complete a few diverse forms of production, Delta will exhibit the intelligent processing solution plan at TIMTOS x TMTS 2022, which will be used to communicate with industrial-grade managed Ethernet networking.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top