The reason for the shaking of the inverter for the motor - Delta
When using the motor dragged by the inverter, sometimes the motor flutters and the over-fire flutter may burn out the motor and cause immeasurable losses. So what is the reason for this phenomenon?
1. The motor is damaged ...
|
|
Delta has always been the shipment champion in Taiwan's inverter market
Based on trend forces, the sales market of solar power generation in Taiwan was analyzed. In the first half of 2019, AUO ranked second, while third-ranked Canada Solar entered the top three for the first time.
Compared with the previous year, the sales market in Taiwan, China in the first half of 2019 was in the total delivery of common decoration ...
|
|
The basic control loop of Delta's inverter
There are two fundamental circuits for communicating with external signals: analog and digital:
1. 4-20mA current signal loop (imitation); 1 - 5V/0 - 5V voltage signal loop (imitation).
2. Switch signal circuit, inverter start and stop command, forward rotation command, etc.
|
|
Delta's DTK series thermostat product model
DTK4848C01 High brightness LCD display, 48*48, Pt resistor/thermocouple input, 4-20mA output, 1 alarm
DTK4848R01 High brightness LCD display, 48*48, Pt resistor/thermocouple input, relay output, 1 alarm
DTK4848V01 Highlight ...
|
|
Delta's inverter failure analysis
1. Fault code:
SE1 parameter replication error
Fault Description:
Keypad replication function error correct
Solution:
Keypad replication action errors, including communication delays, communication errors (Keypad received FF86 errors), and parameter value errors
...
|
|
Delta's inverter energy-saving method
Delta's inverter energy-saving method is mainly manifested in the application of fans, pumps, and hoists. In order to ensure the reliability of production, all kinds of production machinery are designed with power drive, and there is a certain amount of surplus.
Power Factor Supplement ...
|
|
Safety precautions for Delta servo motors
Delta's servo motor system is planned for industrial use, and it is necessary to have a full understanding of the motor standards and operation manuals before operating the motor. For the safety of the operator and the mechanical equipment, and to ensure that the communication motor can be used correctly, please read this safety precaution before installing the machine.
...
|
|
The peripheral equipment of the inverter governor - Delta
When installing the inverter governor, it is necessary to first understand its use occasions and set up different peripheral equipment according to the needs of the site. The primary peripheral equipment of frequency governor is: air circuit breaker, electromagnetic contactor, communication reactor, braking resistor, DC reactor, output communication reactor, wireless ...
|
|
Delta's inverter power-on debugging method
After the inverter is installed, disconnect the output of the inverter, use the diode file of the digital meter to measure the input and output of the inverter before the power is not turned on, ensure that there is no short circuit, and then turn on the working power supply of the inverter.
|
|
Analysis of misunderstandings in the application of Delta inverters
The capacity selection of the inverter is based on the rated power of the motor
Myth: The capacity selection of the inverter is based on the rated power of the motor
Compared with the motor, the price of the frequency converter is the most expensive, so under the premise of ensuring safe and reliable operation, the frequency conversion can be reasonably reduced.
|
|
Correct use of Delta inverter in operation
(1) When the speed of the motor is controlled by the Delta inverter, the noise and temperature rise of the motor are higher than that of the frequency of the motor. When the motor is running at low speed, because the speed of the motor blades is low, the temperature rise of the motor becomes high.
|
|
Introduction to Delta's PLC maintenance knowledge
1. Delta's PLC power on running light does not light up, and the ERROR flashes, the reason may be: no program
2. Delta's PLC cannot communicate with the computer, which may be: RS23 port is broken
3. Delta's PLC power light does not light up: The power supply is bad
...
|
|
Several veins of the inverter circuit - Delta inverter
1. Vibration circuit: the leakage-source and R4 of the main winding N1 and Q1 of the switching transformer are the channels of the power supply operation current; R1 provides the starting current; The self-powered windings N2, D1, and C1 constitute the power supply voltage of the vibrating chip. The normal operation of these three links is the prerequisite for the power supply to vibrate.
|
|
The reason for the abnormal operation of Delta's inverter
There are many setting parameters of the inverter, and each parameter has a certain selection scale, and the inverter can not operate normally due to the improper setting of a single parameter is often encountered in the application, therefore, the relevant parameters must be correctly set.
...
|
|
Delta-B series inverter inverter output module is damaged and the drive circuit is damaged
Delta-B series inverter inverter output module is damaged and the drive circuit is seriously damaged: the drive integrated circuit T250V or burst, or the output terminal and the power supply ground are short-circuited, the filter capacitor is sprayed, the regulator tube is broken down or open, the resistance is open or the resistance value increases, and the circuit board carbonization is damaged.
|
|
Repair of Delta inverter problemsView items
Daily inspection item 1 of Delta's inverter problem repair:
Check whether there is any abnormal change in the sound of the motor during operation, including whether oscillation occurs during the operation of the motor.
Delta's daily inspection of inverter problem repair ...
|
|
The gateway is connected to the Delta inverter
This example is an example of the equipment used to connect a Modbubs to Profinet gateway to a Delta inverter, and the equipment used is a Siemens 1200 PLC, a Delta inverter, and a DJI Modbus to Profinet gateway.
1、Mo ...
|
|
Whether the inverter needs to be added to the line - Delta
The role of the "communication input reactor" of the inverter input device is mainly to improve the power factor of the communication power supply on the communication side of the input side; It is useful to eliminate the higher harmonics on the input side to avoid damage to other electrical equipment caused by voltage distortion; Eliminate the three-phase AC power phase ...
|
|
What are the problems of the inverter if it is not used for a long time - Delta
Most inverter brand products can rely on the heat of internal electrical components to remove moisture during normal use. If you don't use it for a long time, it's easy to get wet. The chip pins, penetrating resistors, capacitors, and inductor pins of the DIP package will be severely rusted or desoldered, resulting in on-resistance ...
|
|
Introduction to common models and parameters of Delta touch screens
There are many types of Delta contact screens, of course, the parameters of different types are different, and the most important product is DOP-B03S201. This product is a 4.3-inch screen, its aspect ratio is 16:9, the screen is made of TFT raw materials, and its resolution can reach 480X ...
|