New Delhi, September 2, 2010 – Delta Group, the world's largest supplier of switched-mode power supplies and brushless DC fans, is committed to innovation, energy efficiency and environmental protection by launching a new and advanced high-performance ASDA-A2 series of servo motors and servo drives for motion control and network communication in India. Due to the current trend towards motion control to bring the control command source closer to the actuator, Delta has developed the new ASDA-A2 series to provide superior motion control while eliminating external manipulators. The purpose of these state-of-the-art motors and drives is to meet the requirements of motion control in industrial automation and high-precision positioning control.
The ASDA-A2 series has a built-in electronic cam (E-cam) function, providing the best solution for flying shear, rotary plugging and synchronous motion use. The ASDA-A2 is available in PR form factor and with a CANopen interface. The new azimuth control PR form is a common and important function, which provides a variety of control forms to improve the system function. The ASDA-A2 series also provides CANopen (1M bps) high-speed network communication interface, which greatly reduces the difficulty of controller program design and can realize multi-axis parallel high-speed control. Full closed-loop control, automatic notch filter, ASDA-A2's vibration pushing, and rack control functions help to perform complex movements that require high-precision, peaceful and stable operation. The ASDA-A2 is equipped with a 20-bit high-resolution encoder for precise positioning and excellent high-speed pulse capture and comparison for optimal support for stepless positioning.
Manish Walia, Sales Director, Delta Group-Industrial Automation Business Unit for India and SAARC, said, "The demand from machine builders for greater precision and azimuth control has driven the rapid growth of the motion business in India. Together, the demand for progressive productivity is increasing across market segments. ”。 Delta India is active in concentrating on various applications in the machine tool, packaging and textile sectors and is committed to exponential growth of the servo motor and drive product line.
These motors and drives are rated for features such as a frequency response of up to 1kHz, innovative editing software, and high-speed PC monitoring (similar to a digital oscilloscope) that greatly improve the functionality of the ASDA-A2 family of communication servo motors and drives. ASDA-A2 is also widely used in engraving machines, cutting machines, feeders, high-speed label inserting machines, etc. The ASDA-A2 series of AC servo motors and drives is the ultimate servo system, providing a comprehensive solution for a wide range of machine tools and industrial use. Delta believes that India has many opportunities in automation because it wants automation to improve productivity and precision. Delta offers the industry's broadest range of industrial automation products and is highly competitive in the OEM space.
|
More on that
|
Delta's inverter and output reactor function
input/output reactor for frequency conversion speed regulation; Because the inverter is often affected by the impact of inrush current and surge voltage in the process of driving the inverter motor operation governor, which will seriously damage the function and service life of the inverter and the motor, so it is necessary to install a transmission system in front of it.
|
|
Delta's key steps in inverter maintenance
First, the maintenance of the inverter must first check whether the sound in the operation of the motor has changed abnormally, including, whether the motor is in operation to form a sensation.
2. Check whether the natural environment of the inverter installation has changed. For example, whether the operating temperature is normal. Learn more about Delta's inverter ...
|
|
What are the problems of the inverter if it is not used for a long time - Delta
Most inverter brand products can rely on the heat of internal electrical components to remove moisture during normal use. If you don't use it for a long time, it's easy to get wet. The chip pins, penetrating resistors, capacitors, and inductor pins of the DIP package will be severely rusted or desoldered, resulting in on-resistance ...
|
|
Delta's inverter composition and function
Delta inverter is a device that converts the power supply (50Hz or 60Hz) into a communication power supply of various frequencies to complete the variable speed operation of the motor, in which the control circuit completes the control of the main circuit, the rectifier circuit converts the communication power into direct current, and the output input of the DC center circuit to the rectifier circuit is ...
|
|
Introduction and features of Delta PLC
Delta's programmable controllers, also known as Delta programmables, delta programmable controllers, delta programmable controllers, etc., are electronic devices specially designed by Delta for the industrial automation category to complete digital operations. Delta's PLC uses programmable memory to store execution logic inside it.
|
|
Correct use of Delta inverter in operation
(1) When the speed of the motor is controlled by the Delta inverter, the noise and temperature rise of the motor are higher than that of the frequency of the motor. When the motor is running at low speed, because the speed of the motor blades is low, the temperature rise of the motor becomes high.
|
|
The benefits of using an inverter – Delta inverter
1. Speed regulation of general motor: By changing the input voltage and frequency of the three-phase asynchronous motor, its speed can be controlled. Generally, when the motor is at low speed, the temperature rise becomes larger due to the decrease in the power of the cooling fan, and the motor load should be reduced according to the frequency.
2 ...
|
|
Delta's inverter fault warning solution
Product series: CP/CH/CT/C2000/C200/MS300/MH300/VE/ED/VJ
Fault Codes:
noCL
Fault clarification:
The lack of oil is correct
Solution:
1. Check the fuel level of the fuel tank
2. Check whether there is any leakage on the oil road.
|
|
Failure analysis of Delta inverter VFD-VL series
Fault 1: Overcurrent in acceleration
Clarification: Overcurrent in acceleration
Solution 1: Check whether the wiring from U-V-W to the motor is poorly insulated;
2: Increase acceleration and deceleration time;
3: Replace the inverter with a larger output capacity;
4: Reduced (P54) torque ...
|
|
Inverter acceleration and deceleration mode selection - Delta
Inverter acceleration form and deceleration form selection, also known as acceleration and deceleration curve selection. Generally, there are several forms of inverter, such as linear, S-shaped, semi-S-shaped, etc., and the characteristics and uses of each form are as follows:
1. Linear form
This form makes the inverter's ...
|
|
DC motor speed regulation method - Delta
There are three speed regulation methods for DC motors: armature loop string resistance, armature voltage regulation and speed regulation, and weak magnetic field speed regulation. The three speed regulation methods can achieve stepless speed regulation.
1. Armature loop string resistance
The applied resistor is connected to the armature circuit.
|
|
Delta's SCARA industrial robots help replace machines in the electronics manufacturing industry
Project Background
At present, electronic products such as mobile phones, computers, and IPads have become the standard in people's lives, which also promotes the rapid development of the electronic manufacturing industry. PCB (printed circuit board) is an important component in electronic products, with the trend of electronic products towards high-end, miniaturization ...
|
|
Voltage regulator selection method - Delta inverter
1. Capacity safety factor
The AC regulated power supply is based on the output apparent power (kVA) as the nominal rated capacity, and the load is not purely resistive under normal circumstances, that is, the power factor COS¢≠1, and the active power that the regulator can output in practice kW = capacity (kVA) × COS¢. So in the real ...
|
|
The case of Delta's multi-axis motion controller
The non-standard manipulator can be customized according to the practical needs of customers, because the non-standard manipulator has no specifications to follow, and there is no such kinematic model in the controller, so the development of the control system is difficult. Delta recently provided non-standard manipulators for pharmaceutical board manufacturers to supply control solutions ...
|
|
Precautions for initial installation of Delta inverters
Delta's inverters should be thoroughly inspected for the first time or after long-term installation. The items and methods of inspection are as follows:
1) Check whether the Delta inverter is damaged, whether the metal parts are rusty, and whether there is frost. If there is frost and condensation, it should be dried for 4 hours (60°C) or ...
|
|
Delta's Amplon N series UPS ensures the safety of electricity consumption in pharmaceutical production lines
In recent years, in response to the development trend of automation, informatization and intelligence, pharmaceutical companies have continuously innovated, transformed and upgraded, selected fully automated intelligent production lines, accelerated the upgrading of equipment in the pharmaceutical industry, and completed the use of smart pharmaceutical technology for green, safe, high-quality and low-consumption development in the pharmaceutical industry.
|
|
Cause of Servo Motor Failure – Delta
1. The motor is broken shaft
1. The cause of the problem
(1) Unreasonable mechanical design leads to excessive radial load force;
(2) The load end is stuck or severely overloaded;
(3) The motor and reducer are not centered when installed.
2. Eliminate problems
(1) Check the ...
|
|
Delta's inverter process setting
1. Restore the inverter to factory settings, press the "ENTER" button to enter the parameter setting interface, and press it continuously until it is 00-00 and then stop. Press the number up button to change to 00-02. Press the "ENTER" key again, the panel value will show 0, press the number up key to change it to 9. Press the "ENTER" key, break ...
|
|
The inverter sets the characteristic parameters of the motor
1. Parameters to be set for the motor
When the inverter (hereafter referred to as the -VFD) is operating in the "vector control" (F0-03=1) mode, it is highly dependent on accurate motor parameters, which is one of the important differences from the "VF controlled" (F0-03=2) mode. In order for the VFD to have outstanding driving ...
|
|
The inverter has a built-in PLC function - Delta
PLC progressive scanning standard work preparation.
Abundant programming language: instruction statements; ladder diagram; SFC。
Abundant instruction statements: 45 instruction varieties, including 28 root instructions and 17 usage instructions.
350 step law capacity.
uS-level root directives ...
|
|