RLC Thermostat – Precautions for Thermostat Operation

Create Date: 2024-8-30 12:03:23|Source: RKC

1) Measure the function

Its temperature measurement scale is mainly between -20 °C and 80 °C, and the humidity measurement scale is mainly between 20% RH and 99% RH. In addition, it has a temperature resolution of 1°C and a humidity of 1%RH.

2) Parameters and data display functions

The display of the temperature and humidity controller uses two rows of high-brightness digital tubes, and the user can read them at a glance - the upper row is a four-digit high-brightness red digital tube, which is mainly used to display temperature data and set parameters, and when it is to display temperature data, it is identified as "°C"; The lower row is a four-digit high-brightness red digital tube, which is mainly used to display humidity data and set parameter values, and when it is to display humidity data, it is marked with "%RH".

3) Heating and defrosting function

The heating defrost system software actively discriminates heating and defrosting, which is the active output; The heater can be aluminum alloy heater or other types of heater.

4) Disconnection alarm function

When the heater is disconnected or the heater fails, the system software actively discriminates and outputs the alarm signal as a passive node.

5) Signal indication function

(1) Heating indication: when the system is heated, the panel heating indicator light is on;

(2) Exhaust indication: when the exhaust air is cooled, the panel exhaust indicator light is on;

(3) Alarm indication: when the heater is disconnected or the heater fails, the panel alarm LED is on.

6) Sensor characteristics

The temperature and humidity controller adopts imported high-performance, anti-corrosion, high-reliability, high-sensitivity humidity sensor, temperature IC sensor, wide scale and good linearity.

7) The user can set the upper and lower limits of temperature and humidity arbitrarily, which is convenient for different users or different occasions.

8) When the parameter value is set every time, the parameter will actively save the data, and the data will not be lost after power failure.
RLC Thermostat – Precautions for Thermostat Operation

More on that
Analysis of common fault causes of RKC temperature controller Analysis of common fault causes of RKC temperature controller

1. The power indication is normal, but the temperature controller has no screen display. Most of this fault is caused by the heating of the voltage regulator element (7805 or 7812) on the thermostat during long-term use, which causes the solder joint to show a breakpoint, and sometimes it is caused by the phenomenon of virtual soldering at the factory. 2. Temperature controller ...

The debugging method of the temperature controller The debugging method of the temperature controller

Generally, there are three buttons to provide the need for setting, one is the Set button, press it once to enter the setting state. The other two offer upward and downward temperature adjustments, which can be adjusted to any temperature point. After adjusting to the desired temperature point, press the Set button again to confirm. 1. Turn on the smart thermostat ...

Common faults and solutions of RKC temperature controllers Common faults and solutions of RKC temperature controllers

1. The power indication is normal, but the temperature controller has no screen display. Most of this fault is caused by the heating of the voltage regulator element (7805 or 7812) on the thermostat during long-term use, which leads to the breakpoint of the solder joint, and sometimes it is caused by the phenomenon of virtual soldering at the factory, and the main re-soldering can be done. 2. Temperature controller ...

RHK thermostat – a rapid detection method for common air conditioner thermostats RHK thermostat – a rapid detection method for common air conditioner thermostats

1. Bellows or diaphragm air conditioner thermostat Fault Symptom: Poor contact or burning, resulting in the circuit cannot be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; The leakage of the thermostat in the temperature sensing chamber causes the contact to fail to operate and lose control ...

RKC thermostat REX-C400 model settings and parameter instructions RKC thermostat REX-C400 model settings and parameter instructions

Japan RIKA RKC REX-C400 temperature controller product introduction REX-C400 Digital Thermostat RKC PID Temperature Controller Thermostat (SSR Output) + Type K Thermocouple + *Large 40A SSR Relay 1. Dual display set temperature and process temperature 2. General Digital Programmable Temperature ...

What should I pay attention to when operating the RKC thermostat? What should I pay attention to when operating the RKC thermostat?

The instrument can be cleaned only after the power is off; To remove stains from the monitor, use a soft cloth or cotton paper; The display is easy to be scratched, and it is forbidden to use hard objects to operate the panel buttons, otherwise the keys will be damaged or scratched. ...

RKG thermostat - an introduction to the characteristics of digital displays RKG thermostat - an introduction to the characteristics of digital displays

1) It is a display of the common cathode. It uses the principle of the positive electrode as the segmented input, with the ground wire as the common output, and the segmented input is valid as a high-level input. 2) It is a display with a common anode. It uses an anode as an aggregate input, and in contrast to the common cathode, the segment is effective at a low level output ...

RHK thermostat - the thermostat shows the reasons for the deviation between the temperature and the actual temperature and the solution RHK thermostat - the thermostat shows the reasons for the deviation between the temperature and the actual temperature and the solution

The thermostat shows a nonlinear relationship between the temperature and the actual temperature deviation: (1) The input type of the thermostat is selected incorrectly; (2) There is no calibration or calibration error in the analog input; (3) There is interference in the thermostat; (4) There is interference with thermocouples; (5) The use of quality is not ...

Physical and chemical RK C thermostat - dry-type transformer thermostat shows fault handling methods Physical and chemical RK C thermostat - dry-type transformer thermostat shows fault handling methods

1. The dry-type transformer thermostat does not appear Cause of failure: (1) The power supply of the thermostat is not connected; (2) The fuse is blown out. Solution: (1) Turn on the power supply; (2) Replace the fuse. 2. The dry-type transformer thermostat shows that one or three phases are shining and showing "-OP-" ...

RRKC thermostat wiring installation and some precautions RRKC thermostat wiring installation and some precautions

The rkc controller was developed by Japan and is mainly used in plastics and stoves. Of course, it is also widely used in China's industry, there are many people who do not know much about the rkc controller, and some even feel unfamiliar.

RKC Thermostat – Teach you how to choose a thermostat RKC Thermostat – Teach you how to choose a thermostat

(1) Size selection When replacing the thermostat, choose according to the original size; The newly added thermostat should take into account the overall coordination of the cabinet installed, too large to fit, too small to see the display, the same function of the thermostat, the price of large volume will be more expensive, small size may function expansion...

RLC thermostat – the wiring method of the thermostat RLC thermostat – the wiring method of the thermostat

Many household appliances and large-scale equipment products will be installed in the use of thermostats, thermostats will be combined with the change of ambient temperature in the switch when working physical deformation, which will produce some special effects, resulting in conduction or disconnection action, in order to achieve automatic ...

RKG thermostat – how the temperature controller sets the parameters RKG thermostat – how the temperature controller sets the parameters

1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

RLC thermostats – the classification of thermostats and their detailed introduction RLC thermostats – the classification of thermostats and their detailed introduction

1. Sudden jump thermostat The type of various sudden thermostats is collectively called KSD, such as KSD301, KSD302, etc., the thermostat is a new type of bimetal thermostat, mainly as a variety of electric heating products with overheat protection, generally connected with the thermal fuse in series, sudden temperature ...

RLC Thermostat - Overview and characteristics of mechanical thermostats RLC Thermostat - Overview and characteristics of mechanical thermostats

Mechanical thermostats are suitable for indoor temperature control in industrial, commercial and residential buildings. The mechanical thermostat uses an inflatable diaphragm box to sense the temperature and compare it with the user's set temperature to automatically control the air conditioning equipment to achieve the purpose of indoor constant temperature. For commercial, industrial and civil construction, available ...

RKC Level Gauge – Some installation requirements for pontoon level gauges RKC Level Gauge – Some installation requirements for pontoon level gauges

1. The installation of the level gauge must be vertical to ensure that the inner pontoon can move up and down freely in the pipe body. 2. Install a shut-off valve between the container and the liquid level gauge to clean and overhaul the liquid level timing to cut off the material. 3. No magnets are allowed to approach around the main body of the pontoon level gauge, otherwise ...

RKC Thermostat – How can a thermostat be broken? RKC Thermostat – How can a thermostat be broken?

First, the temperature does not appear 1. Fault with the temperature sensor If the temperature probe of the temperature sensor breaks or the wire is broken, the sensor does not have a digital display when the temperature sensor is connected, but only shows the "----" and sounds an alarm.

RHK thermostat – a rapid detection method for common air conditioner thermostats RHK thermostat – a rapid detection method for common air conditioner thermostats

1. Bellows or diaphragm air conditioner thermostat 1. Fault phenomenon: poor contact or burning, resulting in the circuit can not be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; The thermostat in the temperature sensing chamber leaks, causing the contact to fail to operate and lose control. ...

Specifications and models of RKC thermostats Specifications and models of RKC thermostats

1. RH400 size: 48*96, depth 60, about 250g 1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L 2. Temperature measurement heat resistance input: PT100, JPT100 3. Tributary voltage: DC0 - DC5V, DC1 - DC5V ...

Introduction to the functions of the RKC temperature control meter Introduction to the functions of the RKC temperature control meter

(1) RH400 size: 48*96, depth 60, about 250g Details: ●A variety of input types are available: 1) Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L 2) Temperature measurement RTD input: PT100, JPT100...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top