1. Bellows or diaphragm air conditioner thermostat
Fault Symptom:
Poor contact or burning, resulting in the circuit cannot be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; The thermostat in the temperature sensing chamber leaks, causing the contact to fail to operate and lose control.
Maintenance method:
After turning the knob of the air conditioner thermostat in the forward and opposite directions several times, use the multimeter R×l gear to measure the two terminals of the temperature controller in the on-on state, if the resistance value is very small, it indicates that the contact is normal; If the resistance is very large, it means that the contact contact is poor; If it doesn't, it may be a leak of the thermostat. Whether there is leakage can be first visually inspected, observe whether the sealing welding head of the temperature sensing head is broken, whether the temperature sensing package is damaged and cracked, whether there are bending marks of the temperature sensing tube, etc., and then put the temperature sensing package in warm water of 30-40-C to test whether the contact is closed, if the contact is still not closed. indicates that the thermostat in the temperature sensor package has been leaked; If the contact can be closed, then take out the temperature sensing bag from the water, and the contact is disconnected after being placed in a low temperature environment for a period of time, indicating that the temperature adjustment range of the thermostat is improper, and it can be corrected by the adjusting screw that adjusts the temperature range, turn L in the counterclockwise direction, and try again after 2 hidden I.
Fault Symptom:
After the air conditioner thermostat contacts are sticking due to ignition. The contacts cannot jump open automatically, and the compressor cannot be stopped.
Maintenance method:
Put the temperature sensor bag in the refrigerator (5-lO°C) of the double-door refrigerator, and measure whether the two-wire terminals of the temperature controller are disconnected. If you don't keep opening. Indicates that the contact is adhesive, and the contact can be mechanically forced to break with a flat screwdriver; If the contact can be jumped open, the temperature control range of the thermostat drifts and is low, and the temperature control range adjustment screw can be adjusted clockwise.
Fault Symptom:
Leakage of thermostat.
Maintenance method:
Use a hot towel to heat the thermostat and set the knob to the lowest temperature, and use a multimeter to measure whether the switch of the thermostat is turned on. If the switch doesn't work. This indicates that the thermostat has leaked, and the thermostat should be replaced with a new one.
2. Thermostat for hot and cold air conditioners
The thermostat used in electric air conditioners has two sets of contact mechanisms (cold contacts and hot contacts) in the contact control box, and the same temperature sensing bellows is used to control the heat and cold. Its fault phenomenon and inspection method are basically the same as those of ordinary thermostats, but it should be noted that it should also be checked whether the cold and hot switching actions are sensitive, that is, the compressor circuit should be connected when the refrigeration position is connected, and the electric heater circuit should be connected when the heating position is made.
3. Defrost air conditioner thermostat
The defrost temperature controller is an element installed in the control circuit of a thermal air conditioner specifically for switching the solenoid reversing valve. Its thermostat is placed on the coil of the heat exchanger on the outdoor side. When heating in winter, the frost layer of the outdoor side heat exchanger thickens so that the temperature is lower than a certain set value. Contact action of the defrost controller. Disconnect the solenoid directional valve. The original heating cycle is changed to a cooling cycle. There are two commonly used structural forms: one is the thermal bimetal sheet type: the other is the ordinary thermostat. The method of detection is to place the temperature sensing part in water or air at the corresponding temperature. Use a multimeter to measure whether the two terminals are disconnected or on. You can know the good and the bad. Thermal bimetal thermostats are also used for indoor side cold air control.
4. Temperature sensing resistance
Electronic air-conditioning thermostats or microcomputer-controlled air-conditioners use thermistors as the temperature sensing element. A thermistor is a component whose resistance changes significantly with temperature. Thermistor for ten vertical measurement of return air temperature of air conditioner. It generally has a negative temperature coefficient characteristic: the resistance value decreases with increasing temperature. Specific to the thermistor used in a certain brand of abyss device, its resistance value changes with temperature is generally drawn into a chart in the random manual for testing, and the detection can be in a certain environment. Measurements are made with semiconductor thermometers and multimeters. When the thermistor is aging and the performance drifts, that is, the correspondence between temperature and resistance value changes, a new thermistor sensor should be replaced.
|
More on that
|
RKC Level Gauge – The correct way to use the float level gauge
(1) Before use, first check whether the level gauge is within the verification cycle, otherwise, it should be calibrated, and replaced in time if it is unqualified.
(2) The sensor should be installed horizontally, and the length of the lower entry should meet the technical requirements.
(3) The connection between the sensor and the explosion-proof junction box should be tightened and tightened.
|
|
RKC Level Gauge - the principle of the selection of float level gauges
The float level gauge is widely used, mainly used in petroleum processing, food processing, chemical industry, water treatment, manufacturing, electric power, papermaking, metallurgy, ships and boilers and other industrial automation processes to measure and control the level.
1. Pay attention to the specific working conditions. As introduced ...
|
|
RRKC thermostat wiring installation and some precautions
The rkc controller was developed by Japan and is mainly used in plastics and stoves. Of course, it is also widely used in China's industry, there are many people who do not know much about the rkc controller, and some even feel unfamiliar.
|
|
Key features of the RLC thermostat:
Thermocouples, RTDs, analog and other signals are freely inputted, and the range can be set freely;
The software zeros the full degree, the cold end measures the temperature separately, the amplifier is self-stabilizing, and the display accuracy is better than 0.5%FS;
Fuzzy theory combined with traditional PD method, fast and stable control, advanced tuning ...
|
|
Introduction and wiring method of Japan physical and chemical RKC thermostat
The core control algorithm of the temperature regulator is PID control, P (Proportional) ratio + I (Integral) point + D (Differential) differential control. In addition to the traditional PID control algorithm, RKC also has ON-OFF control, custom parameter control, adaptive parameter control and other algorithms, ...
|
|
RKC thermostat REX-C400 model settings and parameter instructions
Japan RIKA RKC REX-C400 temperature controller product introduction
REX-C400 Digital Thermostat RKC PID Temperature Controller Thermostat (SSR Output) + Type K Thermocouple + *Large 40A SSR Relay
1. Dual display set temperature and process temperature
2. General Digital Programmable Temperature ...
|
|
RKG thermostat – how the temperature controller sets the parameters
1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint.
2. The upper limit deviation alarm is set ...
|
|
RKC converters – what are the functions of converters?
1. Power conversion: convert the voltage (rated 100V) and current (rated 5A or 1A) of the transformer into voltage (several volts) to meet the requirements of weak current components.
2. Isolation: current, secondary side security, and work grounding are used to ensure the safety of people and equipment, while weak current ...
|
|
RK thermostat - classification and precautions for use of central air conditioning thermostat
1. The principle of central air conditioning thermostat
Mechanical thermostats can be divided into vapor pressure thermostats, liquid expansion thermostats, gas adsorption thermostats and metal expansion thermostats. Among them, the vapor pressure thermostat is divided into inflatable type, liquid-gas mixed type and liquid-filled type. Domestic...
|
|
RLC thermostat - a detailed explanation of dry-type transformer thermostats
The working principle of dry-type transformer thermostats
The dry-type transformer temperature controller is a new generation of controller designed for the safe operation of dry-type transformers. The controller adopts single-chip microcomputer technology, and uses three platinum thermal resistors embedded in the three-phase winding of the dry-type transformer to detect and display the transformer.
|
|
RLC thermostat - classification and detailed explanation of floor heating thermostat
1. Mechanical
The sensitive gas diaphragm box or thermal bimetal sheet is used as the temperature sensing element to form the temperature control switch of the mechanical contact. This kind of thermostat is more in the European and American markets, and only a few domestic manufacturers promote such products. Mechanical floor heating thermostats usually have contact currents of no more than 8A, which are suitable for ...
|
|
RKC thermostat REX-C400 model settings and parameter instructions
Japan RIKA RKCREX-C400 temperature controller product introduction.
REX-C400 Digital Temperature Control Controller, RKCPID Temperature Controller, Temperature Controller, (SSR Output) + Type K Thermocouple + *Large 40ASSR Relay.
1. Dual display set temperature and working ...
|
|
How to set the parameters of the RKC rs400 thermostat?
1. Set temperature: Press the SET button to set or check the temperature set point. Press the SET key digital tube character start flashing, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key data will change rapidly, press the SET key again ...
|
|
RKG thermostat - an introduction to the relevant knowledge of temperature controllers
The temperature controller is an electrical switchgear that controls the temperature of an air-conditioned room. The temperature range in the air-conditioned room controlled by the temperature controller is generally 18°C--28°C. The temperature controller commonly used in window air conditioners uses the principle of pressure to push the contacts on and off. Its structure consists of bellows ...
|
|
How to set the parameters of RKC thermostat RH900
1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint.
2. The upper limit deviation alarm is set ...
|
|
RRKC thermostats – the commissioning steps of mechanical thermostats
1. Confirm the angle sample first. See where the angle of the sample is today.
2. Pick up the thermostat, first confirm whether the switch of the thermostat is tight, stuck, whether the white dot falls off, whether there is sound when the thermostat contacts are in contact, and if there is no sound, there should be two possibilities!
...
|
|
RK thermostat - the selection and installation method and precautions of the central air conditioning thermostat
1. Thermostat output control power: The thermostat output control power is the first issue to consider when choosing a thermostat, which is related to the safety and stability of use, and may cause serious consequences if not selected properly, such as: fire. Thermostat products are marked with output control voltage and current, and the ...
|
|
RRKC thermostat – the main function of the thermostat
In most cases, in Europe, the thermostat is a necessary accessory for the wall-hung boiler, and the two are delivered to the user at the same time, and most of the thermostats equipped are intelligent thermostats. In China, nearly 95% of the wall-hung boilers that have been installed in operation and are being installed and debugged and ready to be put into use are not equipped in advance.
|
|
What are the common devices for RKC thermostats – digital displays?
In a variety of electronic control equipment, digital display has become an indispensable and important link. The electronic devices and corresponding driving circuits used for digital display are called digital displays.
Commonly used digital displays include glow digital tube displays, fluorescent digital tube displays, projection ...
|
|
RLC thermostats – the classification of thermostats and their detailed introduction
1. Sudden jump thermostat
The type of various sudden thermostats is collectively called KSD, such as KSD301, KSD302, etc., the thermostat is a new type of bimetal thermostat, mainly as a variety of electric heating products with overheat protection, generally connected with the thermal fuse in series, sudden temperature ...
|
|