Specifications and models of RKC thermostats

Create Date: 2024-8-30 12:03:23|Source: RKC

1. RH400 size: 48*96, depth 60, about 250g

1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L

2. Temperature measurement heat resistance input: PT100, JPT100

3. Tributary voltage: DC0 - DC5V, DC1 - DC5V

Sampling period: 0.5s

Measurement accuracy: Thermocouple: ± (0.3% of displayed value + 1 digit) or ± 2 degrees Temperature measurement resistance: ± (0.3 + 1 digit of displayed value)

(DC0/12V) allowable load resistance above 600 ohms, can be heated and cooled dual output control (output 1: heating side; Output 2: Cooling side)

Optional heater disconnection alarm and control loop disconnection alarm

2. CH402 size: 48*96, depth 100, about 250g

1. Temperature measurement resistance input: PT100, JPT100

2. Tributary voltage: DC0 - DC5V, DC1 - DC5V

3. Tributary current: DC0-20MA, DC4-20MA (250 ohm external resistance required)

Sampling period: 0.5s

Optional heater disconnection alarm and control loop disconnection alarm

Optional 2-wire RS-485 communication

3. CD901 size: 96*96 depth 100, about 340g

1. Temperature measurement resistance input: PT100, JPT100

2. Tributary voltage: DC0 - DC5V, DC1 - DC5V

3. Tributary current: DC0-20MA, DC4-20MA (250 ohm external resistance required)

Multiple alarm types: upper limit input value, lower limit input value, upper limit deviation, lower limit deviation, upper and lower limit deviation, upper and lower range setpoint, lower limit setpoint (standby operation can be attached)

Sampling period: 0.5s

Measurement accuracy: Thermocouple: ± (0.3% of displayed value + 1 digit) or ± 2 degree temperature measurement resistance: ± (0.3% of displayed value + 1 digit) or ± 0.8 degrees tributary voltage/current input: ± (0.3% of displayed value + 1 digit)

(DC0/12V) Allowable load resistance 600, used to drive TRIAC (three-terminal bipolar thyristor) trigger output: Trigger mode - zero cross method, on-current: 50 mA (50 degrees), 70 mA (25 degrees) for zero cross type medium capacity TRIAC (used to drive loads below 100 a) * Heating/cooling type is not possible TRIAC (three-terminal bidirectional thyristor) Output: Rated value 0.5 A (ambient temperature 40 degrees or less)

Optional heater disconnection alarm and control loop disconnection alarm

Optional 2-wire RS-485 communication

4. FB900 size: 96*96*60

Abundant inputs and outputs

Automatic/manual, local/remote direct switching

Multi-area function: Up to 8 different settings can be registered for the master setting, etc., and cumbersome settings can be changed in a lump package. Zones can also be switched via an optional external contact input.

By combining the multi-storage function to connect the number of the other area, the duration of the area, and the setting of the limit of the rate of change, it is possible to run the program up to 16 segments (8 steps).

Frequently used data (up to 16 items) can be freely listed in consecutive addresses, which greatly reduces data transmission and enables high-speed communication.

Joint operation can be carried out using communication

PID control: The sampling cycle can be switched to 0.05s, which corresponds to the high-speed heating process. A new type of heat-and-cool PID that inhibits undershoot on the cooling side. You can switch between the controls of "heating, cooling, heating and cooling, and position ratio".

5. CH102 size: 48*48, depth 100mm about 170g

1. Temperature measurement resistance input: PT100, JPT100

2. Tributary voltage: DC0 - DC5V, DC1 - DC5V

3. Tributary current: DC0-20MA, DC4-20MA (250 ohm external resistance required)

Sampling period: 0.5s

Measurement accuracy: Thermocouple: ± (0.3% of displayed value + 1 digit) or ± 2 degree temperature measurement resistance: ± (0.3% of displayed value + 1 digit) or ± 0.8 tributary voltage/current input: ± (0.3% of displayed value + 1 digit)

Control output: relay contact output: 1c contact (AC250 3A) resistance load voltage pulse output: (DC0/12V) allowable load resistance above 600 ohms current output: (DC4 - 20MA) allowable load resistance above 600 ohms can be heated and cooled dual output control (output 1: heating side; Output 2: Cooling side)

Optional heater disconnection alarm and control loop disconnection alarm

Optional 2-wire RS-485 communication
Specifications and models of RKC thermostats

More on that
Key features of the RLC thermostat: Key features of the RLC thermostat:

Thermocouples, RTDs, analog and other signals are freely inputted, and the range can be set freely; The software zeros the full degree, the cold end measures the temperature separately, the amplifier is self-stabilizing, and the display accuracy is better than 0.5%FS; Fuzzy theory combined with traditional PD method, fast and stable control, advanced tuning ...

RKC Level Gauge – The structure of a float level gauge RKC Level Gauge – The structure of a float level gauge

(1) For the indicator, also known as the display panel, the indicator plays the role of local display, convenient for long-distance observation of the actual situation of the liquid level, the indicator is generally bundled with the pontoon, easy to install. (2) It is a magnetic float, which is located in the pontoon and is in direct contact with the liquid to be measured, ...

RLC Thermostat – The reason why the temperature control meter shows HHH RLC Thermostat – The reason why the temperature control meter shows HHH

The reasons why the temperature control table shows HHH are as follows: 1. The thermocouple signal line is reversed, or short. 2. If the temperature control meter is in normal use before, it is recommended to check whether the signal line of the thermocouple is broken. 3. The wire inside the thermocouple is broken. 4 ...

Wiring method of the RKG thermostat Wiring method of the RKG thermostat

Take CD901 as an example, L(1) pin to 220 volt live wire, N(2) pin 220 volt neutral wire, 3,4 pins for *** output, 5,6 pins for the second output, 7, 8, 9 pins are alarm output, The rear three pins are connected to thermocouples or PT100 and so on.

A few things to note about the installation of the RKC thermostat A few things to note about the installation of the RKC thermostat

1) For RTD input, 3 wires with low resistance and no difference should be used. 2) The input signal line should be far away from the power line of the instrument, the power supply line and the load line to avoid noise and annoyance. 3) The power cord of the instrument is generally annoyed by the power supply. 4) Instrument complement ...

What problems are easy to encounter in the use of RKCPT100 temperature sensor probes? What problems are easy to encounter in the use of RKCPT100 temperature sensor probes?

What problems are easy to encounter in the use of PT100 temperature sensor probes? 1. Is the output signal unstable? A: Maybe it's the temperature instability of the temperature source itself, or the problem of on-site disturbance. 2. Is there a big error in the output of the transmitter? Answer: This ...

Common faults and solutions of intelligent temperature controllers - RTC Common faults and solutions of intelligent temperature controllers - RTC

Master the common problems of several common intelligent temperature controllers, and solve them by yourself when you encounter problems, and you don't need to spend time and effort to find someone to repair, the common problems are as follows: 1. Heating for a period of time, the temperature does not change. Ambient temperature (e.g., room temperature 25°C) is displayed at all times ...

RK thermostat - the performance characteristics of digital display thermostat are introduced RK thermostat - the performance characteristics of digital display thermostat are introduced

1. The special integrated instrument chip has more reliable anti-interference and stability. 2. Signal input, ordinary heat signal can be connected through menu settings. 3. You can modify the display range, transmission output range, alarm value and online report J mode. 4. Soft ...

RRKC thermostat wiring installation and some precautions RRKC thermostat wiring installation and some precautions

The rkc controller was developed by Japan and is mainly used in plastics and stoves. Of course, it is also widely used in China's industry, there are many people who do not know much about the rkc controller, and some even feel unfamiliar.

Introduction to the types of alarms for RKC thermostats Introduction to the types of alarms for RKC thermostats

* Alarm table {ALM1} (standard built-in) A: Upper limit deviation alarm G: Standby upper and lower limit deviation alarm attached B: Lower limit deviation alarm H: Upper limit input value alarm C: Upper and lower limit deviation alarm J: Lower limit input value alarm D: Alarm in the range K: Attached standby ...

What should I pay attention to when operating the RKC thermostat? What should I pay attention to when operating the RKC thermostat?

The instrument can be cleaned only after the power is off; To remove stains from the monitor, use a soft cloth or cotton paper; The display is easy to be scratched, and it is forbidden to use hard objects to operate the panel buttons, otherwise the keys will be damaged or scratched. ...

RRC thermostat - introduction to the working principle and classification of electronic thermostats RRC thermostat - introduction to the working principle and classification of electronic thermostats

Principle of electronic thermostat: The electronic temperature controller (resistive type) is measured by the method of resistance temperature sensing, and generally uses platinum wire, copper wire, tungsten wire and semiconductor (thermistor, etc.) as the temperature measurement resistor, which has its own advantages and disadvantages. Household Air Conditioner Temperature Controller ...

RRKC thermostat - how to set the parameters of the temperature control meter RRKC thermostat - how to set the parameters of the temperature control meter

1. Sensor type (this is based on the actual sensor used) 2. Upper and lower limit range (usually marked on the sensor) 3. Output range setting (current or voltage signal output) 4. Alarm value setting 5. Communication parameter setting (if no point 3 is set, ...)

RKC Thermostats – How to Choose a Thermocouple? RKC Thermostats – How to Choose a Thermocouple?

The selection of thermocouples should be based on comprehensive considerations such as the operating temperature range, the required accuracy, the operating atmosphere, the performance of the measured object, the response time and the economic benefits. 1. Selection of measurement accuracy and temperature measurement range 1) The operating temperature is 1300-1800°C, and the accuracy is required to be more accurate than ...

Steps for the correct adjustment of the thermostat Steps for the correct adjustment of the thermostat

1. First of all, determine the set temperature of the thermostat and make sure that it is the same as the temperature you need. 2. Recognize the operating form of the thermostat, usually there are two forms of cooling and heating, and choose the corresponding form according to the demand. 3. Acknowledging the operating condition of the thermostat, usually with active ...

How to set the parameters of the RCRS400 thermostat How to set the parameters of the RCRS400 thermostat

1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET key digital tube characters to start flashing, indicating that the instrument has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again ...

Precautions for the use of RKC thermostats Precautions for the use of RKC thermostats

fold When the RKC thermostat comes out, it is a single-loop regulator, that is, it only has a heating function, which is called the basic meter, which is generally sent to the agent, and the agent will expand the multi-channel adjustment and alarm output control function, which is called "changing the meter" in the industry, so as to ensure that there is very little hardware cost.

What should I pay attention to when setting up my RKC thermostat? What should I pay attention to when setting up my RKC thermostat?

Wiring Warning: If the instrument fails or an error occurs, which can cause a system failure, an external protection circuit is installed to prevent such accidents: In order to prevent damage or failure of the instrument, choose an appropriate fuse to protect the power cord and input and output lines from strong power shocks. Power supply ...

RKC Level Gauge – How to install a buoy level gauge RKC Level Gauge – How to install a buoy level gauge

1. Welding and installation of the lower support of the guide wire: determine the position at the bottom of the container according to the requirements of the movement direction of the float of the level gauge, and weld or rivet the lower support of the fixed guide wire. If the equipment does not have welding conditions, the heavy anchor fixing method can be used to fix the guide wire under the support. For example, the liquid level wave in the container ...

RRKC thermostat – the correct way to set up the thermostat RRKC thermostat – the correct way to set up the thermostat

Press the SET button to set or view the temperature set point, press the SET key digital tube characters to start flashing, indicating that the instrument has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again The instrument returns to normal working condition ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top