RKG thermostat - an introduction to the characteristics of digital displays

Create Date: 2024-8-30 12:03:23|Source: RKC

1) It is a display of the common cathode. It uses the principle of the positive electrode as the segmented input, with the ground wire as the common output, and the segmented input is valid as a high-level input.

2) It is a display with a common anode. It uses an anode as an aggregate input, and in contrast to the common cathode connection, the segment is effective with a low output.

3) It is an integrated circuit with a display. Use an integrated circuit to package the digital display, regardless of yin and yang, as long as it is used as an integrated circuit.
RKG thermostat - an introduction to the characteristics of digital displays

More on that
Overview of the RLC thermostat Overview of the RLC thermostat

CH and CD series intelligent temperature controller is a multi-functional adjustment instrument with special microprocessing, which adopts switching power supply and surface mount technology (SMT), so the instrument is delicate and compact, and the performance is reliable. The unique self-diagnosis function, self-tuning function and intelligent control function make it possible for the operator to pass the ...

RKC Level Gauge - the principle of the selection of float level gauges RKC Level Gauge - the principle of the selection of float level gauges

The float level gauge is widely used, mainly used in petroleum processing, food processing, chemical industry, water treatment, manufacturing, electric power, papermaking, metallurgy, ships and boilers and other industrial automation processes to measure and control the level. 1. Pay attention to the specific working conditions. As introduced ...

RKC level gauge - the fault and treatment method of float level gauge RKC level gauge - the fault and treatment method of float level gauge

Fault 1, the indication is abnormal The float level gauge is not indicated properly and is a very common fault of the float level gauge. Usually there are the following manifestations: Phenomenon 1: The float level gauge in the atmospheric pressure workshop has the largest indication. Troubleshooting: The float was found to be ...

RLC thermostat - common faults of temperature controllers and solutions RLC thermostat - common faults of temperature controllers and solutions

Fault 1: The device does not display after powering on Solution(s): First of all, check whether the terminals of the device have been connected to the neutral live wire, and make sure that the neutral live power supply can work normally. Then start to check whether the cable between the LCD motherboard and the device drive power supply is ...

RKC Thermostat The structure, action principle and use of some commonly used relays RKC Thermostat The structure, action principle and use of some commonly used relays

  A relay is an electrical appliance that works automatically. When the amount of electricity such as voltage, current, and frequency or non-electricity such as temperature, pressure, and rotational speed is input to the relay, and when the specified value is reached, the contacts of the relay connect or cut off the circuit that controls or protects it. Relays are widely used in motor control and power ...

RDC converters – a classification of power converters RDC converters – a classification of power converters

Motors are divided into two categories: DC motors and AC motors, and AC motors are divided into asynchronous motors and synchronous motors, and their respective speed regulation principles are also different. According to the speed regulation requirements of the motor, it can be divided into two categories: DC power converter and AC power converter: ...

Specifications and models of RKC thermostats Specifications and models of RKC thermostats

1. RH400 size: 48*96, depth 60, about 250g 1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L 2. Temperature measurement heat resistance input: PT100, JPT100 3. Tributary voltage: DC0 - DC5V, DC1 - DC5V ...

Precautions for the use of RKC thermostats Precautions for the use of RKC thermostats

fold When the RKC thermostat comes out, it is a single-loop regulator, that is, it only has a heating function, which is called the basic meter, which is generally sent to the agent, and the agent will expand the multi-channel adjustment and alarm output control function, which is called "changing the meter" in the industry, so as to ensure that there is very little hardware cost.

RRKC Thermostat – Questions and Precautions About Thermostat Expansion Modules RRKC Thermostat – Questions and Precautions About Thermostat Expansion Modules

1. Under what circumstances should I use a thermostat to expand the module? The gradual development of the heating field is now very well recognized, and more and more users have begun to install electric heating, of course, when installing electric heating for users, they have also encountered some headaches. For example, a large area ...

How to set the parameters of RKC thermostat CD901? How to set the parameters of RKC thermostat CD901?

1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

RLC thermostat – the working principle of an electronic temperature controller RLC thermostat – the working principle of an electronic temperature controller

Electronic temperature controller, as the name suggests, is a kind of controller that controls the temperature through electronic circuits, it is mainly used for temperature control of electric heating and plumbing, it is easy to learn in the operation method, and the accuracy of control is also very accurate.

RLC thermostat - a detailed explanation of dry-type transformer thermostats RLC thermostat - a detailed explanation of dry-type transformer thermostats

The working principle of dry-type transformer thermostats The dry-type transformer temperature controller is a new generation of controller designed for the safe operation of dry-type transformers. The controller adopts single-chip microcomputer technology, and uses three platinum thermal resistors embedded in the three-phase winding of the dry-type transformer to detect and display the transformer.

RKC thermostat operation attention and its main features RKC thermostat operation attention and its main features

RKC thermostat operation attention · Clean the instrument only after the power is off; · Please use a soft cloth or cotton paper to remove stains on the monitor; · The display is easy to be scratched, it is forbidden to use hard object to operate the panel buttons, otherwise the keys will be damaged or scratched.   Key features: ...

Introduction and wiring method of Japan physical and chemical RKC thermostat Introduction and wiring method of Japan physical and chemical RKC thermostat

  The core control algorithm of the temperature regulator is PID control, P (Proportional) ratio + I (Integral) point + D (Differential) differential control. In addition to the traditional PID control algorithm, RKC also has ON-OFF control, custom parameter control, adaptive parameter control and other algorithms, ...

RLC Thermostat – How to use a smart temperature controller RLC Thermostat – How to use a smart temperature controller

1. Set temperature: press and hold the SET key, at this time the tube character begins to flash, proving that the instrument has entered the set state, increase the up button, decrease the down button, and press and hold the up and down buttons to quickly change, when the desired temperature is reached, then press the SET button The instrument is set. 2. Return control: press SET ...

RKC Level Gauges – Precautions for Level Gauges RKC Level Gauges – Precautions for Level Gauges

The correct selection of the level gauge can ensure the better use of the level gauge. What kind of level gauge should be selected according to the physical and chemical properties of the fluid medium to be measured? What is the diameter of the level gauge, the flow range, the lining material, the electrode material, and the output current? can adapt to the ...

RLC thermostat - classification and detailed explanation of floor heating thermostat RLC thermostat - classification and detailed explanation of floor heating thermostat

1. Mechanical The sensitive gas diaphragm box or thermal bimetal sheet is used as the temperature sensing element to form the temperature control switch of the mechanical contact. This kind of thermostat is more in the European and American markets, and only a few domestic manufacturers promote such products. Mechanical floor heating thermostats usually have contact currents of no more than 8A, which are suitable for ...

RKC Level Gauge – The correct maintenance method for float level gauges RKC Level Gauge – The correct maintenance method for float level gauges

(1) After 6 months to 1 year of operation, the sensor should be visually inspected and routinely calibrated. (2) Regularly check whether the sensor is bent and deformed by external force to avoid ball jamming. (3) Regularly check whether the magnetic induction switch element of the sensor is aging and failing, ...

RKC Level Gauge – Installation of a pontoon level gauge RKC Level Gauge – Installation of a pontoon level gauge

When transporting and unpacking, it is necessary to avoid excessive shock and vibration; The installation should be firm and reliable, and the pontoon should be installed vertically to prevent the pontoon from colliding with the interior wall of the pontoon; When the pontoon is hooked, it should not swing or pull and compress sharply, so as not to damage the sensor and reduce the accuracy of the instrument; ...

RKG thermostat - an introduction to the relevant knowledge of temperature controllers RKG thermostat - an introduction to the relevant knowledge of temperature controllers

The temperature controller is an electrical switchgear that controls the temperature of an air-conditioned room. The temperature range in the air-conditioned room controlled by the temperature controller is generally 18°C--28°C. The temperature controller commonly used in window air conditioners uses the principle of pressure to push the contacts on and off. Its structure consists of bellows ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top