RHK thermostat - the thermostat shows the reasons for the deviation between the temperature and the actual temperature and the solution

Create Date: 2024-8-30 12:03:23|Source: RKC

The thermostat shows a nonlinear relationship between the temperature and the actual temperature deviation:

(1) The input type of the thermostat is selected incorrectly;

(2) There is no calibration or calibration error in the analog input;

(3) There is interference in the thermostat;

(4) There is interference with thermocouples;

(5) Poor quality temperature sensors are used.

solution

(1) Adjust the zero migration and magnification factor adjustment in the thermostat menu so that the thermostat display is completely consistent with the actual temperature.

(2) The deviation between the temperature displayed by the thermostat and the actual temperature is nonlinear:

a. Set the input type and range of the thermostat correctly;

b. Calibrate the thermostat and set the correct calibration value;

c. The wiring of the thermostat should be kept away from the high-voltage line or the power cable with high current, and avoid being parallel to the power line or making the same wiring. Stand-alone pipes or sheathed shielding are recommended; Separate the thermostat from the device that generates strong high-frequency noise or surge as much as possible, or install a surge suppressor or noise filter on the peripheral equipment that generates noise (especially equipment with inductive elements such as motors, inverters, solenoids, etc.);

d. Generally, the shell type thermocouple is more susceptible to interference, so it is recommended to use an insulated thermocouple;

e. Replace the temperature sensor.
RHK thermostat - the thermostat shows the reasons for the deviation between the temperature and the actual temperature and the solution

More on that
RRKC thermostat - common faults and solutions of stand-alone thermostats RRKC thermostat - common faults and solutions of stand-alone thermostats

Fault 1: The thermostat does not turn on (does not light up) Analyze the causes 1. Wrong wiring 2. The voltage of the input terminal is not enough or the input terminal is damaged by empty opening and leakage 3. Whether the cable between the panel and the power board is broken or plugged incorrectly 4. Load short circuit or open circuit, probe ...

RKC Level Gauges – An introduction to common types of level gauges RKC Level Gauges – An introduction to common types of level gauges

Explosion-proof float level switch Explosion-proof float level switch, also known as explosion-proof float level controller. It is a liquid level control instrument specially designed and manufactured for use in explosive atmospheres, this product is designed based on the principle of buoyancy and the principle of lever, when the liquid level in the container changes, ...

RKC thermostat operation attention and its main features RKC thermostat operation attention and its main features

RKC thermostat operation attention · Clean the instrument only after the power is off; · Please use a soft cloth or cotton paper to remove stains on the monitor; · The display is easy to be scratched, it is forbidden to use hard object to operate the panel buttons, otherwise the keys will be damaged or scratched.   Key features: ...

RLC thermostat – how to install the thermostat RLC thermostat – how to install the thermostat

1. In which room should the thermostat be installed? It is very important to choose a reasonable location to install the thermostat, which will directly affect the work of the wall-hung furnace in your home, the main living room (living room) should be your best choice, you can also install the thermostat in the bedroom according to your personal needs.

Specifications and models of RKC thermostats Specifications and models of RKC thermostats

1. RH400 size: 48*96, depth 60, about 250g 1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L 2. Temperature measurement heat resistance input: PT100, JPT100 3. Tributary voltage: DC0 - DC5V, DC1 - DC5V ...

How to set the parameters of RKC thermostat RH900 How to set the parameters of RKC thermostat RH900

1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

Parameter setting operation of RLC temperature control table CH402 Parameter setting operation of RLC temperature control table CH402

Model: CH402FS01-8*HN (for PECVD temperature control) 1) Single press SET: SV can be set (set temperature manually) 2) Press and hold the SET button for 2 seconds, ALI=1000 (absolute alarm temperature setting) and then press the SET button, ATU=1 (self-defining, self-interpreting a set of PID parameters) to exit ...

RRC thermostat - the principle of sudden jump thermostat, how to judge the good or bad? RRC thermostat - the principle of sudden jump thermostat, how to judge the good or bad?

1. What is the principle of the sudden jump thermostat? The sudden jump thermostat is a kind of thermostat, which is a series of automatic control elements that are physically deformed inside the switch according to the temperature change of the working environment, resulting in some special effects and on-off action. Sudden jump ...

RLC thermostat - common faults and treatment methods of dry-type transformer thermostats RLC thermostat - common faults and treatment methods of dry-type transformer thermostats

1. There is no display of dry-type transformer thermostat Cause of failure: (1) The power supply of the thermostat is not connected; (2) The fuse is blown out. Solution: (1) Turn on the power supply; (2) Replace the fuse. 2. The dry-type transformer thermostat shows that one or three phases are flashing and displays "-OP-" ...

RK thermostat - the problem that should be paid attention to in the installation of floor heating thermostat RK thermostat - the problem that should be paid attention to in the installation of floor heating thermostat

1. Wall installation, the height is about 1.2 meters, generally on the same horizontal line as the electric lighting switch of the home. 2. Installed on a wall where the surrounding air flows freely, and is not affected by other heat sources (e.g. sunlight), air flow from doors and windows, or external wall temperature, etc. 3. Advance ...

How to set the parameters of the RCRS400 thermostat How to set the parameters of the RCRS400 thermostat

1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET key digital tube characters to start flashing, indicating that the instrument has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again ...

How to set the parameters of the RKC rs400 thermostat? How to set the parameters of the RKC rs400 thermostat?

1. Set temperature: Press the SET button to set or check the temperature set point. Press the SET key digital tube character start flashing, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key data will change rapidly, press the SET key again ...

RLC Thermostat – How to use a smart temperature controller RLC Thermostat – How to use a smart temperature controller

1. Set temperature: press and hold the SET key, at this time the tube character begins to flash, proving that the instrument has entered the set state, increase the up button, decrease the down button, and press and hold the up and down buttons to quickly change, when the desired temperature is reached, then press the SET button The instrument is set. 2. Return control: press SET ...

RKC level gauge - buoy level gauge structure composition RKC level gauge - buoy level gauge structure composition

The level gauge is composed of five parts: float, traction cable, guide pulley, hammer pointer, display ruler or magnetic flap. 1. Float: The float is welded with two stainless steel (or carbon steel) fasting cones and one stainless steel (or carbon steel) fasting cylinder.

RRKC thermostat - five common faults and solutions of smart thermostats RRKC thermostat - five common faults and solutions of smart thermostats

After heating for a while, the temperature does not change. Displays the ambient temperature of the site at all times (e.g. room temperature 25°C) In case of such a fault, first check whether the SV value setting value is set, whether the OUT indicator of the meter is lit, and whether the No. 3 and No. 4 terminals of the meter are 12VDC output with the "multimeter". ...

RK thermostat - classification and precautions for use of central air conditioning thermostat RK thermostat - classification and precautions for use of central air conditioning thermostat

1. The principle of central air conditioning thermostat Mechanical thermostats can be divided into vapor pressure thermostats, liquid expansion thermostats, gas adsorption thermostats and metal expansion thermostats. Among them, the vapor pressure thermostat is divided into inflatable type, liquid-gas mixed type and liquid-filled type. Domestic...

What are the common devices for RKC thermostats – digital displays? What are the common devices for RKC thermostats – digital displays?

In a variety of electronic control equipment, digital display has become an indispensable and important link. The electronic devices and corresponding driving circuits used for digital display are called digital displays. Commonly used digital displays include glow digital tube displays, fluorescent digital tube displays, projection ...

Wiring method of the RKG thermostat Wiring method of the RKG thermostat

Take CD901 as an example, L(1) pin to 220 volt live wire, N(2) pin 220 volt neutral wire, 3,4 pins for *** output, 5,6 pins for the second output, 7, 8, 9 pins are alarm output, The rear three pins are connected to thermocouples or PT100 and so on.

Wiring method of the RKG thermostat Wiring method of the RKG thermostat

Take CD901 as an example, L(1) pin to 220 volt live wire, N(2) pin 220 volt neutral wire, 3,4 pins for the first output, 5,6 pins for the second output, 7, 8, 9 pins are alarm output, Finally, the three pins are connected to thermocouples or PT100 ...

RRKC thermostat - how to set the parameters of the temperature control meter RRKC thermostat - how to set the parameters of the temperature control meter

1. Sensor type (this is based on the actual sensor used) 2. Upper and lower limit range (usually marked on the sensor) 3. Output range setting (current or voltage signal output) 4. Alarm value setting 5. Communication parameter setting (if no point 3 is set, ...)

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top