RKC Level Gauge – Some installation requirements for pontoon level gauges

Create Date: 2024-8-30 12:03:23|Source: RKC

1. The installation of the level gauge must be vertical to ensure that the inner pontoon can move up and down freely in the pipe body.

2. Install a shut-off valve between the container and the liquid level gauge to clean and overhaul the liquid level timing to cut off the material.

3. No magnets are allowed to approach around the main body of the float level gauge, otherwise it will directly affect the normal operation of the level gauge.

4. After the installation of the liquid level gauge, the magnet is required to calibrate, and the red is displayed below the zero position and white above the zero position for the guidance of the turning column.

5. When the liquid level gauge is put into operation, the valve of the lower drain should be opened first to let the liquid medium enter the main pipe smoothly, so as to avoid the liquid medium from rising rapidly while staying in the float assembly, resulting in the failure of the flip column and the random overturn. (If this phenomenon occurs, it can be re-calibrated with magnets after the liquid level is stable)

6. In order to prevent the float assembly from being damaged during transportation, take out the inner pontoon out of the float level gauge before leaving the factory. After the level gauge is installed, open the bottom blowdown flange, and then reload the float into the pipe, note that the heavy end of the float is facing upwards and cannot be reversed.
RKC Level Gauge – Some installation requirements for pontoon level gauges

More on that
Physical and chemical RKC thermostat - dry-type transformer thermostat displays fault handling methods Physical and chemical RKC thermostat - dry-type transformer thermostat displays fault handling methods

1. The dry-type transformer thermostat is not visible Causes of failure: (1) The power supply of the thermostat is not connected; (2) Fuse fuse. Handling method: (1) Turn on the power supply; (2) Replace the fuse. 2. The dry-type transformer thermostat shows a certain phase or three phases shining and shows "-OP-" ...

RKC thermostat - classification introduction of displays RKC thermostat - classification introduction of displays

(1) Classification according to display color 1. Monochrome display This monitor has two types: grayscale monochrome display and VGA multi-frequency monochrome display. These displays are small, lightweight, clear and inexpensive, and are suitable for highly mobile workplaces. 2. Color ...

RKC thermostat - overview and characteristics of mechanical thermostat RKC thermostat - overview and characteristics of mechanical thermostat

Mechanical thermostats are suitable for indoor temperature control in industrial, commercial and civil buildings. The mechanical thermostat uses an inflatable membrane box to sense the temperature and compare it with the user's set temperature, and automatically controls the air conditioning equipment to achieve the purpose of indoor temperature constant. Used in commercial, industrial and civil buildings, it can be used ...

RKC thermostat - what are the technical parameters of the jump thermostat? RKC thermostat - what are the technical parameters of the jump thermostat?

1. Electrical parameters: (1) VDE, CQC, UL, TüVAC250V 50-60Hz 10A (resistive load) (2) ULAC125V 50Hz 15A (resistive load) 2. Operating temperature range: -50-270°C (optional), temperature accuracy: ≥ ±2°C 3. Reset and action ...

RKC Level Gauge – How to properly install a float level gauge RKC Level Gauge – How to properly install a float level gauge

In general, when installing a float level meter, the following points should be followed: 1. In order to prevent the float from sliding or hitting the sealing tube at high speed during transportation, causing the measuring belt to come out, the instrument fixes the float at the bottom of the sealing tube with clamps before leaving the factory, and the magnet is placed on the top of the sealing tube.

Parameter setting operation of RKC temperature control meter CH402 Parameter setting operation of RKC temperature control meter CH402

Model: CH402FS01-8*HN (for PECVD temperature control) 1) Single press SET: SV can be set (manual temperature set) 2) Press and hold the SET button for 2 seconds, ALI=1000 (absolute alarm temperature setting) and then press the SET key, ATU=1 (self-determination, self-rehearsal of a set of PID parameters) to exit...

RKC thermostat – installation and use instructions for jump thermostats RKC thermostat – installation and use instructions for jump thermostats

1. Grounding method: connected to the grounding metal parts of the equipment through the metal cover of the thermostat. 2. The thermostat should work in a general indoor environment where the relative humidity of the air is not greater than 90%, and there is no corrosive gas, flammable gas and conductive dust. 3. The thermostat adopts contact ...

Common faults in the use of RKC thermostat Pt100 thermal resistors Common faults in the use of RKC thermostat Pt100 thermal resistors

  PT100 thermal resistor is a platinum thermal resistor, which can be regarded as a commonly used thermometer in the range of medium and low temperatures, and its range of use is very wide, including medical, electrothermal, industrial production, thermometers and other high-precision thermometers. But due to the range of use ...

RKC Level Gauge - Buoy Level Gauge Use and Precautions RKC Level Gauge - Buoy Level Gauge Use and Precautions

1. Guide wire lower support welding: According to the direction of movement of the level gauge buoy, determine the position at the bottom of the container, weld or rivet the guide bracket under the steel wire (piece 1) 2. Install the guide rail joint. (1) Straighten the steel wire hard and fix it at the lower support, paying attention to ...

RKC thermostat - what should be paid attention to when maintaining the temperature controller RKC thermostat - what should be paid attention to when maintaining the temperature controller

1. Do not wipe with acidic, alkaline and other corrosive liquids and water-containing rags when cleaning, so as not to damage the temperature controller and affect its normal use. 2. Do not decorate and cover the temperature controller. The thermostat has a built-in temperature sensor to sense the outside temperature. Therefore, Wen ...

RKC thermostat - common faults and treatment methods of dry-type transformer thermostats RKC thermostat - common faults and treatment methods of dry-type transformer thermostats

1. The dry-type transformer thermostat is not displayed Causes of failure: (1) The power supply of the thermostat is not connected; (2) Fuse fuse. Treatment method: (1) Turn on the power supply; (2) Replace the fuse. 2. The dry-type transformer thermostat shows that a certain phase or three phases are flashing and displays "-OP-" ...

RKC Transformer - Control strategy for the transformer RKC Transformer - Control strategy for the transformer

Direct transformation method The direct transformation method is to synthesize the "output voltage" through the continuous chopping of the input voltage, which can be divided into coordinate transformation method, harmonic injection method, equivalent conductance method and scalar method, although all these methods have certain advantages, but there are also certain problems, ...

How the thermostat works – RKC How the thermostat works – RKC

Thermostat, according to the temperature change of the working environment, the physical deformation occurs inside the switch, resulting in certain special effects, producing a series of automatic control elements that turn on or off the action, or the electronic components under different temperatures, different principles of working state to give ...

RK thermostat - common problems and solutions of electric floor heating stand-alone thermostat RK thermostat - common problems and solutions of electric floor heating stand-alone thermostat

Fault 1: The thermostat does not turn on (the screen does not display) Analyze the causes 1. Wrong wiring; 2. The voltage of the input terminal is not enough or the input terminal is damaged by the empty leakage guarantee; 3. Whether the cable between the panel and the power board is broken or plugged incorrectly; 4. Load short circuit or broken ...

What problems are RKCPT100 temperature sensor probes prone to encounter in use? What problems are RKCPT100 temperature sensor probes prone to encounter in use?

What problems are PT100 temperature sensor probes more likely to encounter during use? 1. The output signal is unstable? Answer: It may be the temperature of the temperature source itself, or the problem of on-site disturbance. 2. The output error of the transmitter is large? Answer: This kind of ...

RKCRS400 thermostat parameter setting method RKCRS400 thermostat parameter setting method

1. Set temperature: press the SET button to set or view the temperature set point. Press the SET key to start flashing, indicating that the instrument has entered the setting state, press the △ key setting value to increase, press the ▽ key to decrease, long press the △ key or ▽ key to change the data will change rapidly, press the SET key again ...

RKC thermostat - the principle of the jump thermostat, how to judge whether it is good or bad? RKC thermostat - the principle of the jump thermostat, how to judge whether it is good or bad?

1. What is the principle of the jump thermostat? The jump thermostat is a kind of thermostat, which is physically deformed inside the switch according to the temperature change of the working environment, resulting in some special effects and a series of automatic control elements that turn on or disconnect. Jump ...

RRKC thermostats – the commissioning steps of mechanical thermostats RRKC thermostats – the commissioning steps of mechanical thermostats

1. Confirm the angle sample first. See where the angle of the sample is today. 2. Pick up the thermostat, first confirm whether the switch of the thermostat is tight, stuck, whether the white dot falls off, whether there is sound when the thermostat contacts are in contact, and if there is no sound, there should be two possibilities! ...

RKC product model introduction RKC product model introduction

RKC Recommended Product Models: Single-phase power regulator THV-10(20A, 30A, 45A, 60A, 80A, 100A)   Ethernet communication converter COM-ME series   USB communication converter COM-KG   Digital Display Controller (Process/Temperature...

RKC thermostat - the thermostat shows the cause of the deviation between the temperature and the actual temperature and the solution RKC thermostat - the thermostat shows the cause of the deviation between the temperature and the actual temperature and the solution

The thermostat shows that the temperature and actual temperature deviations are nonlinear: (1) The input type of the thermostat is selected incorrectly; (2) There is no calibration or calibration error in the analog input; (3) There is interference in the thermostat; (4) There is interference in thermocouples; (5) The quality of the use is not ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top