RRKC thermostat wiring installation and some precautions

Create Date: 2024-8-30 12:03:23|Source: RKC

The rkc controller was developed by Japan and is mainly used in plastics and stoves. Of course, it is also widely used in China's industry, there are many people who don't know much about the rkc controller, and some even feel unfamiliar, let's take a look at the rkc thermostat together, find its uniqueness, taste its unique charm, and let you have a new understanding. At the same time, it also briefly introduces its wiring, installation, control methods and some precautions, so that you can easily control and deal with the things around you. Here's an introduction to all aspects, so check it out.

Uniqueness

fold

When the RKC thermostat comes out, it is a single-loop regulator, that is, there is only a heating function, which is called the basic table, which is generally sent to the agent, and the agent will expand the multi-channel adjustment and alarm output control function, which is called "changing the table" in the industry, which ensures that the multi-function expansion can be achieved with little hardware cost, which is a function that other thermostats do not have, in addition, the input range and alarm range of the RKC thermostat can be set by # software and parameters, which is more convenient, The overcurrent protection function can be realized by the impressed current transformer, with 485 communication port, which can communicate with the host computer.

Control method folding

The control method of RKC temperature control meter is divided into two modes of heating and cooling, cooling is divided into air cooling and water cooling, the single-loop heating mode is mostly used on general industrial equipment, the heating method has heating wire and steam heating, heating wire heating is relatively simple, it is realized by the heating mode of resistance, and the steam heating mode is realized by adjusting the valve of the RKC thermostat to achieve the control of steam volume.

Precautions folding

a. The instrument is installed in the following environment:

Overvoltage class II

Pollution level 2

. Avoid the following when installing:

The ambient temperature is below 0°C or above 50°C

Ambient humidity is less than 45% or greater than 85% RH

Sudden changes in ambient temperature can cause condensation

Corrosive, flammable gases

Direct vibration or impact of the main structure

Water, oil, chemical, smoke or vapor contamination

Excessive dust, salt, or metal powders

Excessive noise, static electricity, magnetic fields, or noise

Direct blowing of air conditioning

When used indoors, do not place in direct sunlight

Where heat radiation accumulates

Install the fold

(1) According to the size of the opening on the disc surface, a rectangular square hole for installing the instrument is punched on the disc surface.

(2) Embed the instrument into the opening of the panel

(3) Insert the mounting bracket into the instrument mounting slot.

(4) Push the mounting bracket to make the instrument and the panel firmly combined, and then tighten the screws with a screwdriver, but to prevent overtightening.

(5) Use screws to also set the instrument on the disk surface, insert the mounting bracket into the instrument and then use two screws to fix the instrument on the disk surface, when tightening the screws, when the screws touch the disk surface, you can tighten it again, please use the attached screws.

The wiring is folded

Take CD901 as an example,

L(1) pin to 220 volt live wire,

N(2) pin 220 volt neutral wire,

3,4 pins for the first output,

5,6 pins for the second output,

7, 8, 9 pins are alarm output,

The last three pins are connected to the thermocouple or PT100 temperature sensor signal [1]

Control method folding

The control method is divided into two modes of heating and cooling, and the cooling is divided into air cooling and water cooling, and the single-loop heating mode is mostly used on general industrial equipment, and the heating method has heating wire and steam heating, the heating wire heating is relatively simple, which is realized by the heating mode of resistance, and the steam heating mode is to realize the control of steam volume by adjusting the valve of the RKC thermostat.
RRKC thermostat wiring installation and some precautions

More on that
RLC Level Gauge - Classification and construction of pontoon level gauges RLC Level Gauge - Classification and construction of pontoon level gauges

1. Classification of pontoon level gauges The pontoon level gauge is also divided into two types: inner pontoon and outer pontoon, the so-called internal and external division refers to the place where the pontoon is installed, in the container of the liquid to be measured is the inner pontoon, and the outer pontoon is called the outer pontoon outside the liquid container to be measured.

What should I pay attention to when wiring the RKG thermostat? What should I pay attention to when wiring the RKG thermostat?

1. For thermocouple input, the corresponding compensation wire should be used. 2. For RTD input, 3 wires with low resistance and no difference should be used 3. The input signal line should be far away from the power line of the instrument. Power supply and load lines to avoid noise interference 4. The instrument power cord is usually ...

Parameter setting operation of RLC temperature control table CH402 Parameter setting operation of RLC temperature control table CH402

Model: CH402FS01-8*HN (for PECVD temperature control) 1) Single press SET: SV can be set (set temperature manually) 2) Press and hold the SET button for 2 seconds, ALI=1000 (absolute alarm temperature setting) and then press the SET button, ATU=1 (self-defining, self-interpreting a set of PID parameters) to exit ...

RHK thermostat – a rapid detection method for common air conditioner thermostats RHK thermostat – a rapid detection method for common air conditioner thermostats

1 Bellows or diaphragm air conditioner thermostat Fault Symptom: Poor contact or burning, resulting in the circuit cannot be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; Leakage of thermostat in the temperature sensing chamber, causing the contacts to fail to operate and lose control ...

What are the technical parameters of the rkc thermostat - the jump thermostat? What are the technical parameters of the rkc thermostat - the jump thermostat?

1. Electrical parameters: (1) VDE, CQC, UL, TüVAC250V 50-60Hz 10A (resistive load) (2) ULAC125V 50Hz 15A (resistive load) 2. Operating temperature range: -50-270°C (optional), temperature accuracy: ≥ ±2°C 3. Reset and action ...

RLC Thermostat - Introduction to the function of mechanical temperature control RLC Thermostat - Introduction to the function of mechanical temperature control

1. The temperature setting is set by the knob, which is convenient and intuitive 2. It can be directly installed on the standard junction box on the wall. 3. Beautiful appearance and reliable performance. 4. The switch adopts toggle type, which feels comfortable and has a long life. 5. It can control two-wire or three-wire electric (ball...

Initialization parameter setting of the rkc thermostat Initialization parameter setting of the rkc thermostat

1. Press the ISET) button for 2 seconds to enter the parameter setting mode, press ISET until "LCK" is displayed, press the [] key to move the cursor to the thousands, and press the [] button to change the number of thousands from "0" to "1" to display "1000" to unlock. 2. Press the ISET button for 3 seconds to return to SV/PV display mode 3. Press [SET]+ ...

RKC Level Gauges – How to Install Float Level Gauges Correctly RKC Level Gauges – How to Install Float Level Gauges Correctly

In general, the following points should be followed when installing a float level timer: 1. In order to prevent the float from sliding or hitting the sealed tube at high speed during transportation, causing the measuring belt to fall out, the instrument is fixed at the bottom of the sealed tube with a clamp before leaving the factory, and the magnet is on the top of the sealed tube.

RK Thermostat - Part of the LCD shows the status quo of floor heating thermostats RK Thermostat - Part of the LCD shows the status quo of floor heating thermostats

1) The LCD interface is too large or the display symbols are not proportional or standard. 2) The terminal blocks or circuits (components) that control the output cannot withstand large currents. 3) The cable of the external sensor (ground probe) is a thin and flexible wire, which cannot be inserted into the embedded pipe, and it is also a hidden danger for future maintenance. ...

RRKC Thermostats – Considerations for Instrumentation Maintenance and Maintenance RRKC Thermostats – Considerations for Instrumentation Maintenance and Maintenance

There are many types of instrumentation and have a wide range of applications in many fields. Because of this, there are many problems with the failure of instruments in the process of use, so it is necessary to pay more attention to the repair and maintenance of instruments and meters, which can effectively improve the performance of instruments and meters, and can extend the performance of instruments and meters.

The main technical indicators of RKC thermostat The main technical indicators of RKC thermostat

The main technical indicators of RKC thermostat · Input: various thermocouple (TC), RTD standard current and voltage signals (see input type table); · basic error: 0.5% of the input full-scale ±±1 word; · Resolution: 1°C, 0.1°C; ...

A few things to note about the installation of the RKC thermostat A few things to note about the installation of the RKC thermostat

1) For RTD input, 3 wires with low resistance and no difference should be used. 2) The input signal line should be far away from the power line of the instrument, the power supply line and the load line to avoid noise and annoyance. 3) The power cord of the instrument is generally annoyed by the power supply. 4) Instrument complement ...

RLC thermostat – the wiring method of the thermostat RLC thermostat – the wiring method of the thermostat

Many household appliances and large-scale equipment products will be installed in the use of thermostats, thermostats will be combined with the change of ambient temperature in the switch when working physical deformation, which will produce some special effects, resulting in conduction or disconnection action, in order to achieve automatic ...

RKC thermostat - how to prevent freezing and heat preservation of instruments in winter? RKC thermostat - how to prevent freezing and heat preservation of instruments in winter?

In winter, the surface of the power plant's measuring instruments is frozen and condensed, which can lead to poisoning, fire and even explosion. Therefore, the cold and freeze protection of the appearance of the instrument is particularly important. First, the selection method (1) Choose the appearance with insulation device. According to the category of appearance ...

RKC thermostat - what should be paid attention to when maintaining the thermostat? RKC thermostat - what should be paid attention to when maintaining the thermostat?

1. Do not wipe with acidic, alkaline and other corrosive liquids and water-containing rags when cleaning, so as not to damage the temperature controller and affect its normal use. 2. Do not decorate and cover the temperature controller. The thermostat has a built-in temperature sensor to sense the outside temperature. Therefore, Wen ...

RKG thermostat - an introduction to the characteristics of digital displays RKG thermostat - an introduction to the characteristics of digital displays

1) It is a display of the common cathode. It uses the principle of the positive electrode as the segmented input, with the ground wire as the common output, and the segmented input is valid as a high-level input. 2) It is a display with a common anode. It uses an anode as an aggregate input, and in contrast to the common cathode, the segment is effective at a low level output ...

RLC thermostat – what you should pay attention to when maintaining your temperature controller RLC thermostat – what you should pay attention to when maintaining your temperature controller

1. Do not wipe with acidic, alkaline and other corrosive liquids and water-containing rags when cleaning, so as not to damage the temperature controller and affect its normal use. 2. Do not decorate and cover the temperature controller. The thermostat has a built-in temperature sensor to sense the outside temperature. Therefore, Wen ...

RLC thermostats – a common failure of mechanical thermostats RLC thermostats – a common failure of mechanical thermostats

1. The terminal post of the thermostat is stuck and falls off Cause the compressor not to start, the thermostat dynamic and static contacts can not be disconnected, so that the compressor does not run, the thermostat contacts can not be disconnected, so that the motor of the refrigerator compressor does not stop, in addition to the balance elastic force is too weak, it can also be ...

How to set the parameters of RKC thermostat RH900 How to set the parameters of RKC thermostat RH900

1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

RLC thermostats – the classification of thermostats and their detailed introduction RLC thermostats – the classification of thermostats and their detailed introduction

1. Sudden jump thermostat The type of various sudden thermostats is collectively called KSD, such as KSD301, KSD302, etc., the thermostat is a new type of bimetal thermostat, mainly as a variety of electric heating products with overheat protection, generally connected with the thermal fuse in series, sudden temperature ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top