Advantages of Yaskawa inverter A1000

Create Date: 2024-8-30 12:03:23|Source: YASKAWA/Yaskawa

Excellent motor drive function

  Advanced motor drive skills

All motors can be controlled – whether they are driving induction motors or synchronous motors (IPM motors/SPM motors) – with high utility current vectoring.

Inverters for induction motors and synchronous motors can be used universally

It is possible to switch between induction motor and synchronous motor after parameter setting

  Equipped with a wealth of self-learning functions

Built-in a variety of self-learning methods, whether it is driving an induction motor or a synchronous motor, it can give full play to the driving function

The self-learning content also includes the customer's machinery

Online self-learning equipped with new methods

  Instantaneous power outage measures that fit the purpose

Two types of instantaneous power failure compensation functions can be selected

It can be used for sensorless operation of induction motors or synchronous motors

Instantaneous power failure compensation of 2 seconds* is possible

  It starts with the environmental performance of the drive

  energy conservation

  Advanced motor drive skills

The energy-saving operation of the inverter can be used to complete the high-efficiency operation of the induction motor.

  More energy efficient when used in synchronous motors

The simultaneous use of high-efficiency synchronous motors and energy-saving control of inverters can further improve the energy-saving effect compared to induction motors.

  Environmental resistance

  Environmental resistance planning

We also have reinforced products that are resistant to moisture, dust, oil, vibration, and other environments

We also have a maintenance structure such as dustproof and drip-proof IP54 ∗

RoHS compliant

The regulated products comply with the RoHS (European Restriction on the Use of Specified Hazardous Substances) directive

  Noise reduction

The Swing PWM method reduces the screeching noise while suppressing the electromagnetic disturbance

  Press the higher harmonics of the power supply

DC reactor for higher harmonic pressing (22 kW or more) as standard

12-phase and 18-phase rectifier options are available∗ and higher harmonic filters are available

  Safe environment

  Comply with safety regulations

Compliant with EN954-1 Cat.3 and IEC/EN61508 SIL2

The EDM (External Device Monitor) function has been added to supervise the operation of safety functions

  Safe abort in the event of a power outage

Equipped with the Kinetic Energy Back-up (KEB) function, which allows the motor to be quickly and safely decelerated and stopped without running freely in the event of a power failure

  Industry-leading function for changing mechanical grades

  Accelerate compact planning for machine miniaturization

The combination of a miniaturized inverter and a compact, lightweight synchronous motor accelerates the process of machine miniaturization

After the side-by-side device, the size of the device can be further reduced

A heatsink type is available

Two layers of additional functions make the machine more miniaturized

  Customize the drive to your liking Equipped with the visual programming function DriveWorksEZ ∗

Using a computer, through the drag-and-drop operation of the mouse, it can be easily according to the customer's mechanical specifications

Customized drives. Special actions and new detection functions can be programmed and loaded into the inverter.

  Easy commissioning

Proactively set the appropriate parameters

Environmental resistance

  Equipped with a USB port for easy connection to a computer

Connect with your computer via the USB port

  Really reliable braking function

Using the excitation braking function, it can also be used for emergency braking without braking resistance

The model with a built-in braking transistor has been expanded, and a braking resistor can be increased to achieve greater braking power

  Longevity number planning

Planned life of the inverter: 10 years

Motor life - synchronous motors have no copper loss of rotor and low bearing temperature, so the life of motor bearings is about 2 times that of induction motors

Reminder signal output for diagnosis and prediction of life expectancy
Advantages of Yaskawa inverter A1000




More on that
How to set the parameters of Yaskawa H1000 inverter multi-stage speed? How to set the parameters of Yaskawa H1000 inverter multi-stage speed?

Yaskawa H1000 inverter parameter model setting steps: Yaskawa H1000 hoisting using debugging steps (with PG ) No. Name Optimal value A 1-02 Control Mode Selection 3: With PG Vector Control A 1-03 Initialization 2220: 2 Wire Initialization A ...

Yaskawa inverter - what are the common measures for anti-interference of high-voltage inverter? Yaskawa inverter - what are the common measures for anti-interference of high-voltage inverter?

(1) The E end of the high-voltage inverter should be connected to the shell of the control cabinet and the motor, and should be connected to the ground, and the grounding resistance should be less than 100Ω, which can absorb surge interference. (2) The input or output of the high-voltage inverter is equipped with an inductive magnetic ring filter. Flat and 3-4 turns, helps to inhibit ...

Common types of Yaskawa drives Common types of Yaskawa drives

H1000 The new Yaskawa "H1000" heavy-duty inverter plays a stable and outstanding role in the heavy-duty industrial field! Capacity range 200V class 0.4-110kW 400V class 0.4 - 355kW apply Lifting Machinery, Fluid Machinery, Metalworking Machines ...

Causes and solutions of Yaskawa servo drive fault code R10 Causes and solutions of Yaskawa servo drive fault code R10

1. The acceleration/deceleration time constant is too small. Increase the acceleration/deceleration time constant. 2. The torque limit value set by the controller is too small. Increase the torque limit value. 3. The motor cannot start due to the insufficient torque caused by the drop in power supply voltage. 4. Check the power capacity. ...

Yaskawa Robotics - Top 10 Trends in the Industrial Robot Automation Industry Yaskawa Robotics - Top 10 Trends in the Industrial Robot Automation Industry

1. The demand for smart sensors is increasing Quality inspection is a key component in all industries. Analyzing everything from food to phone covers ensures that consumers can trust the goods they receive. Smart sensors enable manufacturers to more efficiently handle this ...

Yaskawa MOTOMAN servo drive fault repair case summary (3-4) Yaskawa MOTOMAN servo drive fault repair case summary (3-4)

3. When the oscilloscope checks the current monitoring output of the driver, it is found that it is all noise and cannot be read; Cause of failure: The current monitoring output is not isolated from the AC power supply (transformer). Solution: It can be detected and observed with a DC voltmeter. 4、LE ...

Yaskawa inverter - what are the control methods of low-voltage inverter? Yaskawa inverter - what are the control methods of low-voltage inverter?

1. Sinusoidal pulse width modulation Sinusoidal Pulse Width Modulation (SPWM) is characterized by simple structure of control circuit, low cost, good hardness of mechanical characteristics, and can meet the smooth speed regulation requirements of general transmission, and has been widely used in various fields of the industry. However, this control ...

Common faults of Yaskawa inverters Common faults of Yaskawa inverters

The switching power supply is damaged Switching power supply damage is the most common fault of many inverters, usually caused by short circuit in the load of switching power supply, in the design of switching power supply circuits of many inverters, Yaskawa inverter is relatively successful. OH failure Old...

Yaskawa servo drive parameters Yaskawa servo drive parameters

PN000 function selection N.0010 (setting value) 0th position: set the direction of rotation of the motor; Set "1" to change the rotation of the motor in reverse. 1st position: Set the control mode to: "1" position control mode. PN200 Command Pulse Input Mode Function Selection N.0101 (Set Value) "1" Positive ...

Yaskawa servo alarm C90 (AC9) troubleshooting method Yaskawa servo alarm C90 (AC9) troubleshooting method

1. Analysis of the causes of Yaskawa servo alarm C90 (AC9): 1. The encoder cable is broken or the encoder plug is made in poor process (there are also wiring errors in the alarm of the new machine); 2. The servo drive itself is faulty; 3. Environmental interference, caused by poor connection: ...

What is the difference between the origin setting of Yaskawa robot, the location of the second origin, and the location of the origin of the job? What is the difference between the origin setting of Yaskawa robot, the location of the second origin, and the location of the origin of the job?

What is the difference between the origin setting of Yaskawa robot, the location of the second origin, and the location of the origin of the job? Origin Setting: Lets you set the origin and initial position of each axis. The robot → the origin position → point display, and select the axis and robot you want to set 1. Write origin data → point ...

A brief introduction to Yaskawa inverter V1000 A brief introduction to Yaskawa inverter V1000

Yaskawa inverter V1000 series has amazing performance, wide range of uses, simple use and maintenance, and user-programmed function, breaking through the previous small inverter in every aspect and improving the level of all small machines. 1 multi-purpose (synchronous motor can also be driven). Detergent ...

ATI+Yaskawa work together to achieve force-controlled weld grinding of complex workpieces ATI+Yaskawa work together to achieve force-controlled weld grinding of complex workpieces

As we all know, the traditional material removal work is done manually, the cost is high, the efficiency is low, the accuracy of the parts is greatly affected by the manual, and the safety of workers is not effectively guaranteed, so what can be done to effectively solve these problems? Today, I will take you to understand the machine ...

Replacement of Yaskawa inverter spare parts Replacement of Yaskawa inverter spare parts

The inverter is composed of a variety of components, some of which will gradually decline and age after the temporary task, which is also an important cause of the failure of the inverter, in order to ensure the temporary normal operation of the equipment, the following devices should be replaced on a regular basis: 2.1 Cooling fan Frequency converters ...

Summary of Common Faults and Solutions of Yaskawa Robots and Accessories (9-17) Summary of Common Faults and Solutions of Yaskawa Robots and Accessories (9-17)

09. Robot oil leakage? Cause: 1. Improper maintenance; 2. Corrosive parts damage, etc. Solution: Check the location of the oil leak and confirm the parts caused by the oil leak. It is possible to accurately determine the parts caused by oil leakage by checking drawings, etc. 10. Robot ...

Yaskawa Robotics - technical performance characteristics of dresspacks for industrial robots Yaskawa Robotics - technical performance characteristics of dresspacks for industrial robots

1. Technical performance characteristics of industrial robot dresspack - intelligence The reason why the intelligent type is placed at the back of the Z is because compared with the mainstream demand for robot dresspacks in the market (that is, strong, fast, and accurate), it is not the most urgent for the time being. This also reflects the ...

Product classification of Yaskawa servo motors Product classification of Yaskawa servo motors

Yaskawa Electric is a professional manufacturer in the field of motion control, is the first company in Japan to do servo motors, its products are known for stable and fast, cost-effective, is the world's largest sales, the most used servo brand. In China, Yaskawa Servo has occupied the largest market for many years ...

Yaskawa servo drive fault code and handling method Yaskawa servo drive fault code and handling method

1. If the fault code on the Yaskawa servo drive is UV1, it means that the low voltage of the main circuit is lower than the low voltage standard of 200V, at this time, we need to check whether there is a problem with the wiring of the power supply; 2. If the ...

Yaskawa inverter fault display Ou how to deal with the fault when running at high speed Yaskawa inverter fault display Ou how to deal with the fault when running at high speed

1. The cause of the failure may be that the power plug is not plugged in properly. Solution: Check and plug in the power plug. 2. The sensor is damaged and the resistance value is wrong. Solution: Replace the sensor. 3. The fuse is blown out. Solution: Repair and replace the fuse ...

Yaskawa Robotics - the main technology of the robot control system Yaskawa Robotics - the main technology of the robot control system

(1) Open modular control system architecture: using distributed CPU computer structure, divided into robot controller (RC), motion controller (MC), optoelectronic isolation I/O control board, sensor processing board and programming teaching box, etc. The Robot Controller (RC) and the programmed teaching pendant are connected via a string...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top