Excellent motor drive function
Advanced motor drive skills
All motors can be controlled – whether they are driving induction motors or synchronous motors (IPM motors/SPM motors) – with high utility current vectoring.
Inverters for induction motors and synchronous motors can be used universally
It is possible to switch between induction motor and synchronous motor after parameter setting
Equipped with a wealth of self-learning functions
Built-in a variety of self-learning methods, whether it is driving an induction motor or a synchronous motor, it can give full play to the driving function
The self-learning content also includes the customer's machinery
Online self-learning equipped with new methods
Instantaneous power outage measures that fit the purpose
Two types of instantaneous power failure compensation functions can be selected
It can be used for sensorless operation of induction motors or synchronous motors
Instantaneous power failure compensation of 2 seconds* is possible
It starts with the environmental performance of the drive
energy conservation
Advanced motor drive skills
The energy-saving operation of the inverter can be used to complete the high-efficiency operation of the induction motor.
More energy efficient when used in synchronous motors
The simultaneous use of high-efficiency synchronous motors and energy-saving control of inverters can further improve the energy-saving effect compared to induction motors.
Environmental resistance
Environmental resistance planning
We also have reinforced products that are resistant to moisture, dust, oil, vibration, and other environments
We also have a maintenance structure such as dustproof and drip-proof IP54 ∗
RoHS compliant
The regulated products comply with the RoHS (European Restriction on the Use of Specified Hazardous Substances) directive
Noise reduction
The Swing PWM method reduces the screeching noise while suppressing the electromagnetic disturbance
Press the higher harmonics of the power supply
DC reactor for higher harmonic pressing (22 kW or more) as standard
12-phase and 18-phase rectifier options are available∗ and higher harmonic filters are available
Safe environment
Comply with safety regulations
Compliant with EN954-1 Cat.3 and IEC/EN61508 SIL2
The EDM (External Device Monitor) function has been added to supervise the operation of safety functions
Safe abort in the event of a power outage
Equipped with the Kinetic Energy Back-up (KEB) function, which allows the motor to be quickly and safely decelerated and stopped without running freely in the event of a power failure
Industry-leading function for changing mechanical grades
Accelerate compact planning for machine miniaturization
The combination of a miniaturized inverter and a compact, lightweight synchronous motor accelerates the process of machine miniaturization
After the side-by-side device, the size of the device can be further reduced
A heatsink type is available
Two layers of additional functions make the machine more miniaturized
Customize the drive to your liking Equipped with the visual programming function DriveWorksEZ ∗
Using a computer, through the drag-and-drop operation of the mouse, it can be easily according to the customer's mechanical specifications
Customized drives. Special actions and new detection functions can be programmed and loaded into the inverter.
Easy commissioning
Proactively set the appropriate parameters
Environmental resistance
Equipped with a USB port for easy connection to a computer
Connect with your computer via the USB port
Really reliable braking function
Using the excitation braking function, it can also be used for emergency braking without braking resistance
The model with a built-in braking transistor has been expanded, and a braking resistor can be increased to achieve greater braking power
Longevity number planning
Planned life of the inverter: 10 years
Motor life - synchronous motors have no copper loss of rotor and low bearing temperature, so the life of motor bearings is about 2 times that of induction motors
Reminder signal output for diagnosis and prediction of life expectancy
|
More on that
|
How to set the parameters of Yaskawa H1000 inverter multi-stage speed?
Yaskawa H1000 inverter parameter model setting steps:
Yaskawa H1000 hoisting using debugging steps (with PG ) No. Name Optimal value
A 1-02 Control Mode Selection 3: With PG Vector Control
A 1-03 Initialization 2220: 2 Wire Initialization
A ...
|
|
Yaskawa inverter - what are the common measures for anti-interference of high-voltage inverter?
(1) The E end of the high-voltage inverter should be connected to the shell of the control cabinet and the motor, and should be connected to the ground, and the grounding resistance should be less than 100Ω, which can absorb surge interference.
(2) The input or output of the high-voltage inverter is equipped with an inductive magnetic ring filter. Flat and 3-4 turns, helps to inhibit ...
|
|
Common types of Yaskawa drives
H1000
The new Yaskawa "H1000" heavy-duty inverter plays a stable and outstanding role in the heavy-duty industrial field!
Capacity range
200V class 0.4-110kW
400V class 0.4 - 355kW
apply
Lifting Machinery, Fluid Machinery, Metalworking Machines ...
|
|
Causes and solutions of Yaskawa servo drive fault code R10
1. The acceleration/deceleration time constant is too small. Increase the acceleration/deceleration time constant.
2. The torque limit value set by the controller is too small. Increase the torque limit value.
3. The motor cannot start due to the insufficient torque caused by the drop in power supply voltage.
4. Check the power capacity.
...
|
|
Yaskawa Robotics - Top 10 Trends in the Industrial Robot Automation Industry
1. The demand for smart sensors is increasing
Quality inspection is a key component in all industries. Analyzing everything from food to phone covers ensures that consumers can trust the goods they receive. Smart sensors enable manufacturers to more efficiently handle this ...
|
|
Yaskawa MOTOMAN servo drive fault repair case summary (3-4)
3. When the oscilloscope checks the current monitoring output of the driver, it is found that it is all noise and cannot be read;
Cause of failure: The current monitoring output is not isolated from the AC power supply (transformer).
Solution: It can be detected and observed with a DC voltmeter.
4、LE ...
|
|
Yaskawa inverter - what are the control methods of low-voltage inverter?
1. Sinusoidal pulse width modulation
Sinusoidal Pulse Width Modulation (SPWM) is characterized by simple structure of control circuit, low cost, good hardness of mechanical characteristics, and can meet the smooth speed regulation requirements of general transmission, and has been widely used in various fields of the industry.
However, this control ...
|
|
Common faults of Yaskawa inverters
The switching power supply is damaged
Switching power supply damage is the most common fault of many inverters, usually caused by short circuit in the load of switching power supply, in the design of switching power supply circuits of many inverters, Yaskawa inverter is relatively successful.
OH failure
Old...
|
|
Yaskawa servo drive parameters
PN000 function selection N.0010 (setting value) 0th position: set the direction of rotation of the motor; Set "1" to change the rotation of the motor in reverse. 1st position: Set the control mode to: "1" position control mode.
PN200 Command Pulse Input Mode Function Selection N.0101 (Set Value) "1" Positive ...
|
|
Yaskawa servo alarm C90 (AC9) troubleshooting method
1. Analysis of the causes of Yaskawa servo alarm C90 (AC9):
1. The encoder cable is broken or the encoder plug is made in poor process (there are also wiring errors in the alarm of the new machine);
2. The servo drive itself is faulty;
3. Environmental interference, caused by poor connection: ...
|
|
What is the difference between the origin setting of Yaskawa robot, the location of the second origin, and the location of the origin of the job?
What is the difference between the origin setting of Yaskawa robot, the location of the second origin, and the location of the origin of the job?
Origin Setting: Lets you set the origin and initial position of each axis.
The robot → the origin position → point display, and select the axis and robot you want to set
1. Write origin data → point ...
|
|
A brief introduction to Yaskawa inverter V1000
Yaskawa inverter V1000 series has amazing performance, wide range of uses, simple use and maintenance, and user-programmed function, breaking through the previous small inverter in every aspect and improving the level of all small machines.
1 multi-purpose (synchronous motor can also be driven).
Detergent ...
|
|
ATI+Yaskawa work together to achieve force-controlled weld grinding of complex workpieces
As we all know, the traditional material removal work is done manually, the cost is high, the efficiency is low, the accuracy of the parts is greatly affected by the manual, and the safety of workers is not effectively guaranteed, so what can be done to effectively solve these problems?
Today, I will take you to understand the machine ...
|
|
Replacement of Yaskawa inverter spare parts
The inverter is composed of a variety of components, some of which will gradually decline and age after the temporary task, which is also an important cause of the failure of the inverter, in order to ensure the temporary normal operation of the equipment, the following devices should be replaced on a regular basis:
2.1 Cooling fan
Frequency converters ...
|
|
Summary of Common Faults and Solutions of Yaskawa Robots and Accessories (9-17)
09. Robot oil leakage?
Cause:
1. Improper maintenance;
2. Corrosive parts damage, etc.
Solution: Check the location of the oil leak and confirm the parts caused by the oil leak. It is possible to accurately determine the parts caused by oil leakage by checking drawings, etc.
10. Robot ...
|
|
Yaskawa Robotics - technical performance characteristics of dresspacks for industrial robots
1. Technical performance characteristics of industrial robot dresspack - intelligence
The reason why the intelligent type is placed at the back of the Z is because compared with the mainstream demand for robot dresspacks in the market (that is, strong, fast, and accurate), it is not the most urgent for the time being. This also reflects the ...
|
|
Product classification of Yaskawa servo motors
Yaskawa Electric is a professional manufacturer in the field of motion control, is the first company in Japan to do servo motors, its products are known for stable and fast, cost-effective, is the world's largest sales, the most used servo brand. In China, Yaskawa Servo has occupied the largest market for many years ...
|
|
Yaskawa servo drive fault code and handling method
1. If the fault code on the Yaskawa servo drive is UV1, it means that the low voltage of the main circuit is lower than the low voltage standard of 200V, at this time, we need to check whether there is a problem with the wiring of the power supply;
2. If the ...
|
|
Yaskawa inverter fault display Ou how to deal with the fault when running at high speed
1. The cause of the failure may be that the power plug is not plugged in properly.
Solution: Check and plug in the power plug.
2. The sensor is damaged and the resistance value is wrong.
Solution: Replace the sensor.
3. The fuse is blown out.
Solution: Repair and replace the fuse ...
|
|
Yaskawa Robotics - the main technology of the robot control system
(1) Open modular control system architecture: using distributed CPU computer structure, divided into robot controller (RC), motion controller (MC), optoelectronic isolation I/O control board, sensor processing board and programming teaching box, etc. The Robot Controller (RC) and the programmed teaching pendant are connected via a string...
|
|