1. Check whether all switches are in the disconnected position;
2. Check whether there are foreign objects in the UPS uninterruptible power supply cabinet and transformer; Check whether the flat cable connection is correct and whether it is loose;
3. Check whether the connected plug is tightened and whether the wiring is correct: whether the ground wire of the main cabinet and the battery cabinet is connected;
4. Check that the vent has a debris gambling plug, and manually roll the fan to see if it is normal.
As an important emergency equipment, it plays an important role in all walks of life. As a backup energy storage power supply for large companies such as shopping malls, banks, and base stations, it has the most important position, in addition to the function of protecting equipment against power failure, it also plays the role of voltage stabilization. In the event of a power outage, if there is no UPS uninterruptible power supply, people will suffer a lot of loss in many aspects.
|
More on that
|
The difference between vector and general use of inverter - Schneider
1. The control accuracy of the vector type is higher than that of the general-purpose type.
2. The vector type has a large output torque at low speed, which can make the motor get a larger starting torque, which is suitable for application in the occasion of heavy load starting, such as: high-power long belt, hoist, etc. If used in some of the more common fields ...
|
|
Schneider inverter ATV32 book type performance and advantages
Schneider ATV32 book inverter has built-in programmable controller function, flexible and intelligent; Integrated safety functions, 30% cost savings compared with external security modules; First-class Schneider patented synchronous motor open-loop control technology; Book-type design, support side-by-side installation, space-saving; Many...
|
|
Deterioration site and the principle of higher harmonic generation - Schneider
1. Electrical equipment will produce higher harmonics when it produces abnormality and deterioration, and the abnormality and deterioration of motors, loads, and inverters are used to distinguish the higher harmonics from 2 to 40 times, and the data is changed by FFT, and the analysis is made on the basis of the analysis data of long-term savings.
|
|
The selection method of inverter power - Schneider
The system power is equal to the product of the inverter power and the motor power, as long as both are operating at a higher power, the system power is higher. From the power point of view, when selecting the power of the inverter, the following points should be noted:
...
|
|
Schneider power supply configuration UPS backup battery method
In order to ensure that the APCUPS power supply can continue to provide high-quality power to the computer in the event of a power outage, it is particularly important to equip the battery backup battery. When the frequency load does not agree to be supplied with power, the backup time of the UPS battery in the communication room should be greater than the time from the suspension of the mains power to the recovery or until the generator set is normal.
|
|
Circuit breaker mechanical characteristics tester operation steps - Schneider circuit breaker
Circuit breaker action time test.
The closing and opening control lines of the circuit breaker mechanical characteristics tester are respectively connected to the secondary control line of the circuit breaker, and the lead wires of each break of the circuit breaker are connected to the mechanical characteristics of the circuit breaker with the test wiring.
|
|
Schneider DC air open up plus or minus? How to connect the incoming and outgoing lines?
The air switch is divided into the upper inlet line and the lower inlet line of the power supply, 1 is - 3 is + 2 is + 4 is - when the upper line is inlet, 2 is + 4 is - This is related to the internal trip curve.
DC circuit breaker is used for DC system operation method conversion or fault removal ...
|
|
How to choose a Schneider circuit breaker?
First, calculate the value of the current of each branch
(1) Purely resistive loads, such as bulbs, electric heaters, etc., are directly divided by the indicated power by voltage, that is, the formula I = power/220v; For example, a 20w bulb, branch current I=20W/220=0.09A electric air ...
|
|
Analysis of the reasons why the contact of Schneider contactor is not reliable
The unreliable contact touch will increase the touch resistance between the dynamic and static contacts, resulting in the high temperature of the touch surface, making the surface touch become a point touch, and even showing a non-conduction phenomenon. The reasons for this failure are:
(1) There are ...
|
|
Frequency converters and their control – Schneider
AC inverter is the result of the high development of microcomputer and modern power electronics technology. The microcomputer is the center of the inverter, and the power electronics form the main circuit of the inverter. As we all know, the frequency of communication electricity sent from power plants is stable and constant, in our country it is 50 weeks per second ...
|
|
Common maintenance problems for Schneider drives
1. Why is the inverter used for fan and pump loads to save energy?
According to the basic law of fluid mechanics, it can be seen that the fan pump load is a typical square rotation load, and its primary feature is that the speed n has the following relationship with the torque T and the load power P: T∝n2, P∝n3. ...
|
|
Schneider inverter maintenance inspection steps
1. Check whether the appearance of the inverter is in good condition, including whether the indicator light is in normal operation, whether the task control function of the operation panel is complete, and carefully observe the appearance of the inverter in operation, and do the corresponding recording operation; When repairing the inverter, check whether the voltage value and current value exceed the promised ...
|
|
Commissioning steps for Schneider drives
1. Type recognition: Recognize whether the type of inverter is common with the type of inverter purchased.
2. Transportation acknowledgement: After opening the package, check whether the inverter is damaged during transportation.
3. Voltage recognition: the power supply voltage on the site should be borne by the inverter.
|
|
Features of Schneider explosion-proof inverter box
1. Aluminum alloy shell or steel plate welding, surface spraying;
2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies;
3. It is mainly adjusted by changing its output frequency to adjust the speed of ordinary three-phase asynchronous motor, so as to reach the production process.
|
|
Precautions for the selection of Schneider foot switches
The foot switch series is XPE, and it should be noted when selecting:
1) Raw materials: metal and plastic, which are used in heavy-duty, high-risk, light-duty, low-risk occasions.
2) Pedal: divided into single pedal and double pedal (type end plus D).
3) With or without maintenance cover ...
|
|
Inverter control motor speed method - Schneider
1. Why can the rotation speed of the motor be changed freely?
Motor rotation speed unit: r/min number of rotations per minute, can also be expressed as rpm.
Example: 2-pole motor 50Hz 3000 [r/min]
4-pole motor 50Hz 1500 [r/min]
Conclusion:...
|
|
Turbine flowmeter selection factor - Schneider
Turbine flowmeter is a kind of speed appearance, it has high precision, good repeatability, no zero drift, high range ratio, simple structure, few moving parts, high pressure resistance, wide measurement scale, small size, light weight, small pressure loss, convenient repair and other advantages, turbine flowmeter has high quality ...
|
|
Schneider Intermediate Relay Model Letter Meaning
RXM: Schneider's miniature center relay
The first 2: indicates the number of contacts, and the normally open contact is 2
LB: Indicates that the product has LED light
The second 2: indicates the number of contacts, and the normally closed contacts are 2
BD: Indicates that the supply voltage used is DC 24V
...
|
|
Analysis of the causes of Schneider touch screen touch deviation
(1) Fault--: Contact error
Phenomenon 1: The direction of the finger does not coincide with the mouse arrow.
Reason 1: After installing the driver, there is no vertical contact with the bullseye center when correcting the bearing. Solution 1: Re-align the bearing.
Phenomenon 2: Some districts ...
|
|
Schneider diode selection experience and substitution method
1. Selection of detection diode
Point-contact germanium diodes are generally used for detection diodes, such as 2AP series. When selecting, the detection diode with high operating frequency, small reverse current and large forward current should be selected according to the specific requirements of the circuit. Although the detection and rectification of ...
|
|