1. Construction preparation. Including the preparation of operating conditions (construction skills documents and detailed design documents), construction organization design, equipment list, data budget, and list of machined parts;
2. Cooperate with civil engineering majors to do a good job of pre-embedding and reserving work;
3. Cooperate with process equipment, pipelines and other professionals to confirm the location of measurement and control points and do a good job in the installation of primary (source) components;
4. Manufacturing and installation positioning of various metal brackets (surface equipment brackets, pipeline brackets, brackets for cable trays), bridge frames (slot boxes, trays, ladder frames), enlarged pipes, outer dials (boxes, cabinets), operating tables, etc., and assist in the manufacture of containers and processed parts;
5. Appearance out of the warehouse, unpacking inspection and monomer adjustment;
6. On-site detection of the appearance, installation of the control outdoor surface in place, piping, wiring, calibration and wiring of the outer surface panel cabinet, and preparation of line resistance;
7. Laying of impulse pipelines and heat tracing pipelines, grinding and installation of valves, laying of surface air source pipes and pneumatic pipelines, pressure testing and leak testing;
8. Installation of electrical protection pipes and flexible pipes, laying of cables and compensation wires, cable insulation test and wire finding, grounding system installation and grounding resistance test;
9. Equipment insulation, pipeline anti-corrosion and heat insulation;
10. Debugging of automatic control appearance system: joint debugging of detection system, control system, interlocking and emergency shutdown system (ESD) and sloppy control system (DCS) to ensure that the action is correct;
11. Cooperate with the process professional system to purge, test pressure, and sweep the end of the project;
12. Cooperate with the process monomer test run and feeding test;
13. Delivery, acceptance, and production.
|
More on that
|
Switching power supply circuit fault phenomenon - Schneider
1. The power supply voltage of the secondary load is 0V. There is no response after the inverter is powered on, there is no indication on the operation display panel, and the 24V and 10V voltages of the measurement and control terminals are 0V. Check that the charging resistance or pre-charging circuit of the main circuit is correct, which can be identified as a switching power supply fault. The overhaul process is as follows:
1 ...
|
|
Schneider instrumentation fault diagnosis method
1. Percussion hand pressure method
When we use the instrument, we often encounter the phenomenon that the instrument is running well and badly, and most of this phenomenon is caused by poor contact or virtual welding. In this case, percussion and hand pressure can be used.
The so-called "percussion" is the response to the ...
|
|
Key points of maintenance of Schneider battery
(1) Insulating pads should be arranged in the maintenance channel of the battery pack.
(2) It is strictly forbidden to use batteries of different manufacturers, different capacities and different models in the same system.
(3) VRLA batteries do not need to be charged for the first time before use, but should be recharged. Replenish the charge ...
|
|
Precautions for trial operation of Schneider motors
1. Check during the test run of the motor
1.1 Before the motor starts
It is necessary to carefully check whether the insulation resistance is qualified, check whether the wiring of the secondary circuit is correct, and the inside of the motor should be boring, clean and free of debris. Investigate whether the fastening bolts of the motor are loose and the bearing is ...
|
|
The form of power input and output - Schneider
1. Single-phase input/single-phase output:
If the capacity is relatively small, the single-entry UPS hanging on any phase of the mains will not be troublesome to the three-way distribution balance of the mains, the load capacity is small, and the output line diameter (current value) of the single-phase output is not ...
|
|
Schneider seizes the opportunity of e-commerce
Beijing, China, 24 August 2021 – Looking at the history of the logistics industry, the changes brought about by the development of e-commerce in recent years are rare. According to Digital Commerce 360, in 2020, United States customers spent $861.12 billion online, a year-on-year increase.
|
|
How can industry be high-quality and sustainable? - Schneider
Sanya, China, October 21, 2021 – In the context of the ever-changing global development situation and the increasingly urgent response to carbon neutrality, Ruan is moving towards carbon neutrality together with cost reduction and efficiency increase, which has become the focus of attention of many industrial enterprises. As a global digital transformation specialist in power management and automation...
|
|
There is a remote code execution vulnerability in Schneider industrial equipment
Recently, Armis security researchers have reported that Schneider Electric's programmable logic manipulators (PLCs) have serious and unpatched gaps in long-distance code fulfillment, allowing intruders to manipulate their various industrial systems.
Schneider ...
|
|
Schneider appeared at the 5th China Power Distribution Technology Summit Forum
Beijing, China, September 14, 2020 – Today, the 5th China Power Distribution Technology Summit Forum 2021, held by China Electric Power Research Institute Co., Ltd. and the Science and Technology Development Service Center of China Electric Power Council, opened in Beijing. The theme of this forum is "Supporting the Strategic Policy of Carbon Peaking and Carbon Neutrality, Building a ...
|
|
Introduction to Schneider inverter fault code and maintenance method
1. If the fault code presented on the Schneider inverter is AnF, it means that the load of the inverter has slipped, that is, the speed of the encoder does not match the initial value. First of all, we need to check whether the parameters of the motor are stable and the size of the load, ...
|
|
Advantages of the Schneider Magelis GXU touchscreen
1. Save capital contribution
Focus on central function (true color LCD, serial communication interface, USB connection, Ethernet interface, etc.)
2. Save space
Compact structure planning, only 38mm thick
The fuselage is reserved for communication wiring ...
|
|
Frequency converter control motor leakage solution - Schneider
Because the current at the input and output ends of the inverter contains high-frequency components, the leakage current formed by the high-frequency components when the inverter is driven is greater than that when the grid power supply is supplied. Because there are many varieties of circuit breakers, in some cases, even the inverter wires and motors ...
|
|
Inverter braking resistor selection – Schneider
In the process of fast parking, because of the inertia, a lot of regenerative electric energy will occur, which will directly act on the intermediate DC part of the inverter, and if this part of the electric energy is not consumed, the inverter will be faulty or the inverter will be damaged. The braking resistor is used to dissipate this part of the electrical energy. ...
|
|
Analysis of the causes of Schneider touch screen touch deviation
(1) Fault--: Contact error
Phenomenon 1: The direction of the finger does not coincide with the mouse arrow.
Reason 1: After installing the driver, there is no vertical contact with the bullseye center when correcting the bearing. Solution 1: Re-align the bearing.
Phenomenon 2: Some districts ...
|
|
Deterioration site and the principle of higher harmonic generation - Schneider
1. Electrical equipment will produce higher harmonics when it produces abnormality and deterioration, and the abnormality and deterioration of motors, loads, and inverters are used to distinguish the higher harmonics from 2 to 40 times, and the data is changed by FFT, and the analysis is made on the basis of the analysis data of long-term savings.
|
|
Selection and control of the inverter installation - Schneider
Frequency converters are widely used equipment in modern industry. If you want to complete the functions of soft stop, soft start, stepless speed regulation or special requirements for speed rise and fall, you need the more advanced speed control equipment in modern asynchronous motors - frequency converters. The main circuit of the equipment is selected to communicate - DC - communication ...
|
|
Schneider Instrumentation Classification
1. Industrial automation appearance and control system. This is generally referred to as PA, FA in foreign countries. PA is called process automation, and FA is called factory automation. The appearance and control system used in process automation and factory automation belong to this category, and some parts of the appearance of analytical instruments and electrical instruments also belong to the ...
|
|
The difference between circuit breaker and air opening - Schneider
An air switch, also known as an air circuit breaker, is a type of circuit breaker. It is a switch that only needs the current in the circuit to exceed the rated current will be actively disconnected, and is generally used to avoid circuit overload and short-circuit maintenance (some also have low voltage maintenance functions) can not maintain electric shock, to put it bluntly, it is ...
|
|
Troubleshooting methods in electrical circuit control - Schneider
The troubleshooting method of the electrical control line is not the same as a thousand people, and various methods can be used cooperatively, but do not copy the rigid set. In general, investigative research can help us to find out the problem. The experimental method can not only find out the fault phenomenon, but also find the fault location or fault circuit; Logic...
|
|
Schneider's method of improving the power factor of UPS power supplies
One. The significance of the progressive power factor.
1. Make full use of the ability of power equipment.
Each power supply unit has additional capacity, i.e. depending on the power. The total power output of the power supply equipment S, - part of the active power, the other part is the reactive power, the smaller the ...
|
|