What are the fault codes of Yaskawa inverter

Create Date: 2024-8-30 12:03:23|Source: YASKAWA/Yaskawa

The fault codes of Yaskawa inverters are as follows:

OC overcurrent;

PG wiring is disconnected or wiring is incorrect;

GF output ground fault ground short circuit ;

PUF fuse blowing fuse blowing ;

OV Main Loop Overvoltage Main Loop Overvoltage;

UV1 Main Circuit Undervoltage Main Circuit Undervoltage;

UV2 control loop undervoltage control power failure;

UV3 Shock Prevention Circuit Failure Impact Prevention Circuit Failure;

PF input phase loss, main loop voltage fault;

LF Output Phase Missing Output Phase Missing;

OH (OH1) heatsink overheating;

FAN internal fan failure Inverter internal cooling fan failure ;

OH4 Motor Overheating Warning 2 Motor Overheating Fault;

RH Brake resistor overheats Mounted brake resistor overheats;

OL1 Motor overload Motor overload.
What are the fault codes of Yaskawa inverter

More on that
Analysis of the causes of the alarm of Yaskawa servo drive 300 Analysis of the causes of the alarm of Yaskawa servo drive 300

1, Maybe the connection of the external resistor is bad, falling off and disconnecting will cause an alarm, we can check the wiring. 2. It may be that the jumper wire of the resistor connection terminal B2-B3 falls off, and then check if the jumper wire falls off. 3. It may be that the resistor capacity ...

A brief introduction to Yaskawa inverter V1000 A brief introduction to Yaskawa inverter V1000

Yaskawa inverter V1000 series has amazing performance, wide range of uses, simple use and maintenance, and user-programmed function, breaking through the previous small inverter in every aspect and improving the level of all small machines. 1 multi-purpose (synchronous motor can also be driven). Detergent ...

How to deal with the BB flashing of Yaskawa servo drive How to deal with the BB flashing of Yaskawa servo drive

1. Check whether the power wiring is in good contact, and if the contact is bad, you need to unplug the power supply and re-wire. 2. Check whether the wiring between the servo drive and the host is in good contact, and if the contact is bad, the wiring needs to be removed and rewired. 3. Check the connection between the main machine and the servo drive.

Product classification of Yaskawa servo motors Product classification of Yaskawa servo motors

Yaskawa Electric is a professional manufacturer in the field of motion control, is the first company in Japan to do servo motors, its products are known for stable and fast, cost-effective, is the world's largest sales, the most used servo brand. In China, Yaskawa Servo has occupied the largest market for many years ...

Which parameter is jitter adjusted for Yaskawa servo motor? Which parameter is jitter adjusted for Yaskawa servo motor?

First, the servo dispute settings are too large, and it is recommended to readjust the servo parameters manually or automatically. Second, make sure that the initial value of the time constant of the velocity feedback filter is set to zero, and try increasing the initial value. Thirdly, the electronic gear ratio setting is too large, it is recommended to restore ...

Yaskawa inverter reports Uv1 fault code solution Yaskawa inverter reports Uv1 fault code solution

Yaskawa inverter Uv1 fault name: main circuit undervoltage If the operation command is not entered (the inverter is stopping), the following conditions occur. 1. The DC voltage of the main circuit is lower than the set value of L2-05 (the detection value of the undervoltage (UV) of the main circuit). 2. 200V class: about 190V ( ...

How to deal with Yaskawa servo alarm 840? How to deal with Yaskawa servo alarm 840?

1. Encoder malfunction. When the power is turned on again and this alarm still occurs, it is possible that the servo motor is faulty, and the servo motor is replaced; 2. Encoder malfunction due to noise and other interference. Correct handling of the wiring around the encoder (separating the encoder cable from the servo motor ...

What are the faults of Yaskawa inverter? What are the faults of Yaskawa inverter?

The following are the common faults of the inverter and how to deal with them 1) OC Over Current This is the most frequent failure of the inverter, and it is divided into external and internal causes in the analysis of causes. External causes: mechanical structure and parameter setting, open-loop control ...

Advantages of Yaskawa Industrial Robots Advantages of Yaskawa Industrial Robots

Advantages of Yaskawa Industrial Robots   Generalization Programmable industrial robots that support multiple degrees of freedom of motion make the application more flexible. Although not human, compared to many general-purpose industrial automation aircraft (a class dedicated to industrial applications or customized mechatronic solutions), ...

Yaskawa servo motor - the selection step of servo control Yaskawa servo motor - the selection step of servo control

1. Determine mechanical specifications, load, rigidity and other parameters; 2. Confirm the action parameters, stroke, accuracy, acceleration and deceleration time, cycle, moving speed, etc.; 3. Select motor inertia, load inertia, motor axis conversion inertia, and rotor inertia; 4. Select the motor back ...

How to choose a Yaskawa inverter model How to choose a Yaskawa inverter model

1. Specifications and parameters of the motor The inverter drives the motor during use, so the inverter can be selected from the perspective of the motor to select the model and specification. First of all, we must first understand the specifications and parameters of the motor. You can use Yaskawa inverter ...

Advantages of Yaskawa linear servo motors Advantages of Yaskawa linear servo motors

In terms of speed: the servo motor + ball screw mode may resonate due to the change of load and mechanical design and installation when running at high speed, and the speed will be limited; The linear servo motor belongs to the direct drive, so the only factor that affects the speed is the linear servo motor itself.

Analysis of fault codes of Yaskawa inverter Analysis of fault codes of Yaskawa inverter

Analysis of the fault code of Yaskawa inverter, for reference only: OC Overcurrent The output current of the inverter exceeds the overcurrent detection value · GF grornd Favlt Grounding The ground current on the output side of the inverter exceeds 50% of the rated output current of the inverter ...

Yaskawa inverter fault display Ou how to deal with the fault when running at high speed Yaskawa inverter fault display Ou how to deal with the fault when running at high speed

1. The cause of the failure may be that the power plug is not plugged in properly. Solution: Check and plug in the power plug. 2. The sensor is damaged and the resistance value is wrong. Solution: Replace the sensor. 3. The fuse is blown out. Solution: Repair and replace the fuse ...

Yaskawa Robot - Industrial Robot Maintenance Knowledge Q&A Yaskawa Robot - Industrial Robot Maintenance Knowledge Q&A

Q: How often is the robot maintained? A: Generally speaking, the frequency of scheduled maintenance of the robot should be determined on a case-by-case basis. It is generally recommended to carry out a full maintenance every 3-6 months, but for high-intensity and long-working robots, more frequent maintenance may be required.

Analysis of common fault codes of Yaskawa servo drive Analysis of common fault codes of Yaskawa servo drive

A.020 A.02 User Parameters and Number Check Abnormalities The data of the internal parameters of the servo unit is abnormal A.021 A.02 Parameter Formatting Abnormality The data of the internal parameters of the servo unit is abnormal A.022 A.02 Abnormal system parameters and number check The data of the internal parameters of the servo unit is different ...

Yaskawa inverter fault code description and corresponding fault causes Yaskawa inverter fault code description and corresponding fault causes

When the Yaskawa inverter fails, the operator will display the fault content, cut off the output, and the motor will decelerate and stop freely. The following is a description of the fault alarm code of Yaskawa inverter and the corresponding fault reason, which is for reference only. OC Overcurrent ...

Yaskawa SGD7S-120A00B202 servo driver alarm fault recovery Yaskawa SGD7S-120A00B202 servo driver alarm fault recovery

1. First, confirm the alarm code. The alarm code is different for each servo drive, so you need to consult the corresponding equipment manual or contact the manufacturer for a specific list of alarm codes. 2. Determine the cause of the fault according to the alarm code. Different alarm codes correspond to different fault types, which can be ...

Yaskawa Robot - the basic function of the robot control system Yaskawa Robot - the basic function of the robot control system

(1) Memory function: store operation sequence, motion path, motion mode, motion speed and information related to production process; (2) Teaching function: offline programming, online teaching, indirect teaching. There are two types of online teaching: teaching box and guided teaching; (3) With ...

How to establish an external start signal for Yaskawa Robot DX100 How to establish an external start signal for Yaskawa Robot DX100

1. Enter the editing mode of Yaskawa robot first 2. Select "Function Effective Setting" for setting 3. Select "Allow" to start the appointment 4. Click Settings to enter "Appointment Activation (Connection)" 5. Set the input signal and output signal you need.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top