Precautions when using Autonex safety light curtains

Create Date: 2024-8-30 12:03:23|Source: Autonics/Autonics

Cover the safety light curtain with your hands and observe whether the indicator light conversion is normal.

                               Precautions when using Autonex safety light curtains

During the use of the punch photoelectric protection device, the orientation of the photoelectric protection device shall not be changed at will.

In the protection zone, the light curtain should be blocked by hand, and the machine should be able to stop the operation immediately.

When the slider is at the bottom dead center (180 degrees), the light curtain is blocked, and the machine tool slider should be able to return.

For presses that can only complete the top dead center protection, when the slider stops on the top dead center and the slider blocks the light curtain, the next operation cannot be started.

After replacing the mold, it is necessary to adjust the safety distance and safety orientation of the protection device by the special manager.

When disassembling and assembling the light curtain and transmission line, the power should be turned off first, and it is necessary to be operated by professionals to prevent the occurrence of danger.

Check that the transmitter and receiver of the safety light curtain are installed correctly with the respective cables, and that the cable terminals are accurately connected to the power supply and controller.

After about 1 second, if the yellow indicator light of the transmitter is stable, the indicator light of the receiver is all turned off, indicating that the light curtain sensor has entered the normal operating condition.
More on that
Autonex launches a new product - multi-channel pressure sensor PSM series Autonex launches a new product - multi-channel pressure sensor PSM series

The multi-channel pressure indicators of the PSM series can display the measured values of up to 4 or 8 channels of analogue pressure sensors. When used in conjunction with our PSS series pressure sensors, the sensor type, pressure type and range can be automatically recognized without additional settings. Users can also easily ...

Wiring of the load cell – Autonex Wiring of the load cell – Autonex

The load cell can be wired in two different ways with input and output: One is the four-wire connection method The load cell of the four-wire connection method has no special requirements for the secondary instrument panel, and it is very fast to use, but when the cable is long, it is very easy to be affected by the working temperature.

Autonix proximity switch Autonix proximity switch

Proximity switches are the most commonly used solution for touchless detection. The most commonly used proximity sensor is inductive, that is, through electromagnetic waves, to sense metal objects near the detection surface of the sensor; In practice, this is a very simple tool for the detection of metal objects from one to two inches.

Ultrasonic flow sensor principle Ultrasonic flow sensor principle

Ultrasonic flow sensor is a new type of general-purpose time-difference multi-function ultrasonic sensor suitable for industrial environments, mainly using low-voltage multi-pulse balanced emission acceptance technology, which can be mainly applied to measure the flow of most clean and uniform liquids without large concentrations of suspended particles or gases.

TZ4ST-24R Autonox Thermostat Advantages: TZ4ST-24R Autonox Thermostat Advantages:

Dual PID auto-adjustment function There are high-speed response modes and slow reaction modes in the PID function. When you want to reach the desired value quickly, use the high-speed mode (PIDF mode) When you want to minimize overshoot, use slow mode (PIDS mode) ...

Introduction to the resolution of the Autonoix encoder Introduction to the resolution of the Autonoix encoder

Depending on the resolution supported by the encoder, encoders can be divided into marker encoders, HD encoders, and Full HD encoders. The higher the frame rate, the clearer the video. 1. What does the resolution of the encoder mean? The resolution of the encoder refers to the encoder passing through a line or a dark line (also ...

Autonicx brought a full range of innovative products to the fair Autonicx brought a full range of innovative products to the fair

On November 4, 2014, Ortonicus attended the 2014 Industrial Automation Exhibition held at the Shanghai New International Expo Center. With the theme of "high-end, intelligent and green", this exhibition has a total of CNC machine tools and metalworking exhibition, industrial automation exhibition, industrial robot exhibition, new energy and electric ...

Sensors in the neighborhood of life applications Sensors in the neighborhood of life applications

The sensor is a kind of detection device, which can feel the measured information, and can transform the felt information into an electrical signal or other required form of information output according to certain rules, so as to meet the requirements of information transmission, processing, storage, display, recording and control. ...

The principle, function and application field of Autonex's products The principle, function and application field of Autonex's products

Panel meter, also known as panel table or meter header, the full name is panel mounted instrument (panel mounted instrument), English Panel Meter. Because this kind of instrument is installed and fixed on the surface of the equipment for viewing and operation, it is called a panel table and is a functional part of the screen equipment. ...

Precautions for the use of through-beam photoelectric sensors - Autonex Precautions for the use of through-beam photoelectric sensors - Autonex

1. Avoid strong light sources Photoelectric sensors can generally operate stably when the ambient illumination is high. However, avoid facing the optical axis of the sensor with strong light sources such as sunlight and incandescent lamps. When the angle of the optical axis of the sensor (light receiver) and the strong light source cannot be changed, the sensor can be surrounded by ...

Pressure sensor influencing measurement results factor – Ottonix Pressure sensor influencing measurement results factor – Ottonix

Pressure is an important parameter in pneumatic, fluid or other measurements, so pressure sensors have been widely used in various experimental measurements, product testing, and automatic control systems, and the stability of the product is a major consideration when purchasing pressure sensors. ...

The difference between Autotonics switching power supply and module power supply The difference between Autotonics switching power supply and module power supply

Modular power supplies are power supplies that can be mounted directly on a printed circuit board and feature power supply to application-specific integrated circuits (ASICs), digital signal processors (DSPs), microprocessors, memory, field-programmable gate arrays (FPGAs), and other digital or analog loads. One...

Advantages of digital load cells – Autonex Advantages of digital load cells – Autonex

1. The transmission interval of the digital load cell is long, the communication speed is fast, and the anti-cheating effect is remarkable; The output signal of the traditional analog load cell is small, generally millivolt level, and the signal is still lost due to the damage of the cable resistance during the transmission process, and it is also very simple to be affected by the surrounding environment.

The difference between switching power supply and module power supply – Autonix The difference between switching power supply and module power supply – Autonix

Modular power supplies are power supplies that can be mounted directly on a printed circuit board and feature power supply to application-specific integrated circuits (ASICs), digital signal processors (DSPs), microprocessors, memories, field-programmable gate arrays (FPGAs), and other digital or analog loads.

There are several measurements related to the Autonicus photoelectric switch There are several measurements related to the Autonicus photoelectric switch

1. Measurement of action interval; When the action piece approaches the sensing surface of the switch from the front, the interval between the action of the switch is the interval between the action of the switch, and the measured data should be within the parameters of the product. 2. The Liberator ...

Precautions during the use of the Autonex proximity switch Precautions during the use of the Autonex proximity switch

1) The detected object should not touch the proximity switch, so as not to damage the proximity switch due to friction and bumping; 2) Pull the lead wire of the switch by hand will damage the switch close, and it is best to fix the lead wire with a line card at 10 cm away from the switch when the device is installed.

Position sensor key term – Ottonix Position sensor key term – Ottonix

Incremental sensors Only bearing change information is provided so that the practice bearing is unknown at startup. Each time the index is made/marks the zero or zero bit of the signaling community. Detected in the homing procedure. Regarding the commutation of brushless motors, motors generally have three magnetic Hall sensors, which are ...

Precautions for the use of Autotonics safety light curtains Precautions for the use of Autotonics safety light curtains

Cover the safety light curtain with your hands and observe whether the indicator light conversion is normal. During the use of the punch photoelectric protection device, the orientation of the photoelectric protection device shall not be changed at will. In the protection zone, the light curtain should be blocked by hand, and the machine should be able to stop the operation immediately. ...

Gas Sensor Failure Analysis – Ottonix Gas Sensor Failure Analysis – Ottonix

A gas sensor is a converter that converts the volume fraction of a gas into an electrical signal. We will inevitably encounter some problems when using gas sensors, and we have analyzed them as follows: 1. How long does it take for the gas sensor to be used and then calibrated again: the initial calibration ...

Advantages of digital torque sensors – Autotonics Advantages of digital torque sensors – Autotonics

In the rotary power system, the most frequently involved parameter: rotational torque, in order to detect the rotational torque, the traditional use of torsion angle phase difference sensors. The more mature detection method of torque testing is strain electrical testing skills. It has high precision, fast frequency response, good reliability, long life, etc.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top