Introduction to Autonix pressure sensor technology
1. Capacitive Capacitive pressure sensors are usually cleaned by a large number of OEM professional applications, testing the capacitance change between two surfaces, so that these sensors can sense the extreme pressure and vacuum level. In our typical sensor setup, the compact outer gram contains two metal exteriors, ...
|
|
Otonic photoswitch determination
1. Measurement of action interval; When the action piece approaches the sensing surface of the switch from the front, the interval between the action of the switch is the interval between the action of the switch, and the measured data should be within the parameters of the product.
2. The interval between exonerations ...
|
|
Key points of visual inspection of electric motors - Ottonix
Key 1: Whether the speed of the motor is normal, whether there is speed jitter and stalled rotation (you can check it with a tachometer).
The key is whether the anchor bolts of the motor are loose, whether the root is defective, and whether there are debris around.
The key is three, whether the housing and coupling of the motor are defective, ...
|
|
Pressure sensor identification items and verification methods
1. Look at it visually.
2. Verify the sealing and preloading of the system.
3. The pressure sensor is equipped on the pressure standard equipment, including the pressurization (or vacuuming) equipment, and the pressure standard equipment with liquid as the pressure transmission medium should sweep the air in the pipeline.
4 pressure sensors, ...
|
|
Precautions for the use of fiber optic sensors
SET button, which can be used to set the sensitivity. The basic principle of the sensor is to sense the refractive index of different media through a fiber optic probe, so as to obtain a digital signal, display it on the screen, and send the switching value by comparing the magnitude of the displayed value and the set sensitivity value. Indicator light when the sensor ...
|
|
Introduction to the Autonex differential pressure flow meter
The differential pressure flowmeter calculates the flow rate according to the differential pressure generated by the flow test piece installed in the pipeline, the known fluid conditions, and the size of the test piece and the pipeline.
The differential pressure flowmeter consists of a primary device (test piece) and a secondary device (differential pressure conversion and flow display) ...
|
|
Autonex 3-point light cross-mesh photoelectric sensor
The Ottonix sensor BWC series has selected a 3-point light cross-network detection method to reduce the detection blind spot to the maximum limit, realize the world's leading detection characteristics, and effectively prevent problems that may be caused by direct sunlight, etc., and the detection is more stable.
Up to 100 international cutting-edge ...
|
|
Advantages of digital torque sensors – Autotonics
In the rotary power system, the most frequently involved parameter: rotational torque, in order to detect the rotational torque, the traditional use of torsion angle phase difference sensors. The more mature detection method of torque testing is strain electrical testing skills. It has high precision, fast frequency response, good reliability, long life, etc.
|
|
Pressure Sensor Fault Detection – Ottonix
First, the first component is blocked or the form of the device is wrong, and the pressure point is unreasonable, so we often emphasize that the device must be the correct device, once it is installed wrongly, or it is not well installed, it will bury endless hidden dangers for the back. What are the primary components? Orifice plates, remote transmission measuring joints, etc.
|
|
Torque Transducer Classification – Ottonix
Torque sensor is the necessary device in some products, mainly used to measure the speed and point of view, but different types of sensors, the use of methods and effects are different, so what are the classifications of torque sensors?
...
|
|
The difference between switching power supply and module power supply – Autonix
Modular power supplies are power supplies that can be mounted directly on a printed circuit board and feature power supply to application-specific integrated circuits (ASICs), digital signal processors (DSPs), microprocessors, memories, field-programmable gate arrays (FPGAs), and other digital or analog loads.
|
|
Autonex SFC series safety controllers
The SFC series of safety controllers can be used with safety input products (switches, sensors, etc.) and satisfies the self-diagnosis function and safety integrity required by safety standards. In addition, the slim design saves space in the installation and allows for the use of screwed/screwless pushes for wiring connections.
|
|
Precautions for the use of photoelectric sensors
First, the selection of its primary consideration for the selection of three points: how wide the groove width should be; resolution (slit width); Fixation
1. The width of the slot, the detection object needs to pass through the slot of the slot-type optocoupler to block the infrared light, so the slot width of the photoelectric sensor should be wider than the detection object, and there should be a certain ...
|
|
Autonicx was selected as one of the "Top 300 World-Class Enterprises" in Korea Industrial Control
With the strong support of our customers, Autoniks was selected as one of the "Top 300 World-Class" enterprises by the Korea government for the first time in the industrial control industry.
The Korea government's selection of "Top 300 World-Class Enterprises" is an increase in the number of choices ...
|
|
Autonex proximity switch PRD/PRDW series
Autonex cylindrical remote proximity switch PRD/PRDW series, the selection of self-developed special IC, with the highest international noise immunity level, high echo frequency, low leakage current and residual voltage, the detection interval is 1.5-2 times of the original product, close to the switch and the cable connection part of the selection of strong ...
|
|
Calibration process of a tension transducer – Autotonics
1. Plug in the force sensor you want to calibrate, such as a force sensor with a range of 50kg, and select a force sensor channel on the left;
2. Enter the range of the sensor in the "range" input box, such as "50" kg;
3. Enter the zero value force of the sensor in the "zero value" input box, generally enter ...
|
|
Sensors commonly used in industrial robots
In the field of industrial automation, machines need sensors to provide the necessary information to perform the relevant operations correctly. Robots are now using a number of sensors to improve their adaptability. For example, there are many cobots that integrate torque sensors and cameras to ensure that they are equipped with torque sensors and cameras during operation.
|
|
Causes and solutions for overheating or burning of AC contactor coils
Reasons: 1. The polar surface of the communication core is uneven or the demagnetization air gap is too large;
2. The double coil of DC operation derived from the communication contactor is overheated due to the fact that the normally closed interlocking contact is not released by welding;
3. The frequency of operation is too high;
4. Poor coil manufacturing or due to mechanical damage, absolute ...
|
|
Rapid detection method for air conditioner thermostat – Ottonix
When the air conditioner cannot operate normally, in addition to checking the starting relay, overheating, overcurrent protector and capacitor of the compressor, it is also necessary to check the main control selection switch of the air conditioner thermostat, which is a very important control protection and actuator component in the electrical control system. Here are a few common types of air ...
|
|
Load cell quality selection – Autonex
1. Observe whether the outside of the load cell is deformed or cracked. If there is any damage, please contact the manufacturer immediately.
2. Find the connection end of the sensor in the weighing controller, and measure the connection circuit of the sensor. The general excitation voltage (between EXC+ and EXC-) is 5-10V, and the output ...
|