Maintenance method of Yaskawa inverter

Create Date: 2024-8-30 12:03:23|Source: YASKAWA/Yaskawa

Checkpoints for daily use

When inspecting and maintaining the inverter on a daily basis, it is necessary to check the temperature and humidity around you. Excessive temperature will lead to overheating alarms, and in serious cases, it may also lead to damage to some components or short circuits in the circuit. If the humidity in the air is too high, some devices will cause an internal short circuit in the inverter after being removed from the water vapor.

When inspecting, it is also necessary to pay attention to the inspection of the cooling system and air duct. Whether the cooling system is working normally, whether the air duct is blocked by dust, etc. It is a point that needs to be paid attention to in daily inspections. In order to avoid a small problem, the overall problem will be caused by a greater cost of maintenance.

Regular maintenance matters

For regular maintenance, pay attention to cleaning the dust inside the air duct, filter and inverter. Check whether the parts used for fixing, etc., are loose. Whether conductors and insulators are corroded. It is also necessary to check whether the waveform of the circuit is a sine wave. We mainly recommend regular maintenance of the inverter, which should be carried out once a year.

Spare parts replacement

The components of the inverter are complex and diverse, and some parts may be aged or even damaged after a period of use. These problem parts, if not replaced in time, may cause the inverter to malfunction and affect the normal use. Some of these components should also be replaced regularly, including fans and capacitors for cooling. The performance of these two components will deteriorate in long-term uninterrupted work, so they need to be replaced regularly to ensure normal operation and performance.
Maintenance method of Yaskawa inverter

More on that
Midea's holding of Kuka eventually led to Midea's Yaskawa going the other way Midea's holding of Kuka eventually led to Midea's Yaskawa going the other way

Not long ago, it was found from the national enterprise information management system that the joint venture industrial manipulator enterprise founded by Midea and Yaskawa Electric announced the record cancellation/announcement information on April 12, and had already established a liquidation team to accept debt applications. The joint venture is a joint venture in Guangdong ...

Yaskawa servo drive parameters Yaskawa servo drive parameters

PN000 function selection N.0010 (setting value) 0th position: set the direction of rotation of the motor; Set "1" to change the rotation of the motor in reverse. 1st position: Set the control mode to: "1" position control mode. PN200 Command Pulse Input Mode Function Selection N.0101 (Set Value) "1" Positive ...

Yaskawa servo drive fault code Yaskawa servo drive fault code

Yaskawa servo drives are used to control servo motors, which are similar to AC motors and are part of the servo system. The servo drive takes the digital signal processor as the control core, which can realize more complex control algorithms and realize digitalization, networking and intelligence. The present invention adopts the wisdom ...

Yaskawa Robotics - the main technology of the robot control system Yaskawa Robotics - the main technology of the robot control system

(1) Open modular control system architecture: using distributed CPU computer structure, divided into robot controller (RC), motion controller (MC), optoelectronic isolation I/O control board, sensor processing board and programming teaching box, etc. The Robot Controller (RC) and the programmed teaching pendant are connected via a string...

What is the fault of Yaskawa servo drive alarm code 710 and how to solve it What is the fault of Yaskawa servo drive alarm code 710 and how to solve it

Yaskawa servo drive alarm code 710 is overload (large load), the motor is overloaded for a few seconds to tens of seconds. Solution(s): 1. Change the mechanism, or the acceleration and deceleration mechanism. 2. Change the motor. 3. Exclusion order: 1) The load is really too large 2) ...

Yaskawa robot maintenance and regular inspection Yaskawa robot maintenance and regular inspection

For the maintenance of Yaskawa robots, maintenance should be carried out before and after each use, check whether there is damage to the outside of the robot, and check whether the robot movement is abnormal. Then be sure to check the battery frequently, and if you find that the battery is not working, you should replace it as soon as possible. The gearbox should be checked frequently to see if there is ...

Advantages of Yaskawa inverter A1000 Advantages of Yaskawa inverter A1000

Excellent motor drive function Advanced motor drive skills All motors can be controlled – whether they are driving induction motors or synchronous motors (IPM motors/SPM motors) – with high utility current vectoring. Inverters for induction and synchronous motors ...

The phenomenon that occurs when the various parts of Yaskawa inverter are damaged The phenomenon that occurs when the various parts of Yaskawa inverter are damaged

1) Main control board When the main control board is damaged, the operation panel may not be displayed, the motor may be sluggish, and there will be jitter during the operation, or there may be no action. External instructions are not acceptable, the multifunction input signal is not displayed (there is no change in U1-10). 2) Driver board ...

Yaskawa Servo Drive FAQ (1-9) Yaskawa Servo Drive FAQ (1-9)

[1] Yaskawa 5 series 1KW drive on telegram 030 what is the reason? When you power on, it will display 030, check the manual to explain: the main circuit is abnormal in various detection data, and there is no problem with the main circuit module after checking. Is there a motherboard that can be swapped to try, if not...

A robot village opened to commemorate the 100th anniversary of Yaskawa Electric A robot village opened to commemorate the 100th anniversary of Yaskawa Electric

Japan's Yaskawa Electric famously created the first all-electric industrial robot, Motoman, in 1977, headquartered in the city of Kita-Kyushu, since its establishment in 1915, has gone from being called "Yaskawa Electric Japan as an automobile manufacturer", "Yaskawa Electric Automation Company of Japan" to "...

The causes and treatment methods of the fault of the SC of Yaskawa inverter The causes and treatment methods of the fault of the SC of Yaskawa inverter

1. The inverter shows that SC refers to the drive fault. 2. Cause of failure: 1. The output side of the inverter is interphase or short circuit to the ground. 2. The inverter module is damaged. 3. Handling method: 1. Remove the load, power on normally and turn on the machine, check if there is a three-phase ...

Product classification of Yaskawa servo motors Product classification of Yaskawa servo motors

Yaskawa Electric is a professional manufacturer in the field of motion control, is the first company in Japan to do servo motors, its products are known for stable and fast, cost-effective, is the world's largest sales, the most used servo brand. In China, Yaskawa Servo has occupied the largest market for many years ...

Yaskawa servo drive fault code and handling method Yaskawa servo drive fault code and handling method

1. If the fault code on the Yaskawa servo drive is UV1, it means that the low voltage of the main circuit is lower than the low voltage standard of 200V, at this time, we need to check whether there is a problem with the wiring of the power supply; 2. If the ...

Yaskawa Robotics - technical performance characteristics of dresspacks for industrial robots Yaskawa Robotics - technical performance characteristics of dresspacks for industrial robots

1. Technical performance characteristics of industrial robot dresspack - intelligence The reason why the intelligent type is placed at the back of the Z is because compared with the mainstream demand for robot dresspacks in the market (that is, strong, fast, and accurate), it is not the most urgent for the time being. This also reflects the ...

Yaskawa SGD7S-120A00B202 servo driver alarm fault recovery Yaskawa SGD7S-120A00B202 servo driver alarm fault recovery

1. First, confirm the alarm code. The alarm code is different for each servo drive, so you need to consult the corresponding equipment manual or contact the manufacturer for a specific list of alarm codes. 2. Determine the cause of the fault according to the alarm code. Different alarm codes correspond to different fault types, which can be ...

Yaskawa inverter installation precautions Yaskawa inverter installation precautions

Precautions for installing Yaskawa inverter   Do not turn on the power supply during wiring operations, otherwise there will be a risk of electric shock. In order to prevent electric shock, please do not operate in the state of removing the inverter cover, otherwise there will be a risk of electric shock. Be sure to ground the ground terminal on the motor side ...

Yaskawa Servo Motor – The difference between a stepper motor controller and a servo motor controller Yaskawa Servo Motor – The difference between a stepper motor controller and a servo motor controller

First, the working principle is different Stepper motor controller: It is an electronic product that can send out a uniform pulse signal, and the signal it sends out enters the stepper motor driver, which will be converted by the driver into a strong current signal required by the stepper motor to drive the stepper motor to run. Stepping ...

Yaskawa Electric restores three plants in Japan on the premise of safety Yaskawa Electric restores three plants in Japan on the premise of safety

Yaskawa Electric recently announced that its soft starter processing plant in Shanghai has resumed production since February 18. So far, the three processing plants of this Japanese-funded processing and manufacturing company in China have been fully opened. Last week, Yaskawa Electric in China processed two other ...

Yaskawa inverter - precautions for high-voltage inverter Yaskawa inverter - precautions for high-voltage inverter

1. Carefully monitor and record the display parameters on the man-machine interface of the inverter, and reflect the abnormality immediately 2. Carefully monitor and record the ambient temperature of the inverter room, and the ambient temperature should be between -5 °C and 40 °C. The temperature rise of the phase-shifting transformer should not exceed 130°C 3. Summer ...

Inverter wiring method Inverter wiring method

First, the wiring of the main circuit 1. The power supply should be connected to the R, S, and T terminals at the input end of the inverter, and must not be connected to the output terminal (U, V, W) of the inverter, otherwise the inverter will be damaged. After wiring, the fragmented wires must be cleaned, and the fragmented wires may cause abnormalities. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top