The difference between Schneider verification and calibration

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

(1) The intent is different

The intent of the verification is to carry out a mandatory comprehensive appraisal of the measuring equipment. This comprehensive identification of areas attributed to the value of the same value is a top-down process of value transfer. The verification shall identify whether the measuring equipment meets the specified requirements.

This requirement is to measure the size of the error specified in the equipment verification regulations. After verification, it is determined whether the error scale of the measuring equipment is within the specified error scale.

The intention of calibration is to identify the indication error of the measurement equipment according to the measurement specification, ensure the accuracy of the measurement value, and attribute it to a set of operations that trace the value from the bottom up.

The identification of such indication errors should be made in accordance with the calibration procedures arranged, carried out according to the calibration cycle, and the calibration records and calibration marks should be made.

(2) The goals are different

The target of verification is the measurement equipment for compulsory verification clearly stipulated in China's metrology law. The objectives of the verification are mainly three categories of measuring equipment:

1. Measurement benchmark (including world measurement benchmark and ** measurement benchmark).

2. Metrological specifications.

3. The measurement law stipulates that 59 kinds of measuring tools are included in the compulsory inspection catalog.

The goal of calibration is to classify measuring equipment outside of the mandatory verification. China's non-mandatory verification of measuring equipment, mainly refers to a large number of measuring tools used in the process of production and service provision, including the measurement equipment used in purchase inspection, process inspection and final product inspection.

                            The difference between Schneider verification and calibration

(3) Different in nature

The verification is a mandatory legal act and belongs to the field of legal measurement and management.

Calibration is not mandatory, but is a voluntary traceability arrangement.

(4) Depending on the difference

The primary basis for verification is the "** Metrological Verification Regulations" (JJG), which is a statutory technical document that must be adhered to for the verification of measuring equipment. These regulations are classified as metrological regulatory documents, and the arrangements do not have the authority to draw up, and it is necessary to be drawn up by the approved authorized metrology department.

The primary basis for calibration is to arrange the "Calibration Specification" drawn up according to the actual needs, or in accordance with the requirements of the "**Metrology Technical Specification" (JJF).

(5) The methods are different

It is necessary to carry out the verification to the qualified metrology department or the legally authorized unit. According to the current situation in China, most production and service arrangements do not have the qualification of verification, and only a small number of large-scale arrangements or professional metrology verification parts have this qualification.

The method of calibration can be carried out by arranging self-school, external school, or a combination of self-school and external school.

Under the condition of arrangement, the self-calibration method can be used to calibrate the measuring equipment, and then save a lot of money.

(6) The cycle is different

It is necessary to carry out the verification cycle in accordance with the provisions of the "Verification Regulations", and the arrangement cannot be confirmed by itself. The content of the verification cycle is subject to mandatory constraints.

The calibration interval is determined by the arrangement according to the needs of the measuring equipment used. It can be calibrated at a timed time, or at irregular intervals, or calibrated prior to use.

(7) The content is different

The content of the verification is a comprehensive appraisal of the measuring equipment, which requires a more comprehensive one, in addition to including all the contents of the calibration, it is also necessary to verify the relevant items.

The content and items of calibration only identify the indication error of the measurement equipment to ensure the accuracy of the measurement value.

(8) The conclusions are different

It is necessary to give a judgment of whether the measurement equipment is qualified or unqualified according to the scale of the measurement error specified in the "Verification Regulations". The scale of the error beyond the specified value of the "Verification Regulations" is unqualified, and it is qualified within the specified scale of the error of the value. The result of the verification is to give the "Certificate of Verification".

The conclusion of calibration only identifies the error of the measurement device, ensures the accuracy of the measurement, and does not require a pass or fail determination. The results of the calibration can be given as a "Calibration Certificate" or "Calibration Report".

(9) The legal effect is different

The conclusion of the verification has legal effect, which can be used as the legal basis for the verification of measuring appliances or measuring equipment, and the "Certificate of Conformity" is attributed to the technical documents with legal effect.

The conclusion of the calibration has no legal effect, and the "calibration certificate" given only indicates the error of the value and is attributed to a technical document.

From the above, it can be seen that the verification, calibration, and calibration are not completely independent, and the calibration process is included in the verification and calibration, and only the question of whether to give the calibration results is given.

More on that
Common maintenance problems for Schneider drives Common maintenance problems for Schneider drives

1. Why is the inverter used for fan and pump loads to save energy? According to the basic law of fluid mechanics, it can be seen that the fan pump load is a typical square rotation load, and its primary feature is that the speed n has the following relationship with the torque T and the load power P: T∝n2, P∝n3. ...

Pay attention to the problem when using UPS power supply - Schneider Pay attention to the problem when using UPS power supply - Schneider

1. The parameters set in the host cannot be changed at will during use. In particular, the parameters of the battery pack will directly affect the service life. With the change of ambient temperature, the float charge voltage should be adjusted accordingly. Generally, 25 °C is the standard, and when the ambient temperature rises or falls by 1 °C, the float charge ...

Frequency converter control motor leakage solution - Schneider Frequency converter control motor leakage solution - Schneider

Because the current at the input and output ends of the inverter contains high-frequency components, the leakage current formed by the high-frequency components when the inverter is driven is greater than that when the grid power supply is supplied. Because there are many varieties of circuit breakers, in some cases, even the inverter wires and motors ...

Schneider Thermal Relay Model Meaning Schneider Thermal Relay Model Meaning

The function of the thermal relay is mainly used to carry out overload maintenance on the asynchronous motor, and his operating principle is that after the overload current passes through the thermal element, the bimetal sheet is heated and twisted to advance the action organization to drive the contact action, so as to disconnect the motor control circuit to realize the motor power-off thermal relay ...

Common analysis method for electrical control line faults - Schneider Common analysis method for electrical control line faults - Schneider

1) Survey and research method. The investigation and research method is to understand the obvious problem phenomena through "seeing", "listening", "smelling", "touching" and "asking"; After visiting the operator, understand the cause of the failure; A common way to help find the fault point after asking others or consulting information ...

Analysis of 10 reasons for frequent tripping of Schneider leakage switches Analysis of 10 reasons for frequent tripping of Schneider leakage switches

1. Defective device If the lead wire of each pile head is not firmly connected and loosened for a long time, it will cause the pile to heat and oxidize, burn out the outer insulation of the wire, and announce sparks and burnt smell, resulting in undervoltage of the line and air switch action. 2. Leakage switch with ...

The way the frequency of the inverter is given – Schneider The way the frequency of the inverter is given – Schneider

The given frequency refers to the frequency at which the inverter is set to operate, and the given frequency can be given by the operation panel or by the external method, during which the external method is divided into voltage and current. First, the operation panel is given a frequency ...

Schneider instrumentation winter insulation measures Schneider instrumentation winter insulation measures

The methods adopted usually are: selection, thermal insulation and heat tracing, protection (point inspection, sewage discharge) and so on. Selection method Choose the appearance of the type with insulation equipment. According to the category and use of the appearance and the geographical location of the proposed equipment, the insulation and antifreeze requirements of the appearance are proposed, and then submitted to the manufacturer for processing. ...

The role of Schneider thermal relays The role of Schneider thermal relays

The effect of the thermal relay is mainly used to carry out overload maintenance on the asynchronous motor, his operating principle is that after the overload current passes through the thermal element, the bimetal sheet is heated and bent to advance the action mechanism to drive the contact action, so as to disconnect the motor control circuit to complete the motor power-off thermal relay ...

Schneider ATV312 inverter failure Schneider ATV312 inverter failure

1. OLF is motor overload. Possible reasons: 1. Triggered by high motor current. 2. The value of the [cold stator resistance] (rSC) parameter is wrong. Corrective measures: 1. Check the [Motor Thermal Current] (ItH) setting of the motor thermal maintenance function and check the motor load. Wait...

Two of Schneider's low-voltage power distribution products won the Germany Red Dot Award Two of Schneider's low-voltage power distribution products won the Germany Red Dot Award

Beijing, China, April 6, 2022 – Recently, the list of "Red Dot Planning Awards", known as one of the world's three cutting-edge industrial planning awards, was grandly announced in Germany.

Schneider ATV71 selection and letter meaning Schneider ATV71 selection and letter meaning

The type of Schneider inverter generally reflects the rated voltage, rated power, and load requirements of the inverter (heavy or light load). Here are two examples: Example 1: Schneider Inverter Type: ATV71HD11N ...

Schneider appeared at the 5th China Power Distribution Technology Summit Forum Schneider appeared at the 5th China Power Distribution Technology Summit Forum

Beijing, China, September 14, 2020 – Today, the 5th China Power Distribution Technology Summit Forum 2021, held by China Electric Power Research Institute Co., Ltd. and the Science and Technology Development Service Center of China Electric Power Council, opened in Beijing. The theme of this forum is "Supporting the Strategic Policy of Carbon Peaking and Carbon Neutrality, Building a ...

Frequency converters and their control – Schneider Frequency converters and their control – Schneider

AC inverter is the result of the high development of microcomputer and modern power electronics technology. The microcomputer is the center of the inverter, and the power electronics form the main circuit of the inverter. As we all know, the frequency of communication electricity sent from power plants is stable and constant, in our country it is 50 weeks per second ...

The difference between Schneider UPS and EPS power supply The difference between Schneider UPS and EPS power supply

1. Different safety standards UPS is mainly used to protect users' equipment or business from economic loss, and its product technical certification mainly includes Thiel certification, CQC certification, etc. The development of EPS power supply stems from the sudden failure of the power grid, in order to ensure the power safety and fire linkage needs, it can be supplied immediately.

The meaning of the inching of Schneider inverter The meaning of the inching of Schneider inverter

The inch movement in Schneider inverter means that the control signal can drive the motor intermittently according to the certain rules, and the motor acts in strict accordance with the dynamic and stop instructions of the control signal, and the motor does not roll by inertia during the shutdown. It's like moving an inch and then stopping. The full name of Schneider inverter is "...

Frequency characteristics of frequency converters – Schneider Frequency characteristics of frequency converters – Schneider

a. Output frequency scale. The output frequency scale that can be controlled by the general inverter, the lowest starting frequency is generally 0.1Hz, and the highest frequency varies according to the functional indicators of the inverter, generally 400Hz, and some models are 650Hz. No matter how high the output frequency is, it depends on the scale of the high-frequency inverter. ...

Schneider Electric inverter applications Schneider Electric inverter applications

Schneider inverter, the full name of "Schneider communication inverter governor", is a well-known inverter brand developed, manufactured and sold by Schneider Electric Group in France. It is mainly used to control and regulate the speed of three-phase communication asynchronous motor, with its stable performance, rich combination functions, outstanding ...

Inverter maintenance mantra method - Schneider Inverter maintenance mantra method - Schneider

Don't worry about the damage of the frequency conversion, disassemble the machine after the discharge; It is indispensable to ask for a diagnosis and clarify the problem at the beginning of the test; Input and output PN junction, three-phase balance and then unshelling; Look at the nameplate before powering on, the wrong voltage will blow up; The bus has no electricity to see that it is safe, and the rectifier filter is wrong ...

Schneider Multi9 Series C120 FAQs Schneider Multi9 Series C120 FAQs

1. What are the characteristic curves of Schneider Multi9 series C120L? A: C/D curve. 2. What is the rated current level of Schneider Multi9 series C120? A: 63A, 80A, 100A, 125A. 3. Shi ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top