The role of Schneider thermal relays

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

The effect of the thermal relay is mainly used to carry out overload maintenance on the asynchronous motor, and his operating principle is that after the overload current passes through the thermal element, the bimetal sheet is heated and bent to advance the action mechanism to drive the contact action, so as to disconnect the motor control circuit to complete the motor power-off thermal relay parking, and play the effect of overload maintenance. In view of the fact that the heat transfer needs to be long during the heating and bending of the bimetal sheet, therefore, the thermal relay cannot be used for short-circuit maintenance, but only for overload maintenance, and the symbol of the thermal relay is FR.

  ​                         The role of Schneider thermal relays

Since the thermal relay is activated by heat, the thermal inertia is large, so even if the current through the heating element exceeds the setting current several times in a short time, the thermal relay will not act immediately. Only in this way, when the motor starts, the thermal relay will not act due to the large starting current, otherwise the motor will not be able to start. On the other hand, if the current exceeds the setting current, it will not be much, but it will also operate after a long time. It can be seen that the effect of thermal relay and fuse is different, thermal relay can only be used for overload maintenance and can not be used for short-circuit maintenance, while fuse can only be used for short-circuit maintenance but not overload maintenance. In a well-developed control circuit, especially in a motor with a large capacity, both types of maintenance should be available.

More on that
Instrumentation mechanical equipment system - Schneider Instrumentation mechanical equipment system - Schneider

1. Power system: The wire and cable products selected in the power system mainly include overhead bare wires, busbars (busbars), power cables (plastic cables, oil-paper power cables (fundamentally replaced by plastic power cables), rubber cables, overhead insulated cables), branch cables (replacing part of the busbars), ...

Inverter braking resistor selection – Schneider Inverter braking resistor selection – Schneider

In the process of fast parking, because of the inertia, a lot of regenerative electric energy will occur, which will directly act on the intermediate DC part of the inverter, and if this part of the electric energy is not consumed, the inverter will be faulty or the inverter will be damaged. The braking resistor is used to dissipate this part of the electrical energy. ...

Schneider diode selection experience and substitution method Schneider diode selection experience and substitution method

1. Selection of detection diode Point-contact germanium diodes are generally used for detection diodes, such as 2AP series. When selecting, the detection diode with high operating frequency, small reverse current and large forward current should be selected according to the specific requirements of the circuit. Although the detection and rectification of ...

Instrumentation anti-interference measures - Schneider Instrumentation anti-interference measures - Schneider

The interference encountered by sensors and instruments in the field operation is varied, and the specific situation is analyzed on a case-by-case basis, and the principle of anti-interference is to adopt different methods for different disturbances. This flexible and mobile strategy is undoubtedly opposed to universality, and the way to deal with it is to choose a modular approach, except for ...

Features of Schneider explosion-proof inverter boxes Features of Schneider explosion-proof inverter boxes

1. Aluminum alloy shell or steel plate welding, plastic spraying on the surface; 2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies; ​ 3. It mainly regulates the general three-phase difference by changing its output frequency.

Schneider TRSS telemetry system solution Schneider TRSS telemetry system solution

Schneider Electric provides safe, reliable, end-to-end telemetry solutions to help you meet the challenges of long-distance operations. With an outstanding reputation in the fields of appearance, manipulation and data collection, wireless communications, IT, and other industries and common sense, Schneider Electric telemetry system solutions can help ...

The difference between Schneider UPS and EPS power supply The difference between Schneider UPS and EPS power supply

1. Different safety standards UPS is mainly used to protect users' equipment or business from economic loss, and its product technical certification mainly includes Thiel certification, CQC certification, etc. The development of EPS power supply stems from the sudden failure of the power grid, in order to ensure the power safety and fire linkage needs, it can be supplied immediately.

Schneider Electric has announced the launch of its Pacific Foundation Schneider Electric has announced the launch of its Pacific Foundation

Schneider Electric has announced the launch of its Pacific Foundation, which will provide financial and advisory support to charitable foundations in the Pacific region to address fundamental human rights issues of access to energy. Four foundations were selected as the Foundation's initial recipients.

Analysis of the causes of Schneider touch screen touch deviation Analysis of the causes of Schneider touch screen touch deviation

(1) Fault--: Contact error Phenomenon 1: The direction of the finger does not coincide with the mouse arrow. Reason 1: After installing the driver, there is no vertical contact with the bullseye center when correcting the bearing. Solution 1: Re-align the bearing. Phenomenon 2: Some districts ...

Four-pole switches need a scene – Schneider Four-pole switches need a scene – Schneider

(1) It is necessary to choose a four-pole switch: For the sake of repair safety: in the TT grounding system, the total equipotential bonding is done on the user side, but because the total equipotential bonding at this moment does not include the neutral wire, the line fault (for example: a phase wire grounding) occurs on the grounding electrode on the power supply side.

Analysis of the reasons why the contact of Schneider contactor is not reliable Analysis of the reasons why the contact of Schneider contactor is not reliable

The unreliable contact touch will increase the touch resistance between the dynamic and static contacts, resulting in the high temperature of the touch surface, making the surface touch become a point touch, and even showing a non-conduction phenomenon. The reasons for this failure are: (1) There are ...

Schneider thermal relay selection method Schneider thermal relay selection method

1. In principle, the ampere-second characteristics of the Schneider thermal relay should be as close as possible to or even coincide with the overload characteristics of the motor, or under the overload characteristics of the motor, and at the same time, the Schneider thermal relay should not be affected (not acting) at the moment of short-term overload and start of the motor. ...

About the characteristics of Schneider explosion-proof inverter cabinet About the characteristics of Schneider explosion-proof inverter cabinet

1. Aluminum alloy shell or steel plate welding, surface spraying; 2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies; 3. It mainly regulates ordinary three-phase by changing its output frequency ...

Schneider inverter fault repair Schneider inverter fault repair

Inverter communication failure · Fault code: SLF Fault title: Inverter communication problem. Cause of the failure: Communication abort on the inverter communication bus. The way to deal with the fault: check whether the communication connection is normal: check the communication timeout setting: check the ...

Selection and control of the inverter installation - Schneider Selection and control of the inverter installation - Schneider

Frequency converters are widely used equipment in modern industry. If you want to complete the functions of soft stop, soft start, stepless speed regulation or special requirements for speed rise and fall, you need the more advanced speed control equipment in modern asynchronous motors - frequency converters. The main circuit of the equipment is selected to communicate - DC - communication ...

Inverter fault repair - Schneider Inverter fault repair - Schneider

To repair the output board driven by the inverter, we must first investigate whether the components on the PCB board are burned out, replace them first, and then analyze what causes the burned out and deal with this problem. And then...

Schneider soft starter fault alarm maintenance method Schneider soft starter fault alarm maintenance method

1. Question-F 05 (frequency error): This problem is caused by a problem with the soft starter processing the internal power signal, which is causing errors in the power supply frequency. This situation needs to be handled by the company's product development software design engineer. Mainly start the power supply circuit design ...

Schneider Compact NSX series molded case circuit breaker selection recommendation Schneider Compact NSX series molded case circuit breaker selection recommendation

The molded case circuit breaker is an important part of the maintenance of the low-voltage distribution system and the motor, and maintains the safety of the distribution system and electrical equipment. As an important application scenario of molded case circuit breakers, these key occupations of new infrastructure such as new energy and telecommunications have extremely important equipment performance, stability and adaptability.

Schneider relay model introduction Schneider relay model introduction

RM4 Series Control Relay (Three-phase Power Control) RM4 series voltage steerable relays RM4 current operated relay RM4 level control relay RM17 three-phase power controller RM35 3-phase power control relay RM17 Voltage Steerable Relay ...

Schneider drives copy replication parameters Schneider drives copy replication parameters

1. Copy and copy through the Chinese panel. Older inverters, if they support Chinese panels, such as ATV71, ATV61, etc., support VW3A1101 panels, they can use the proprietary 'open/save as' parameter on the panel to copy and copy, and the newer ATV610, ATV630, ATV930, ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top