Schneider Electric inverter applications

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

Schneider inverter, the full name of "Schneider communication inverter governor", is a well-known inverter brand developed, manufactured and sold by Schneider Electric Group in France. It is mainly used to control and regulate the speed of three-phase communication asynchronous motors, and occupies an important position in the inverter market with its stable performance, rich combination functions, outstanding dynamic characteristics, super overload ability and incomparable flexibility. It is widely used in various industrial fields, especially in elevators, textiles, machine tools, lifting and transportation, and ports and other industries.

                              Schneider Electric inverter applications

ATV312 performance depiction

1. Built-in Modubs and CANopen protocols, providing CANopen daisy chain, Profibus DP, and DeviceNet;

2. Brand new user interface, support Chinese operation panel;

3. Provide simple and multi-function downloader for convenient parameter configuration;

4. All coatings, accustomed to various harsh environments, the top of the inverter is supplied with IP41 protection level;

5. Modular planning of detachable terminals, cost-saving and convenient installation;

6. The highest withstand voltage of the same level, the standard voltage fluctuation is -15%-10%, and the promised voltage drops by 50%;

7. M2 and N4 built-in EMC filter;

8. Widest working temperature, -10°C - +50 °C without degrading, up to +60 °C;

9. Super output characteristics, built-in braking unit, over torque to 170%-200%;

10. Side-by-side device, space-saving.

ATV312 advantages:

1. More communication compatibility and more friendly human-computer interaction;

2. Abundant use functions, excellent environmental habits.

ATV312 range of use

The ATV312 drives are versatile for many common uses, including:

1. Material handling (small conveyors, cranes, etc.)

2. Packaging machines (small bag making machines, labeling machines, etc.)

3. General machines (machine tools, textile machinery, etc.)

4. Pumps, compressors, fans

More on that
Schneider Multi9 Series C120L Problem Schneider Multi9 Series C120L Problem

1. What are the characteristic curves of Schneider Multi9 series C120L? C/D curves. 2. What is the rated current level of Schneider Multi9 series C120? 63A、80A、100A、125A。 3. What is the weight of Schneider Multi9 series C120? 1P:205 ...

Schneider inverter and PLC connection problems Schneider inverter and PLC connection problems

When the inverter is used to form an automatic control system for control, in many cases, PLC and inverter are used together, and how to correctly connect the PLC and inverter together has become the key to the success of the system. 1.PLC switch ...

Schneider inverter motor control mode Schneider inverter motor control mode

Fundamentals of magnetic flux vector manipulation The control of a three-phase asynchronous motor is much more complicated than that of a DC motor because the current, voltage, induced potential, magnetic flux, etc., of the stator and rotor are all alternating. However, the stator winding of the three-phase asynchronous motor is a symmetrical three-phase winding, which exerts a ...

Schneider inverter frequently asked questions Schneider inverter frequently asked questions

1. Schneider inverter uses analog output port to indicate the motor frequency, when the motor frequency is 50Hz, why is the output only 16mA? Answer: Because of the large output frequency parameter "TFR" of the inverter, the factory default value is 60Hz. So when the inverter output is 50Hz, the analog output is ...

Power wiring requirements for Schneider PLC Power wiring requirements for Schneider PLC

The power supply of the DPLC should be taken from the trunk line with a relatively stable voltage or the special line led by the bus of the substation to ensure the voltage quality of the PLC. If the voltage fluctuates too much, consider installing a voltage regulator or uninterruptible power supply (UPS). 2. The power cord is best to use twisted pair, and its cross-sectional area should not be less than 2 square millimeters.

The form of power input and output - Schneider The form of power input and output - Schneider

1. Single-phase input/single-phase output: If the capacity is relatively small, the single-entry UPS hanging on any phase of the mains will not be troublesome to the three-way distribution balance of the mains, the load capacity is small, and the output line diameter (current value) of the single-phase output is not ...

How Schneider UPS properly configures the backup battery How Schneider UPS properly configures the backup battery

In order to ensure that the APCUPS power supply can continue to supply high-quality power to the computer even in the event of a power outage, it is important to equip the battery backup battery. When the load is not allowed to be powered, the UPS battery backup time in the communication room should be greater than the time from the mains power interruption to the rehabilitation or to the generator set is positive.

Schneider Electric executive support merger software Saas company Schneider Electric executive support merger software Saas company

MergerWare has raised an undisclosed amount of money ahead of its Series A funding round, an executive told TechCircle. The Company provides software solutions to help integrate mergers and acquisitions-related businesses. The funding came from electrical equipment manufacturer Schneider Electric (Schneider ...

Knowledge of Schneider Lexium32 servo motors Knowledge of Schneider Lexium32 servo motors

Schneider Lexium32 servo motor new generation servo release enriches Schneider Electric's high-end product line, its outstanding product functions, sensitive openness and user-friendly planning will better meet the high functional and safety requirements of industrial customers. In China's industrial production is increasingly moving towards energy-saving ...

Precautions for external wiring of the inverter Precautions for external wiring of the inverter

In the process of connecting the line of the inverter, it is necessary to pay attention to the following aspects: 1. The power supply must be connected to the main circuit power terminal L1/R, L2/S, L3/T, if the power supply is connected to other terminals by mistake, the inverter will be damaged. 2. It is necessary for the grounding terminal to be well connected.

Whether an AC circuit breaker can be used in a DC circuit Whether an AC circuit breaker can be used in a DC circuit

Schneider circuit breakers are used to open and break communication loops. The arc extinguishing of the communication system is simple, but the arc extinguishing of the DC system is more difficult. Because the system is different and the arc extinguishing principle is different, there is a big difference in structure and performance between the communication circuit breaker and the DC circuit breaker. Compared with the communication circuit breaker, the DC circuit breaker ...

Schneider UPS power supply installation precautions Schneider UPS power supply installation precautions

The quality of UPS power supply devices directly affects the long-term operation of the UPS system in the future, especially the large and medium-sized UPS power supplies, so the large and medium-sized UPS power supplies should be standard in the process of planning to the device. Generally speaking, UPS power supply ...

Advantages of Schneider molded case circuit breaker Advantages of Schneider molded case circuit breaker

The contact orientation is 100% secure As for the circuit breaker, the indication of the handle can also be said to be the fault indicator of the circuit breaker, if it is "blurred" for a while, it may cause irreparable damage. Therefore, according to the requirements of the national standard, in any case, the hand of the circuit breaker ...

Schneider inverter ATV32 acceleration and deceleration operation method Schneider inverter ATV32 acceleration and deceleration operation method

1. Use the operation method of clicking the button: In addition to the direction of travel, 2 logic inputs are required to add a speed given, e.g. LI5 is assigned the acceleration function, and LI6 is assigned the deceleration function. Then pressing LI5 will make the speed given increase, and pressing LI6 will make the speed given speed decrease ...

Fault check steps for frequency converters - Schneider frequency converters Fault check steps for frequency converters - Schneider frequency converters

1. Check whether the appearance of the inverter is in good condition, including whether the indicator light is running normally, whether the task control function of the operation panel is complete, and carefully observe the appearance of the inverter in the operating state, and do the corresponding recording work; When repairing the inverter, check whether the voltage value and current value exceed the allowable ...

Schneider XPS safety control module selection method Schneider XPS safety control module selection method

(1) Evaluate the safety control level that the machinery and equipment need to reach (2) Confirm the type of input signal to be monitored and (3) the number of input signals that need to be monitored (4) The number and type of channels that the module needs to output (5) Whether it is necessary to control the output device (such as ...

Schneider appeared at the 5th China Power Distribution Technology Summit Forum Schneider appeared at the 5th China Power Distribution Technology Summit Forum

Beijing, China, September 14, 2020 – Today, the 5th China Power Distribution Technology Summit Forum 2021, held by China Electric Power Research Institute Co., Ltd. and the Science and Technology Development Service Center of China Electric Power Council, opened in Beijing. The theme of this forum is "Supporting the Strategic Policy of Carbon Peaking and Carbon Neutrality, Building a ...

Frequency converters and their control – Schneider Frequency converters and their control – Schneider

AC inverter is the result of the high development of microcomputer and modern power electronics technology. The microcomputer is the center of the inverter, and the power electronics form the main circuit of the inverter. As we all know, the frequency of communication electricity sent from power plants is stable and constant, in our country it is 50 weeks per second ...

Schneider miniature circuit breaker problem analysis and answer Schneider miniature circuit breaker problem analysis and answer

Fault 1: The shell of Schneider MCB product is yellowed or burned. Reason 1: It is very likely that the magnetic coil inside the circuit breaker is burned out because of harmonics or high-frequency signals. Method 1: * The good thing is that the filtering can be satisfied with the use of 50Hz/60Hz power frequency. ...

Schneider circuit breaker maintenance Schneider circuit breaker maintenance

1. Insist that the air is moist or unclean, and the pipes are not clean, which may have the following consequences: (1) The wet gas is decomposed into mixed gases such as hydrogen and oxygen under the action of the arc, and the insulation between the fractures after the main contact is broken is destroyed.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top