Inverter maintenance mantra method - Schneider

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

Don't worry about the damage of the frequency conversion, disassemble the machine after the discharge;

It is indispensable to ask for a diagnosis and clarify the problem at the beginning of the test;

Input and output PN junction, three-phase balance and then unshelling;

Look at the nameplate before powering on, the wrong voltage will blow up;

The bus is safe without electricity, and the rectifier filter is wrong for pressure sensitivity;

There is no electricity on the bus, and the switching power supply goes to make up for the lesson.

It appears that the motherboard is messy and dismantled, and eighty percent of the program has to be rewritten;

Showing normal error reporting, problem code check manual;

Undervoltage and overvoltage are the most common, and resistance sampling and op amp calculations;

The current transformer is prone to error;

The overheating error is unstable, and the fan does not turn thermal disconnecting;

The main control chip has many functions, and it is the expansion of detection;

Run without reporting an error when powering on, two methods to test the machine;

The panel controls the adjustment parameters, and the terminal controls the signal;

The overcurrent in operation is very simple, and the driving circuit should be looked at first.

Module damage is also common. If the motor is going to shake,

The three-phase voltage is unbalanced, and the optocoupler or capacitance should be checked.

Lack of phase is generally checked on the periphery, broken wire or bad touch;

Parameter reset must be cautious, on-site backup to two people,

There are many other problems, and you can't go wrong by looking at the map.

                         Inverter maintenance mantra method - Schneider

More on that
Precautions for the installation of low-voltage electrical appliances - Schneider Precautions for the installation of low-voltage electrical appliances - Schneider

1. Low-voltage electrical appliances should be equipped in a place without violent vibration, and should have an appropriate height from the ground. It is necessary to connect the power cord such as the knife switch and the load switch to the fixed contact, and it is forbidden to hang the power cord on the knife switch. 2. Low-voltage ...

Schneider inverter motor control mode Schneider inverter motor control mode

Fundamentals of magnetic flux vector manipulation The control of a three-phase asynchronous motor is much more complicated than that of a DC motor because the current, voltage, induced potential, magnetic flux, etc., of the stator and rotor are all alternating. However, the stator winding of the three-phase asynchronous motor is a symmetrical three-phase winding, which exerts a ...

Switching power supply circuit fault phenomenon - Schneider Switching power supply circuit fault phenomenon - Schneider

1. The power supply voltage of the secondary load is 0V. There is no response after the inverter is powered on, there is no indication on the operation display panel, and the 24V and 10V voltages of the measurement and control terminals are 0V. Check that the charging resistance or pre-charging circuit of the main circuit is correct, which can be identified as a switching power supply fault. The overhaul process is as follows: 1 ...

Schneider UPS Energy Saving Method Schneider UPS Energy Saving Method

1. Flexible planning for on-demand expansion Generally, the construction of data centers is not in one step, and the expansion of the next few years will be considered, and the UPS capacity is generally considered to be larger in the design.

Safety PLC is different from ordinary PLC Safety PLC is different from ordinary PLC

A safety PLC differs from conventional PLCs in that it needs to be certified for safety by a third-party professional organization and meet stringent international standards for safety and reliability. There is a need for a thorough systematic approach to the planning and testing of safety PLCs. TUV*** in Germany and FM*** in United States ...

Schneider PLC failure steps Schneider PLC failure steps

(1) If the signal is controlled on a counter, first look at the logic that controls the reset, then the counter signal. Follow steps 2 to 5 above. (2) If Schneider PLC aborts in some places where the output is encouraged, generally in the middle of the situation, then look for the next step ...

Schneider ATV32 inverter malfunction Schneider ATV32 inverter malfunction

1. The ATV32 inverter reports that the bLF is a brake control fault. Possible causes: 1. The brake release current is not reached. 2. When the braking logic control is assigned, only the closing frequency threshold [brake closure frequency] (bEn) is adjusted. Repair measures: 1. Check the inverter/electric ...

Schneider instrumentation maintenance precautions Schneider instrumentation maintenance precautions

1. Don't blindly knock and bump when overhauling to avoid expansion failures, and the more you repair, the worse it gets. 2. Do not plug and unplug various control boards and plugs with electricity. Due to the strong induced electromotive force generated by plugging and unplugging the control board under the power-on condition, the instantaneous ...

Automatic control instrument construction content and procedures - Schneider Automatic control instrument construction content and procedures - Schneider

1. Construction preparation. Including the preparation of operating conditions (construction skills documents and detailed planning documents), construction organization planning, equipment list, data budget, and list of machined parts; 2. Cooperate with civil engineering majors to do a good job of embedding, ...

Schneider AC contactor precautions Schneider AC contactor precautions

There are many series of contactors: LC1-SK series: below 6ALC1-K series: 6A-16ALC1-D series: 9A-150ALC1-F series: 115A-800ALC1-B series: 750A-1800A When installing, it should be in accordance with the regulations...

Schneider touch screen touch deviation causes Schneider touch screen touch deviation causes

(1) Problem 1: Contact deviation Phenomenon 1: The direction of the finger does not coincide with the mouse arrow. Reason 1: After installing the driver, there is no vertical contact with the bullseye when checking the alignment. Deal 1: Correct the position from the beginning. Phenomenon 2: ...

Suppression of higher harmonics of inverter - Schneider Suppression of higher harmonics of inverter - Schneider

1. About the management of higher harmonics on the output side of the inverter The magnetic noise skills brought about by the communication harmonic components contained in the output waveform controlled by PWM control have been increasingly used in various inverters, such as the selection of higher frequency switching components, the installation of filter devices at the output end of the inverter, etc.

Frequency converter and PLC connection problems - Schneider Frequency converter and PLC connection problems - Schneider

When the inverter is used to form an automatic control system for control, in many cases, the PLC and the inverter are used together, and how to correctly connect the PLC and the inverter together has become the key to the success of the system. 1.PLC switch ...

Functions of input/output pins P0, P1, P2, P3 – Schneider Functions of input/output pins P0, P1, P2, P3 – Schneider

P0.0——P0. 7 : Port P0 is an 8-bit open-drain bidirectional I/O port. When visiting off-chip memory, it is time-shared for a low-8-bit address and an 8-bit bidirectional data bus. When EPROM is programmed, the instruction byte is input by P0, and when the program is verified, it outputs ...

The difference between vector and general use of inverter - Schneider The difference between vector and general use of inverter - Schneider

1. The control accuracy of the vector type is higher than that of the general-purpose type. 2. The vector type has a large output torque at low speed, which can make the motor get a larger starting torque, which is suitable for application in the occasion of heavy load starting, such as: high-power long belt, hoist, etc. If used in some of the more common fields ...

Input/output pins P0, P1, P2, P3 functions Input/output pins P0, P1, P2, P3 functions

P0.0——P0. 7 : Port P0 is an 8-bit open-drain bidirectional I/O port. When visiting off-chip memory, it is time-shared for a low-8-bit address and an 8-bit bidirectional data bus. When EPROM is programmed, the instruction byte is input by P0, and when the program is verified, it outputs ...

Maintenance and overhaul of frequency converters and soft starters Maintenance and overhaul of frequency converters and soft starters

The protection and viewing of inverters and soft starters is a useful means to prevent occasional equipment problems. In order to be useful for protection and inspection, inspection orders should be created to record and save the inherent characteristics of the equipment and the stability of the constituent parts, so as to prevent problems and problems that occur.

The difference between Schneider UPS and EPS power supply The difference between Schneider UPS and EPS power supply

1. Different safety standards UPS is mainly used to protect users' equipment or business from economic loss, and its product technical certification mainly includes Thiel certification, CQC certification, etc. The development of EPS power supply stems from the sudden failure of the power grid, in order to ensure the power safety and fire linkage needs, it can be supplied immediately.

Schneider diode selection experience and substitution method Schneider diode selection experience and substitution method

1. Selection of detection diode Point-contact germanium diodes are generally used for detection diodes, such as 2AP series. When selecting, the detection diode with high operating frequency, small reverse current and large forward current should be selected according to the specific requirements of the circuit. Although the detection and rectification of ...

The difference between vector inverter and general-purpose inverter - Schneider The difference between vector inverter and general-purpose inverter - Schneider

There are two main differences between vector inverters and general-purpose inverters. One is high control accuracy, and the other is high output torque at low speed. Vector special inverter: The operating principle of the vector special inverter is to carry out inverter after rectification, ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top