Introduction to the transformer connection group - Schneider

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

In the transformer planning process, the choice of wiring method is often not paid attention to. The three-phase transformer has A/B/C three-phase winding on the 1/2 side. The connection between them has a great impact on the operation performance of transformers, especially distribution transformers, and directly affects the quality of power supply. Therefore, the choice of wiring method is also a very important task for transformer planning cameos.

A terminal transformer is a transformer primary and secondary winding in a combination of ways indicated in wiring; The in-phase high and low voltage windings of the transformer are all wound on the same core column and are wound by the same main magnetic chain. When the main magnetic flux changes, there is a certain polarity relationship between the induced potential in the high and low voltage windings.

                            Introduction to the transformer connection group - Schneider

At any given moment, the potential at one end of the high-voltage winding is positive, as is the potential at the other end of the low-voltage winding. The end of the same polarity between two windings is called the same end of the same title and is denoted as "·" and vice versa. Regarding the synonym ending, it is denoted as "-".

The transformer terminal group is a method of indicating the combination of the primary winding and the secondary system.

The common transformer winding has two connections, namely, "triangle connection" and "star connection"; The transformer coupling group "d indicates a triangular connection, "n" indicates a star connection with the neutral line, Y indicates a star, and n indicates a neutral band; '11' indicates the interline voltage on the primary side of the transformer and the secondary side of the transformer, with the line voltage UAB lagging UAB 330 degrees (30 degrees or higher).

The transformer wiring group is indicated by a capital letter of the primary side (or primary side) wiring mode, and by a lowercase letter of the secondary side (or secondary side) wiring mode.

y (or y) is a stellar connection, and d (or d) is a triangular connection. The digital is indicated by a clock, which is used to indicate the phase relationship between the first and second lateral voltages. The transverse voltage phasor is used as a minute hand and is fixed at the position of the clock point, and the secondary voltage phasor is used as an hour hand.

"YN, DL1", where 11 means that when the primary-side voltage phase is pointed to the 12:00 position of the clock as a thin needle, the line voltage phasor of the secondary side is located at the 11:00 position of the clock. That is, the line voltage UAB on the secondary side lags 330 degrees behind the primary voltage UAB (or 30 degrees ahead).

Two winding transformers formed by combining four end groups: "Y,Y,,d,Y,Y,d" and "d,d". Use only "Y,Y" and "Y,d". Since the band is also connected to the neutral line Y and both non-spaced, from the neutral there is no sign that is not added with the addition of the letter n after the neutral line Y. n indicates that the neutral score has a preemptive advantage there. YN0 wiring group, UAB and UAB together, refer to minute hand 12. The "12" terminal in the new group, in the table a "0" bit is simply said: the primary and three different sequences or their articulation ends in the secondary windings of the transformer to end on each side by induced alternating current corresponding to which the phase angle to the reference is different.

More on that
Features of Schneider explosion-proof inverter boxes Features of Schneider explosion-proof inverter boxes

1. Aluminum alloy shell or steel plate welding, plastic spraying on the surface; 2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies; ​ 3. It mainly regulates the general three-phase difference by changing its output frequency.

Schneider inverter external potentiometer connection Schneider inverter external potentiometer connection

The two wires are connected to the resistor, and the other wire is connected to the conditioning terminal. The red thread is attached to the blackhead and inserted in a small hole. Connect both ends of the IR potentiometer to +10V and ACM, and slide the termination to the voltage input terminal AVI. ...

Schneider ATV71 inverter installation and modulation setting steps Schneider ATV71 inverter installation and modulation setting steps

1. Schneider inverter menu: (1) Simple start: Self-tuning: If the manifestation is "unfinished", then select "supplication self-tuning" until the manifestation is "finished", i.e., the completion of self-tuning; Acceleration moment: a ...

Analysis of the reasons why the contact of Schneider contactor is not reliable Analysis of the reasons why the contact of Schneider contactor is not reliable

The unreliable contact touch will increase the touch resistance between the dynamic and static contacts, resulting in the high temperature of the touch surface, making the surface touch become a point touch, and even showing a non-conduction phenomenon. The reasons for this failure are: (1) There are ...

Schneider UPS power supply installation steps Schneider UPS power supply installation steps

UPS power supply is widely used in shopping malls, supermarkets, banks and other enterprises and institutions, the primary effect of the power supply is to provide continuous power supply for the unit in the state of power failure, so as to ensure the normal operation of the computer network system and other application systems, and effectively avoid data loss. In the power supply ...

Calculation method of inverter capacity - Schneider Calculation method of inverter capacity - Schneider

1. Accounting of inverter capacity when the load is continuously changed periodically In many cases, the load of the motor changes periodically. Obviously, in this case, picking the capacity of the inverter according to the minimum load will be overloaded, and it will be uneconomical to select according to the maximum load.

Heat dissipation strategy for frequency converters – Schneider Heat dissipation strategy for frequency converters – Schneider

Drives power and operate commercial and industrial motors, and thermal protection is necessary in accordance with their planning and operating environment. The main advantages of the frequency converters are flexible handling, smooth start-up and shutdown functions, and significant energy savings due to centrifugal fans and pumps operating under variable loads. ...

The 7 peripherals of the inverter governor - Schneider The 7 peripherals of the inverter governor - Schneider

1. Air circuit breaker is an active electrical appliance that can not only touch and disconnect the circuit normally, but also operate under abnormal conditions such as overcurrent, reverse current, short circuit and loss (under)voltage. Its primary role is to maintain the electrical equipment in the AC and DC circuits, and it can also operate the circuits infrequently. ...

Features of Schneider's different PLC series Features of Schneider's different PLC series

Schneider PLC series mainly includes: Schneider NEZA PLC (Schneider TSX08 series); Schneider Quantum PLC (Schneider 140 series); Schneider Micro PLC (Schneider TSX37 series); Schneider Premium PLC (Schneider TSX...

The difference between Schneider verification, calibration, and calibration The difference between Schneider verification, calibration, and calibration

What is the difference and contact between the instrument, external work verification, calibration, and calibration? Verification, calibration, and calibration are all static measurement processes that are carried out in cycles. The meanings are: The verification ---- shall be arranged by the legal metrology department or the statutory authorization in accordance with the verification procedures, after ...

The contents of the daily inspection of Schneider inverters The contents of the daily inspection of Schneider inverters

1) Whether the ambient temperature is normal or not, it is required to be in the range of -10-+40 °C, and it is better to be about 25 °C. whether the humidity meets the requirements, and whether the ventilation and heat dissipation of doors and windows are outstanding; Whether the lower air inlet and upper air outlet of the inverter are dusty or blocked due to excessive dust. ...

The difference between vector and general use of inverter - Schneider The difference between vector and general use of inverter - Schneider

1. The control accuracy of the vector type is higher than that of the general-purpose type. 2. The vector type has a large output torque at low speed, which can make the motor get a larger starting torque, which is suitable for application in the occasion of heavy load starting, such as: high-power long belt, hoist, etc. If used in some of the more common fields ...

Schneider inverter disturbance and treatment method Schneider inverter disturbance and treatment method

A. Methods of Communication: (1) Radiation disturbance (2) Conduction disturbance B. Immunity Methods With regard to nuisance signals transmitted by radiation methods, they are primarily weakened by wiring and shielding the radioactive source and the disturbed lines. About Tong ...

The reason for the frequent tripping of Schneider leakage switches The reason for the frequent tripping of Schneider leakage switches

1. Defective device The lead wire of each pile head is not firmly connected and loosened for a long time, which will cause the pile to heat and oxidize, burn out the outer insulation of the wire, and announce sparks and burnt smell, forming undervoltage of the line, and the air switch action. 2. The leakage switch does not match the load The actual electricity load of the home is large ...

Schneider inverter motor control mode Schneider inverter motor control mode

Fundamentals of magnetic flux vector manipulation The control of a three-phase asynchronous motor is much more messy than that of a DC motor because the current, voltage, induced potential, magnetic flux, etc., of the stator and rotor are all alternating. However, the stator winding of the three-phase asynchronous motor is a symmetrical three-phase winding, which exerts a ...

Schneider ATV630 VFD series advantages Schneider ATV630 VFD series advantages

Depending on the customer's requirements, wall-mounted drives, built-in cabinets and floor-mounted free-standing solutions in protection classes IP 21, IP 23, IP 54 and IP 55 are available. Thanks to the built-in pump monitoring function, the device reacts immediately when pump efficiency drops, resulting in ...

Schneider soft starter fault alarm maintenance method Schneider soft starter fault alarm maintenance method

1. Question-F 05 (frequency error): This problem is caused by a problem with the soft starter processing the internal power signal, which is causing errors in the power supply frequency. This situation needs to be handled by the company's product development software design engineer. Mainly start the power supply circuit design ...

Motor control mode of Schneider inverter Motor control mode of Schneider inverter

Fundamentals of magnetic flux vector manipulation The control of a three-phase asynchronous motor is much more complicated than that of a DC motor because the current, voltage, induced potential, magnetic flux, etc., of the stator and rotor are all alternating. However, the stator winding of the three-phase asynchronous motor is a symmetrical three-phase winding, which exerts a ...

Common maintenance problems for Schneider drives Common maintenance problems for Schneider drives

1. Why is the inverter used for fan and pump loads to save energy? According to the basic law of fluid mechanics, it can be seen that the fan pump load is a typical square rotation load, and its primary feature is that the speed n has the following relationship with the torque T and the load power P: T∝n2, P∝n3. ...

How Schneider contactors work How Schneider contactors work

1. Contactor refers to an electrical appliance that uses a coil to flow through an electric current to generate a magnetic field, so that the contact is closed, and then the load can be controlled. Because it can quickly block the main circuit and frequently connect the equipment with high-current control circuits, it has been widely used in electrical engineering.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top