Schneider Electric provides safe, reliable, end-to-end telemetry solutions to help you meet the challenges of long-distance operations. With an outstanding reputation in the fields of appearance, handling and data collection, wireless communications, IT, and other industries and common sense, Schneider Electric telemetry solutions can help you get the most out of your long-distance belongings.
Quickly lay out wireless appearances
Accutech sites that combine power, radio, and sensors are easy to set up. By eliminating wiring, trenches and pipes, the wireless system reduces the cost of layout by up to 75% compared with the traditional wired solution. All in all, high-performance, long-range, license-free radios and long-lasting batteries provide valuable data while significantly reducing support costs.
Sensitive and efficient controllers
The SCADAPack RTU manipulator offers a wide range of functions and options to provide sensitivity, and is easy to network, program and maintain. Running costs can be reduced by a dedicated development environment or our ClearSCADA host software that allows you to configure and edit logic online away from the site. The innovative circuit and firmware design can bring ultra-high efficiency mode and is suitable for solar-powered SCADA systems.
Efficient and intelligent SCADA host
ClearSCADA is a complete SCADA host platform with both innovation and agility. From built-in pre-history databases to alarm redirection, from target-based templates to multi-development loops, ClearSCADA effectively reduces operating costs by quickly deploying and reducing downtime in a secure, easy-to-use environment.
|
More on that
|
Precautions for the selection of Schneider molded case circuit breaker
1. Shell current and rated current
The size of the shell current is 100 (rated current 16 25 32 40 63 80 100) 250 (rated current 160 250 400 (rated current 250 400) 630 (rated current 630A.)
...
|
|
Schneider AC inverter usage category
Under the IEC60947-4 standard, the Schneider communication contactor TVR series must be able to turn on and break the current value, and these currents depend on the type of break that the load is turned on, including squirrel cage or slip ring motor, resistor, when the switch or break is generated in the motor abort, start or run...
|
|
Frequency characteristics of frequency converters – Schneider
a. Output frequency scale. The output frequency scale that can be controlled by the general inverter, the lowest starting frequency is generally 0.1Hz, and the highest frequency varies according to the functional indicators of the inverter, generally 400Hz, and some models are 650Hz. No matter how high the output frequency is, it depends on the scale of the high-frequency inverter.
...
|
|
Schneider Multi9 Series C120 FAQs
1. What are the characteristic curves of Schneider Multi9 series C120L?
A: C/D curve.
2. What is the rated current level of Schneider Multi9 series C120?
A: 63A, 80A, 100A, 125A.
3. Shi ...
|
|
Inverter terminal block classification - Schneider
Inverter terminal blocks belong to a kind of connector, the variety is divided into single hole, double hole, socket, hook, etc., from the data point, copper silver plating, copper galvanized, copper, aluminum, iron, etc. Their effect is mainly to transmit electrical signals or conductive use, in the project, it is the station front engineering for the station after the project reserved for the connection ...
|
|
Features of Schneider's different PLC series
Schneider PLC series mainly includes:
Schneider NEZA PLC (Schneider TSX08 series);
Schneider Quantum PLC (Schneider 140 series);
Schneider Micro PLC (Schneider TSX37 series);
Schneider Premium PLC (Schneider TSX...
|
|
Schneider instrumentation maintenance precautions
1. When installing and adjusting the appearance, the original status should be recorded for rehabilitation.
2. When repairing the appearance of fine instruments, if you accidentally bounce small parts away, you should first determine the direction where you can fly.
|
|
Anti-electromagnetic interference method - Schneider
There are three main sources of electromagnetic disturbance to the industrial system: first, space field disturbance, which enters the system through electromagnetic wave radiation; the second is power disturbance, which directly damages the system; The third is the signal disturbance channel, which enters the system through the front and rear channels connected to the host. In order to ensure that the instrumentation ...
|
|
How to choose the right inverter for the motor?
The inverter is an electric transmission element that is used in frequency conversion skills and microelectronics skills to control and communicate with the motor by changing the frequency and fluctuation of the power supply of the motor.
The birth of the inverter cabinet originated from the communication motor ...
|
|
Circuit breaker mechanical characteristics tester operation steps - Schneider circuit breaker
Circuit breaker action time test.
The closing and opening control lines of the circuit breaker mechanical characteristics tester are respectively connected to the secondary control line of the circuit breaker, and the lead wires of each break of the circuit breaker are connected to the mechanical characteristics of the circuit breaker with the test wiring.
|
|
Advantages and disadvantages of orifice flowmeters – Schneider
The orifice flowmeter is a high-range ratio differential pressure flow device composed of a standard orifice plate and a multi-parameter differential pressure transmitter (or differential pressure transmitter, temperature transmitter and pressure transmitter), which can measure the flow rate of gas, steam, liquid and natural gas. Widely used in petroleum, chemical, metallurgy, electric power ...
|
|
Schneider miniature circuit breaker C type D type difference
The difference between Schneider OSMC32N3D10 and OSMC32N3C10
After type comparison, one is Schneider D10A and the other is Schneider C10A.
Schneider circuit breaker type D, suitable for power equipment, such as motor load, air conditioner, etc.;
Schneider circuit breaker type C, suitable ...
|
|
Schneider molded case circuit breakers NSX, CVS, EZD differences
1. NSX series is Schneider's high-end molded case circuit breaker, with the best performance in all aspects, and of course, the price is also the most expensive.
2. CVS series, which is the main series of Schneider, has the second best performance compared with the NSX series, but can meet the vast majority of applications, and the price is more affordable.
3 ...
|
|
Commissioning steps for Schneider drives
1. Type recognition: Recognize whether the type of inverter is common with the type of inverter purchased.
2. Transportation acknowledgement: After opening the package, check whether the inverter is damaged during transportation.
3. Voltage recognition: the power supply voltage on the site should be borne by the inverter.
|
|
Pay attention to the problem when using UPS power supply - Schneider
1. The parameters set in the host cannot be changed at will during use. In particular, the parameters of the battery pack will directly affect the service life. With the change of ambient temperature, the float charge voltage should be adjusted accordingly. Generally, 25 °C is the standard, and when the ambient temperature rises or falls by 1 °C, the float charge ...
|
|
About the characteristics of Schneider explosion-proof inverter cabinet
1. Aluminum alloy shell or steel plate welding, surface spraying;
2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies;
3. It mainly regulates ordinary three-phase by changing its output frequency ...
|
|
How long does a UPS power supply last after a power outage – Schneider
The UPS power supply can supply power for a period of time after the power is cut off, but how long can the UPS power supply be powered after the power outage? UPS power supply manufacturers said that the power supply time of UPS power supply is inconsistent according to the load power, the number of batteries and other factors.
...
|
|
Schneider Vijeo-Designer compilation error factor
Q1833: Because you are using an older version of Runtime, the download does not last. Please use the Runtime Device program on the Vijeo Designer CD to upgrade the runtime.
When you download to an older runtime ...
|
|
The energy-saving effect of using frequency converter for fan and pump loads
Why is the use of inverter for fan and pump loads to save energy?
According to the basic laws of fluid mechanics, it can be seen that the fan pump load is a typical square rotation load, and its main characteristics are: speed n and torque T and load ...
|
|
Schneider inverter ATV61 OPF failure analysis
Q: 250KW ATV61 with 250KW fan, when decelerating to low speed, OPF (motor missing three-phase) problem will be reported occasionally. There are no contactors or switches between the inverter and the motor.
Answer: This situation seems to be a problem with the inverter, which is a false alarm. Not really! The fan is decelerating ...
|
|