Schneider inverter disturbance and treatment method

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

A. Methods of Communication:

(1) Radiation disturbance

(2) Conduction disturbance

B. Immunity Methods

With regard to nuisance signals transmitted by radiation methods, they are primarily weakened by wiring and shielding the radioactive source and the disturbed lines.

As for the nuisance signal transmitted through the line, it is mainly handled by installing filters, reactors or magnetic rings on the input and output sides of the inverter.

                               Schneider inverter disturbance and treatment method

The specific methods and precautions are as follows:

(1) The signal line and the power line should be vertically crossed or slotted and routed.

(2) Do not choose wires of different metals to connect with each other.

(3) The shielding pipe (layer) should be reliably grounded, and ensure continuous and reliable grounding on all lengths.

(4) Twisted pair shielded cables should be used in signal circuits.

(5) The shield connection address should be as far away from the inverter as possible and separated from the inverter connection address.

(6) The magnetic ring can be used on the input power line and output line of the inverter, and the specific method is: the input line is wound 4 times in the same direction, and the output line is wound 3 times in the same direction. When winding, it is necessary to pay attention to the magnetic ring as close to the inverter as possible.

(7) Generally, shielding and other anti-annoying methods can be adopted for the disturbed equipment and instruments.

More on that
Precautions for external wiring of the inverter Precautions for external wiring of the inverter

In the process of connecting the line of the inverter, it is necessary to pay attention to the following aspects: 1. The power supply must be connected to the main circuit power terminal L1/R, L2/S, L3/T, if the power supply is connected to other terminals by mistake, the inverter will be damaged. 2. It is necessary for the grounding terminal to be well connected.

Circuit breaker breaking capacity selection - Schneider Circuit breaker breaking capacity selection - Schneider

How to choose the circuit breaker break? Rated voltage and current are the key For professional electrical operators, the question of how to choose the circuit breaker can be said to be easy and effortless, but it is a bit difficult for novices. Circuit breaker breaking can ...

Schneider diode selection experience and substitution method Schneider diode selection experience and substitution method

1. Selection of detection diode Point-contact germanium diodes are generally used for detection diodes, such as 2AP series. When selecting, the detection diode with high operating frequency, small reverse current and large forward current should be selected according to the specific requirements of the circuit. Although the detection and rectification of ...

Schneider inverter frequently asked questions Schneider inverter frequently asked questions

1. Schneider inverter uses analog output port to indicate the motor frequency, when the motor frequency is 50Hz, why is the output only 16mA? Answer: Because of the large output frequency parameter "TFR" of the inverter, the factory default value is 60Hz. So when the inverter output is 50Hz, the analog output is ...

Frequency converters and their control – Schneider Frequency converters and their control – Schneider

AC inverter is the result of the high development of microcomputer and modern power electronics technology. The microcomputer is the center of the inverter, and the power electronics form the main circuit of the inverter. As we all know, the frequency of communication electricity sent from power plants is stable and constant, in our country it is 50 weeks per second ...

The reason for the inverter trip - Schneider The reason for the inverter trip - Schneider

Whenever the inverter is down due to a problem, a problem code will appear. The most common causes are overcurrent, overvoltage, inverter temperature, etc. It's a good idea to find an explanatory book with specific questions to be asked about. 1. Overload jump ...

Schneider drives copy replication parameters Schneider drives copy replication parameters

1. Copy and copy through the Chinese panel. Older inverters, if they support Chinese panels, such as ATV71, ATV61, etc., support VW3A1101 panels, they can use the proprietary 'open/save as' parameter on the panel to copy and copy, and the newer ATV610, ATV630, ATV930, ...

The difference between Schneider verification and calibration The difference between Schneider verification and calibration

(1) The intent is different The intent of the verification is to carry out a mandatory comprehensive appraisal of the measuring equipment. This comprehensive identification of areas attributed to the value of the same value is a top-down process of value transfer. The verification shall identify whether the measuring equipment meets the specified requirements. This kind of regulation requires ...

The reason for the frequent tripping of Schneider leakage switches The reason for the frequent tripping of Schneider leakage switches

1. Defective device The lead wire of each pile head is not firmly connected and loosened for a long time, which will cause the pile to heat and oxidize, burn out the outer insulation of the wire, and announce sparks and burnt smell, forming undervoltage of the line, and the air switch action. 2. The leakage switch does not match the load The actual electricity load of the home is large ...

Schneider instrumentation maintenance precautions Schneider instrumentation maintenance precautions

1. Don't blindly knock and bump when overhauling to avoid expansion failures, and the more you repair, the worse it gets. 2. Do not plug and unplug various control boards and plugs with electricity. Due to the strong induced electromotive force generated by plugging and unplugging the control board under the power-on condition, the instantaneous ...

Schneider instrumentation winter insulation measures Schneider instrumentation winter insulation measures

The methods adopted usually are: selection, thermal insulation and heat tracing, protection (point inspection, sewage discharge) and so on. Selection method Choose the appearance of the type with insulation equipment. According to the category and use of the appearance and the geographical location of the proposed equipment, the insulation and antifreeze requirements of the appearance are proposed, and then submitted to the manufacturer for processing. ...

How to identify the quality of an inverter – Schneider How to identify the quality of an inverter – Schneider

Nowadays, the function of domestic inverters is becoming more and more mature, with a wide variety and dazzling. Many brands have been tested by the market, but there are also some brands that have been imitated and counterfeited to disrupt the market. One of the major characteristics of domestic brands is that they are both like domestic brands and imported brands. The brand's ...

Schneider inverter ATV32 acceleration and deceleration operation method Schneider inverter ATV32 acceleration and deceleration operation method

1. Use the operation method of clicking the button: In addition to the direction of travel, 2 logic inputs are required to add a speed given, e.g. LI5 is assigned the acceleration function, and LI6 is assigned the deceleration function. Then pressing LI5 will make the speed given increase, and pressing LI6 will make the speed given speed decrease ...

Advantages of Schneider molded case circuit breaker Advantages of Schneider molded case circuit breaker

The contact orientation is 100% secure As for the circuit breaker, the indication of the handle can also be said to be the fault indicator of the circuit breaker, if it is "blurred" for a while, it may cause irreparable damage. Therefore, according to the requirements of the national standard, in any case, the hand of the circuit breaker ...

Schneider circuit board maintenance work commonly used instrumentation Schneider circuit board maintenance work commonly used instrumentation

Before preparing to do circuit board repair work, you should prepare some things and appearances to help repairers better carry out circuit board repair operations, according to our circuit board repair training center for many years of experience has shown that prepare some necessary circuit board repair things and appearance, to be able to reach ...

The way the frequency of the inverter is given – Schneider The way the frequency of the inverter is given – Schneider

The given frequency refers to the frequency at which the inverter is set to operate, and the given frequency can be given by the operation panel or by the external method, during which the external method is divided into voltage and current. First, the operation panel is given a frequency ...

Inverter fault repair - Schneider Inverter fault repair - Schneider

To repair the output board driven by the inverter, we must first investigate whether the components on the PCB board are burned out, replace them first, and then analyze what causes the burned out and deal with this problem. And then...

Schneider ATV71 inverter installation and modulation setting steps Schneider ATV71 inverter installation and modulation setting steps

1. Schneider inverter menu: (1) Simple start: Self-tuning: If the manifestation is "unfinished", then select "supplication self-tuning" until the manifestation is "finished", i.e., the completion of self-tuning; Acceleration moment: a ...

Features of Schneider elliptical gear flowmeter Features of Schneider elliptical gear flowmeter

Elliptical gear flowmeter (also known as displacement flowmeter, gear flowmeter), classified as a positive displacement flowmeter, is a class with high accuracy in the flow surface. It uses a mechanical measuring element to continuously cut the fluid into a single known volume part, and according to the measuring chamber, it is repeated and repeated.

Precautions for Schneider to use USP power supplies Precautions for Schneider to use USP power supplies

(1) When using Schneider UPS power supply, the relevant provisions of the manufacturer's product manual should be strictly adhered to ensure that the front and zero line sequences of the mains connected by Schneider UPS meet the requirements. (2) The main intention of equipping Schneider UPS is to prevent the computer from losing information due to a sudden power failure...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top