Before preparing to do circuit board repair operations, you should prepare some things and appearances to help repairers better carry out circuit board repair operations, according to our circuit board repair training center for many years of experience, prepare some necessary circuit board repair things and appearance, can achieve twice the result with half the effort, sharpen the knife without mistake the role of woodcutters. The things and appearance that you should have when performing a circuit board repair are summarized below.
(1) circuit board online repair tester: circuit board repair tester can detect the function and quality of each digital series integrated circuit and imitation integrated circuit online, it is a relatively easy to use high-end repair instrument, but the price is expensive, the price ranges from tens of thousands of yuan to hundreds of thousands of yuan, the cheap can not detect the quality of the imitation integrated circuit, and the expensive one has the function of imitating the quality of the integrated circuit. It is recognized as the most professional repair instrument in the circuit board repair industry in all countries around the world. It brings great convenience to repair. In China, there are many applications of Huineng electronic circuit fault online repair tester produced by Beijing Tianhui Weice Electronics Co., Ltd., the quality is also good, and the function is also more.
(2) Oscilloscope: It can detect the input and output waveforms of the critical points in the circuit board, and accurately identify the parts that cause problems according to the detected waveforms.
(3) Various programmers: the programmer can read out the data in the memory chip when repairing the circuit board, which is convenient for the repair personnel to backup, and can burn the read data into the blank memory chip for backup when the memory chip is faulty.
(4) (digital/pointer) multimeter: multimeter is the most cheap and practical repair appearance, the price is between tens of yuan and thousands of yuan, can detect the quality of each component in the circuit board, but also can detect the voltage and current data of the critical points in the circuit board.
(5) Circuit short circuit tracker: When carrying out circuit board repair operations, it is often encountered that the power supply or other circuits are short-circuited, and if there is a circuit short-circuit tracking, it is very convenient to find out the cause of the short circuit.
(6) EPROM eraser: used to erase the data in the memory chip to facilitate reuse and save repair costs.
(7) signal generator: circuit board repair work is generally not in the equipment site, how to add a signal to the input circuit of the circuit board, the signal generator is very important, the signal generator can be used to imitate the signal in the equipment to add to the circuit board during repair, and then use the oscilloscope to determine the waveform of the output circuit, which can quickly identify the part of the fault.
(8) Logic analyzer: used to detect the logic level of the logic equipment in the circuit board to identify the part of the problem.
(9) Constant temperature blowing and soldering station, hot air gun: used to solder the components on the circuit, especially the integrated circuit equipment, which is very easy to use.
(10) Constant temperature electric soldering iron, rosin, solder wire: used to solder electronic components in the circuit board.
(11) Anti-static gloves: when repairing the circuit board, sometimes the collar will produce static electricity, damage the integrated circuit in the circuit board, in order to prevent the components in the circuit board from being damaged by human static electricity, you can wear anti-static gloves during the repair operation, you can deal with the situation of accidental damage to the components due to static electricity.
(12) IC puller: used to pick up the IC plugged into the IC socket in the circuit board.
(13) Bridge tester, capacitance meter, inductance meter, etc
(14) Small things such as needle-nose pliers, diagonal pliers, tweezers, wall clock batches, etc.
After all, when engaged in circuit board repair operations, it is necessary to prepare a relatively easy to use instrument appearance and common things to achieve the purpose of quickly repairing the circuit board.
|
More on that
|
Schneider miniature circuit breaker C type D type difference
The difference between Schneider OSMC32N3D10 and OSMC32N3C10
After type comparison, one is Schneider D10A and the other is Schneider C10A.
Schneider circuit breaker type D, suitable for power equipment, such as motor load, air conditioner, etc.;
Schneider circuit breaker type C, suitable ...
|
|
Inverter maintenance mantra method - Schneider
Don't worry about the damage of the frequency conversion, disassemble the machine after the discharge;
It is indispensable to ask for a diagnosis and clarify the problem at the beginning of the test;
Input and output PN junction, three-phase balance and then unshelling;
Look at the nameplate before powering on, the wrong voltage will blow up;
The bus has no electricity to see that it is safe, and the rectifier filter is wrong ...
|
|
Knowledge of Schneider Lexium32 servo motors
Schneider Lexium32 servo motor new generation servo release enriches Schneider Electric's high-end product line, its outstanding product functions, sensitive openness and user-friendly planning will better meet the high functional and safety requirements of industrial customers. In China's industrial production is increasingly moving towards energy-saving ...
|
|
Schneider molded case and miniature circuit breaker recommended models
Molded case circuit breaker recommendation
Schneider EZD series
Create a high-quality circuit breaker for secondary power distribution
EZD molded case circuit breaker is a product series of molded case circuit breakers specially designed for secondary power distribution by Schneider Electric, which is especially suitable for ...
|
|
Inverter trip protection circuit – Schneider
After the maintenance function of the inverter is caused by the operation of the problem, it will trip immediately, and the fault code will be displayed together, and the tripping alarm indication circuit of the peripheral inverter will send out an audible and visual alarm to remind the operator to clean up the problem in time.
Inverter hopping ...
|
|
Schneider Instrumentation Classification Standard
The classification specifications for the appearance of the instrument are as follows:
The appearance of the instrument is a comprehensive product of a variety of science and technology, with a wide variety of varieties, wide application, and constantly updated, and a variety of classification methods. According to the purpose and use of the use of the main measuring instrument, car appearance, tractor appearance, marine ...
|
|
Circuit breaker failure protection - Schneider
Circuit breaker failure maintenance refers to the relay maintenance action of faulty electrical equipment when the trip command is announced and the circuit breaker refuses, the maintenance action information of the faulty equipment and the current information of the rejected circuit breaker constitute the judgment of circuit breaker failure, and other related problems in the same plant and station are cut off in a shorter time limit.
|
|
The ultimate short-circuit breaking capacity of Schneider circuit breakers
The limit short-circuit breaking ability (ICU) refers to the short-circuit current that can be turned on and broken under certain experimental parameters (voltage, short-circuit current, power factor) and through a certain experimental procedure, and after this on-off, it will no longer continue to carry its rated current. It's experiments ...
|
|
Analysis of the reasons why the contact of Schneider contactor is not reliable
The unreliable contact touch will increase the touch resistance between the dynamic and static contacts, resulting in the high temperature of the touch surface, making the surface touch become a point touch, and even showing a non-conduction phenomenon. The reasons for this failure are:
(1) There are ...
|
|
Switching power supply circuit fault phenomenon - Schneider
1. The power supply voltage of the secondary load is 0V. There is no response after the inverter is powered on, there is no indication on the operation display panel, and the 24V and 10V voltages of the measurement and control terminals are 0V. Check that the charging resistance or pre-charging circuit of the main circuit is correct, which can be identified as a switching power supply fault. The overhaul process is as follows:
1 ...
|
|
Diode selection and substitution method - Schneider
1. Selection of detection diode
Point-contact germanium diodes are generally used for detection diodes, such as 2AP series. When selecting, the detection diode with high operating frequency, small reverse current and large forward current should be selected according to the specific requirements of the circuit. Despite the ...
|
|
Suppression of higher harmonics of inverter - Schneider
1. About the management of higher harmonics on the output side of the inverter
The magnetic noise skills brought about by the communication harmonic components contained in the output waveform controlled by PWM control have been increasingly used in various inverters, such as the selection of higher frequency switching components, the installation of filter devices at the output end of the inverter, etc.
|
|
Deterioration site and the principle of higher harmonic generation - Schneider
1. Electrical equipment will produce higher harmonics when it produces abnormality and deterioration, and the abnormality and deterioration of motors, loads, and inverters are used to distinguish the higher harmonics from 2 to 40 times, and the data is changed by FFT, and the analysis is made on the basis of the analysis data of long-term savings.
|
|
Introduction to Schneider inverter fault code and maintenance method
1. If the fault code presented on the Schneider inverter is AnF, it means that the load of the inverter has slipped, that is, the speed of the encoder does not match the initial value. First of all, we need to check whether the parameters of the motor are stable and the size of the load, ...
|
|
Introduction to the core knowledge and application of instrumentation - Schneider
Although the "measurement and control skills and instruments" category of majors touch the fields of national defense, aerospace, aviation, sailing, railway, machinery, light industry, chemical industry, electronics, electric power, telecommunications, metallurgy, petroleum, mining, geology, surveying and other industrial, agricultural and scientific research categories, the Ministry of Education has a special understanding of "measurement and control skills and instruments".
|
|
The energy-saving effect of using frequency converter for fan and pump loads
Why is the use of inverter for fan and pump loads to save energy?
According to the basic laws of fluid mechanics, it can be seen that the fan pump load is a typical square rotation load, and its main characteristics are: speed n and torque T and load ...
|
|
Schneider PLC intelligent parameter features
Characteristic:
1. NEZA PLC (TSX08 series)
EZA series is a small PLC with rich functions, high performance-to-price ratio, small size and strong versatility.
A new generation of handheld programmer - Chinese PDA PL707WinCE, supports Chinese interface, whether it is programming, ...
|
|
The difference between an inverter and a servo drive – Schneider
In terms of frequency converters:
The abbreviated inverter can only regulate the speed of the communication motor, and the open-loop or closed-loop can be determined depending on the control method and the inverter, which is the traditional V/F control method. Now many of the frequency conversion has been set up by mathematical models, which will communicate electricity ...
|
|
The UPS boot panel does not show that the UPS is not working - Schneider
Problem: After the UPS is turned on, there is no display on the panel, and the UPS does not work
Problem analysis: Judging from the problem phenomenon, the problem lies in the mains input, the battery and the mains detection part and the battery voltage detection loop:
1. Check ...
|
|
Schneider instrumentation accuracy
It refers to the degree to which the average value measured repeatedly under certain test conditions is consistent with the true value, which is indicated by error. It is used to indicate the magnitude of the error in the system. In practice, control tests are generally carried out with standardized substances or normative methods, and when there are no standardized substances or normative methods, it is often used to add ...
|
|