Turbine flowmeter selection factor - Schneider

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

Turbine flowmeter is a kind of speed appearance, it has high precision, good repeatability, no zero drift, high range ratio, simple structure, few moving parts, high pressure resistance, wide measurement scale, small size, light weight, small pressure loss, convenient repair and other advantages, turbine flowmeter has high-quality bearings, specially planned deflectors, so it greatly reduces wear, is not sensitive to peak values, and can give reliable measurement variables even under harsh conditions. It has a wide range of application value in petroleum, chemical industry, metallurgy, food, biochemistry, city gas pipeline network and other industries.

                            Turbine flowmeter selection factor - Schneider

How to choose a turbine flowmeter consider the following aspects;

1. According to the requirements of measurement intention:

It is required to select the instantaneous flow rate is still the cumulative flow rate (cumulative flow), the unit of flow display, measurement accuracy, repeatability, linearity, flow scale and scale, measurement temperature, pressure loss, temperature and pressure compensation, output signal characteristics and response time, etc. Different measurement targets have their own measurement intentions, and have different emphases in the performance of turbine flowmeters.

2. Requirements for measuring the properties of the medium:

Chemical corrosion and fouling, the chemistry of the fluid can sometimes be the determining factor in the selection of measurement methods and appearances. Some fluids can cause corrosion of the surface contact parts, scaling on the surface or electrolytic chemical reaction on the surface of the metal surface of the crystalline body.

3. Requirements for measuring the phase of the medium:

Depending on whether the measurement medium is a single phase change medium or a multiphase and multi-component flow, caution should be exercised. The turbine flowmeter can measure a single clean medium, and the electromagnetic flowmeter can measure the solid-liquid two-phase mixed medium.

4. Turbine flowmeter is a common type of flow, which can measure various gases and liquids. It uses a new intelligent planning to maintain high-precision measurement when it is used. The performance of the turbine flowmeter in use is superior, the service life is very long, and it has a strong anti-disturbance ability, in the time of use, the turbine flowmeter may encounter various electromagnetic disturbances, if the anti-disturbance ability of the flowmeter is not good enough, the measurement accuracy of the flowmeter may be affected when it is used.

When the turbine flowmeter is in use, the power consumption is small, and the stainless steel structure is selected, which can ensure that it has strong anti-corrosion performance during the application, and it is not simply corroded, and for some corrosive media, the turbine flowmeter can also be measured well and will not be limited. This turbine flowmeter is very small, if there is a failure during use, it is very simple to disassemble the flowmeter, which is convenient for the user to repair in time, and after daily use, when the flowmeter needs to be cleaned, the simple disassembly and assembly also makes the user more convenient to clean

5. Measurement accuracy requirements:

The requirements for the overall measurement accuracy requirements and the use of a specific flow rate are still significant changes due to temperature and pressure changes in a certain scale of measurement, and its values are generally low, and the differences between various gases are small. The commonly used accuracy grades of intelligent liquid turbine flowmeters are 1.0 and 0.5, which are higher than general rotor flowmeters, and it is a good choice for customers with high accuracy requirements.

More on that
Schneider inverter control circuit Schneider inverter control circuit

1. What is a control loop? The network that supplies the control signal to the main circuit that supplies power to the asynchronous motor (voltage and frequency can be adjusted) is called the control loop. Second, the composition of the control loop The control circuit is controlled by the frequency ...

Schneider inverter ATV310 instruction with given Schneider inverter ATV310 instruction with given

The instructions of the inverter are given with the given conf→400- → 401 (given channel), → 01 (given analog terminal), 163 (given by remote display terminal), 164 (given by mudobus communication), 183 (navigation knob ...

Inverter selection principle - Schneider Inverter selection principle - Schneider

1. Select the inverter according to the load characteristics. 2. When selecting the inverter, the actual motor current value should be used as the basis for the selection of the inverter, and the additional power of the motor can only be used as a reference. Secondly, the output content of the inverter should be fully considered.

The difference between Schneider UPS and EPS power supply The difference between Schneider UPS and EPS power supply

1. Different safety standards UPS is mainly used to protect users' equipment or business from economic loss, and its product technical certification mainly includes Thiel certification, CQC certification, etc. The development of EPS power supply stems from the sudden failure of the power grid, in order to ensure the power safety and fire linkage needs, it can be supplied immediately.

Inverter power-saving method - Schneider Inverter power-saving method - Schneider

First, it is a fan/pump load Second, the device itself has a power-saving function (software support) Third, we need to work for a long time The above are the three conditions that reflect the results of power saving. If it is said that the power frequency of the inverter is energy-saving without conditions, it is ...

Schneider inverter ATV32 book type performance and advantages Schneider inverter ATV32 book type performance and advantages

Schneider ATV32 book inverter has built-in programmable controller function, flexible and intelligent; Integrated safety functions, 30% cost savings compared with external security modules; First-class Schneider patented synchronous motor open-loop control technology; Book-type design, support side-by-side installation, space-saving; Many...

The difference between Schneider and Siemens PLC The difference between Schneider and Siemens PLC

There are three main differences, namely: different uses, different products, and different characteristics. 1. Different use cases: The programmable manipulator produced by Siemens in Germany is also widely used in China, and has been used in metallurgy, chemical industry, printing production lines and other fields.

Schneider inverter maintenance precautions Schneider inverter maintenance precautions

Schneider Electric intelligent special effect inverter maintenance, the daily maintenance of the inverter mainly depends on your use environment, such as moisture-proof, dust-proof, anti-foreign body ingress, pay attention to whether there is any abnormal sound when usually protecting. Attention to the needs of inverter protection ...

Schneider Electric has announced the launch of its Pacific Foundation Schneider Electric has announced the launch of its Pacific Foundation

Schneider Electric has announced the launch of its Pacific Foundation, which will provide financial and advisory support to charitable foundations in the Pacific region to address fundamental human rights issues of access to energy. Four foundations were selected as the Foundation's initial recipients.

Schneider drives copy replication parameters Schneider drives copy replication parameters

1. Copy and copy through the Chinese panel. Older inverters, if they support Chinese panels, such as ATV71, ATV61, etc., support VW3A1101 panels, they can use the proprietary 'open/save as' parameter on the panel to copy and copy, and the newer ATV610, ATV630, ATV930, ...

How to choose Schneider circuit breaker How to choose Schneider circuit breaker

The origin orientation is incorrect, and the encoder debugs/zeros the bit First, the value of the current at each branch is calculated (1) Purely resistive loads, such as bulbs, electric heaters, etc., are directly divided by the indicated power by the voltage. Formula I = power/220v; ...

Schneider inverter ATV61 OPF failure analysis Schneider inverter ATV61 OPF failure analysis

Q: 250KW ATV61 with 250KW fan, when decelerating to low speed, OPF (motor missing three-phase) problem will be reported occasionally. There are no contactors or switches between the inverter and the motor. Answer: This situation seems to be a problem with the inverter, which is a false alarm. Not really! The fan is decelerating ...

The difference between the highest frequency and the basic frequency of the inverter - Schneider The difference between the highest frequency and the basic frequency of the inverter - Schneider

1. There are two ways to say the fundamental frequency: (1) The frequency corresponding to the maximum output voltage of the inverter is called the fundamental frequency; (2) When the output voltage of the inverter is equal to the additional voltage, the minimum output frequency is called the fundamental frequency. The fundamental frequency is expressed in fBA. ...

Schneider instrumentation winter insulation measures Schneider instrumentation winter insulation measures

The methods adopted usually are: selection, thermal insulation and heat tracing, protection (point inspection, sewage discharge) and so on. Selection method Choose the appearance of the type with insulation equipment. According to the category and use of the appearance and the geographical location of the proposed equipment, the insulation and antifreeze requirements of the appearance are proposed, and then submitted to the manufacturer for processing. ...

Schneider Vijeo-Designer compilation error factor Schneider Vijeo-Designer compilation error factor

Q1833: Because you are using an older version of Runtime, the download does not last. Please use the Runtime Device program on the Vijeo Designer CD to upgrade the runtime. When you download to an older runtime ...

For the first time, Schneider presents a new lightweight MES in packaging For the first time, Schneider presents a new lightweight MES in packaging

Packaging Lightweight MES is a production line and workshop-level digital management and processing solution created by Schneider Electric based on more than 20 years of experience in packaging machine automation, combined with the digital transformation needs of the FMCG (Consumer Packaged Goods) profession, which can be widely used in food and beverage, life ...

The UPS boot panel does not show that the UPS is not working - Schneider The UPS boot panel does not show that the UPS is not working - Schneider

Problem: After the UPS is turned on, there is no display on the panel, and the UPS does not work Problem analysis: Judging from the problem phenomenon, the problem lies in the mains input, the battery and the mains detection part and the battery voltage detection loop: 1. Check ...

Circuit breaker breaking capacity selection - Schneider Circuit breaker breaking capacity selection - Schneider

How to choose the circuit breaker break? Rated voltage and current are the key For professional electrical operators, the question of how to choose the circuit breaker can be said to be easy and effortless, but it is a bit difficult for novices. Circuit breaker breaking can ...

Two of Schneider's low-voltage power distribution products won the Germany Red Dot Award Two of Schneider's low-voltage power distribution products won the Germany Red Dot Award

Beijing, China, April 6, 2022 – Recently, the list of "Red Dot Planning Awards", known as one of the world's three cutting-edge industrial planning awards, was grandly announced in Germany.

Common maintenance problems for Schneider drives Common maintenance problems for Schneider drives

1. Why is the inverter used for fan and pump loads to save energy? According to the basic law of fluid mechanics, it can be seen that the fan pump load is a typical square rotation load, and its primary feature is that the speed n has the following relationship with the torque T and the load power P: T∝n2, P∝n3. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top