Key points of operation of Schneider disconnectors

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

Features of Schneider Barrier Switch: First of all, Schneider Barrier Switch can be used to block the power supply, it can disconnect the live equipment from the high-voltage maintenance equipment, and can also see the obvious disconnection point on it. Secondly, the Schneider barrier switch can cooperate with the circuit breaker to achieve the purpose of changing the wiring method of system operation. Schneider block switches turn small current circuits on or off. In the high-voltage power distribution equipment, the barrier switch is more used, which can well ensure the safety of maintenance work.

                                 Key points of operation of Schneider disconnectors

Regarding the operation essentials of Schneider barrier switches, here Kexu Xiaobian will answer for you. It is divided into 3 parts. It contains the operation essentials when the barrier switch is closed, the barrier switch is opened, and the barrier switch is equipped with electromagnetic locking when the lock fails.

When performing the reverse operation, the operator must carefully check the true disconnection position of the circuit breaker. For the three-phase linkage barrier switch, the three-phase rise and fall should be at the same time, and the difference should not be greater than 3mm, so that the opening and closing operation of the barrier switch is allowed.

1. Essentials of barrier switch closing

If it is a manual operation, the operator should first dial out the interlocking pin and then close, the beginning should be slow, and when the moving contact is close to the static contact, it should be closed quickly to prevent arc light. If an arc occurs at the beginning of closing, the barrier switch should be closed immediately, and the operator is prohibited from pulling the barrier switch back, because the pullback will expand the arc light and cause further damage to the equipment. At the end of closing, the force should not be too strong to prevent the closing from being too deep and causing damage to the supporting porcelain bottle. After the barrier switch is closed, the operator should carefully check whether the closing is outstanding and whether the moving contact has completely entered the static contact, so as to prevent the dynamic and static contact from heating due to poor touch. For the reversing barrier switch on the rotating shaft, the blade should be on the plane of the straight fixed contact after closing, so as to ensure the pressure at the contact and the necessary touch resistance; For casement barrier switches, the blade should be turned to a horizontal position after closing, and its arm should be straightened. If the movable cap of the static contact is to the right, it means that the hammer rod of the moving contact arm is too closed.

When operating the outdoor barrier switch in winter, the freezing ice and frost and snow on the contact can be rubbed off by several times of connection and disconnection, so that the barrier switch can ensure that the dynamic and static contacts are excellent after closing. The condition for the reliable operation of the barrier switch is that when the barrier switch has transmission equipment, it should be ensured by its correct adjustment; If there is no transmission equipment, the correct operation of the insulating rod should be ensured. Barrier switches of various specifications are not allowed to fall off actively in the event of a short circuit, so the barrier switch should be locked with five anti-locking equipment when closing the direction. The personnel on duty need to carefully check these equipment, buckle the barrier switch with a pin after each barrier switch is closed, and lock the five-proof locking equipment to prevent the barrier switch from actively disconnecting and forming an accident.

2. The essentials of barrier switch opening operation

When the moving contact leaves the static contact, if an arc occurs, the operator should immediately close the barrier switch and stop the operation. However, when the small load current and charging current are blocked, the arc will occur when the barrier switch is opened, and the barrier switch should be disconnected quickly in order to eliminate the arc smoothly. At the end of the brake, it should be slow, this is to prevent the impact force on the damage to the supporting porcelain bottle and the operating mechanism, * after the operation personnel should check whether the interlocking pin is pin well. After the barrier switch is opened, the operator should carefully check the true disconnection direction of the barrier switch, the air insulation distance of the disconnection should be qualified, and check that the moving contact has indeed been pulled to the end, and the point of view of the swing should comply with the rules of the manufacturer. For indoor barrier switches, if the disconnected insulation distance is not enough, the insulating partition should be pierced, otherwise a discharge short circuit accident will occur on the live side and the side of the ground wire in case of power failure.

More on that
The difference between an inverter and a servo drive – Schneider The difference between an inverter and a servo drive – Schneider

In terms of frequency converters: The abbreviated inverter can only regulate the speed of the communication motor, and the open-loop or closed-loop can be determined depending on the control method and the inverter, which is the traditional V/F control method. Now many of the frequency conversion has been set up by mathematical models, which will communicate electricity ...

Schneider low-voltage circuit breaker selection Schneider low-voltage circuit breaker selection

1. Determine the type and maintenance situation of Schneider circuit breaker according to the maintenance requirements of the line, and determine the selection of frame type, device type or current limiting type. Generally speaking, the Schneider frame circuit breaker can break the short-circuit current with a large device type and a large volume. Usually, the branch line chooses ...

Classification of Schneider molded case circuit breakers Classification of Schneider molded case circuit breakers

1. According to the device method, it is divided into: vertical installation and horizontal installation. 2. According to the use of circuit breakers: power distribution maintenance type, motor maintenance type. 3. According to the wiring method: board front wiring, board back wiring, plug-in wiring. ...

Precautions for the use and maintenance of instruments and meters - Schneider Precautions for the use and maintenance of instruments and meters - Schneider

Attention should be paid to the following matters during the use and maintenance of the appearance of the instrument: 1. Don't blindly knock and bump when overhauling, so as not to expand the problem, and the more you repair, the worse it will become. ​ 2. Do not plug and unplug various control boards and plugs with electricity. Due to the power-on ...

Schneider inverter motor control mode Schneider inverter motor control mode

Fundamentals of magnetic flux vector manipulation The control of a three-phase asynchronous motor is much more complicated than that of a DC motor because the current, voltage, induced potential, magnetic flux, etc., of the stator and rotor are all alternating. However, the stator winding of the three-phase asynchronous motor is a symmetrical three-phase winding, which exerts a ...

The meaning of the inching of Schneider inverter The meaning of the inching of Schneider inverter

The inch movement in Schneider inverter means that the control signal can drive the motor intermittently according to the certain rules, and the motor acts in strict accordance with the dynamic and stop instructions of the control signal, and the motor does not roll by inertia during the shutdown. It's like moving an inch and then stopping. The full name of Schneider inverter is "...

Schneider ATS48 soft starter issue Schneider ATS48 soft starter issue

1. What type of ATS48 power supply is? The control power supply of ATS48 selects communication input, and supplies power to the controller, input and output ports through internal power processing; The control power supply of Q series products is 220V-415V; Handling of the Y-Series ...

Schneider inverter maintenance power settings, waveform test problems Schneider inverter maintenance power settings, waveform test problems

1. After the inverter is repaired, the power number needs to be modified, don't forget it Generally, an inverter corresponds to a power number (also known as the number of horsepower), for example, a 75 kilowatt inverter is set under heavy load, and 100 kilowatts is set under light load. In this way, the customer will not use it to present ...

The difference between Schneider PLC and Siemens PLC The difference between Schneider PLC and Siemens PLC

There are three main differences, namely: different applications, different products, and different characteristics. 1. The application situation is different: the programmable manipulator produced by Siemens in Germany is also widely used in China.

Schneider Electric miniature circuit breaker accident prevention Schneider Electric miniature circuit breaker accident prevention

With the development of the electric power industry, now the electricity has been accompanied by every detail of our days, so the maintenance of the electric power industry, began to get more and more attention from everyone, because the circuit in the daily operation side, very simple because of overvoltage or undervoltage and present a certain problem, which ...

Steps for wiring and installation of rotary encoders – Schneider Steps for wiring and installation of rotary encoders – Schneider

Rotary encoder to roll the output pulse, through the counting equipment to know its position (PLC) we usually use incremental encoders, the incremental encoder output pulse signal can be directly input to the PLC, the high-speed counter of the PLC to count its pulse signal, in order to obtain the ...

U-tube manometer error analysis – Schneider U-tube manometer error analysis – Schneider

(1) Temperature error. This refers to the change of the length of the scale and the density of the working fluid due to the change of ambient temperature, and the former can be ignored in general, and the latter should be appropriately corrected. For example, when water is changed from 10°C to 20°C, its density changes from 999. 8kg/m^3 reduced to 999.8kg/m^3 ...

Advantages and disadvantages of orifice flowmeters – Schneider Advantages and disadvantages of orifice flowmeters – Schneider

The orifice flowmeter is a high-range ratio differential pressure flow device composed of a standard orifice plate and a multi-parameter differential pressure transmitter (or differential pressure transmitter, temperature transmitter and pressure transmitter), which can measure the flow rate of gas, steam, liquid and natural gas. Widely used in petroleum, chemical, metallurgy, electric power ...

Schneider inverter fault repair Schneider inverter fault repair

Inverter communication failure · Fault code: SLF Fault title: Inverter communication problem. Cause of the failure: Communication abort on the inverter communication bus. The way to deal with the fault: check whether the communication connection is normal: check the communication timeout setting: check the ...

How to choose the right inverter for the motor? How to choose the right inverter for the motor?

The inverter is an electric transmission element that is used in frequency conversion skills and microelectronics skills to control and communicate with the motor by changing the frequency and fluctuation of the power supply of the motor. The birth of the inverter cabinet originated from the communication motor ...

Inverter control motor speed method - Schneider Inverter control motor speed method - Schneider

1. Why can the rotation speed of the motor be changed freely? Motor rotation speed unit: r/min number of rotations per minute, can also be expressed as rpm. Example: 2-pole motor 50Hz 3000 [r/min] 4-pole motor 50Hz 1500 [r/min] Conclusion:...

Dual-fan inverter selection - Schneider Dual-fan inverter selection - Schneider

1. Qualified after inspection When selecting a double fan inverter, it must be strictly checked for its quality. The first requirement is that it must have relevant certificates of qualified inspection, and some qualified materials must be taken out. This is the only way to ensure that this change ...

The operation essentials of Schneider disconnectors The operation essentials of Schneider disconnectors

Schneider Barrier Features: First of all, Schneider Barrier Switch can be used to block the power supply, it can disconnect the live equipment from the high-voltage maintenance equipment, and it can also see a significant disconnection point on it. The second is that Schneider Barrier Switches are able to work with circuit breakers to reach the point where the operation of the system is changed.

Schneider power supply configuration UPS backup battery method Schneider power supply configuration UPS backup battery method

In order to ensure that the APCUPS power supply can continue to provide high-quality power to the computer in the event of a power outage, it is particularly important to equip the battery backup battery. When the frequency load does not agree to be supplied with power, the backup time of the UPS battery in the communication room should be greater than the time from the suspension of the mains power to the recovery or until the generator set is normal.

Frequency converter and PLC connection problems - Schneider Frequency converter and PLC connection problems - Schneider

When the inverter is used to form an automatic control system for control, in many cases, the PLC and the inverter are used together, and how to correctly connect the PLC and the inverter together has become the key to the success of the system. 1.PLC switch ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top