Precautions for external wiring of the inverter

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

In the process of connecting the line of the inverter, it is necessary to pay attention to the following aspects:

1. The power supply must be connected to the main circuit power terminal L1/R, L2/S, L3/T, if the power supply is connected to other terminals by mistake, the inverter will be damaged.

2. The grounding terminal must be well grounded, on the one hand, it can avoid electric shock or fire incidents, and on the other hand, it can reduce noise.

3. It is necessary to use crimp terminals to connect terminals and wires to ensure high reliability of connection.

                                 Precautions for external wiring of the inverter

4. After the circuit connection is completed, the following points need to be checked:

(1) Whether all the connections are correct

(2) Whether there is any missing wiring

(3) Whether there is a short circuit or a short circuit to the ground between each terminal and the connecting line

5. After putting in the power supply, if you want to change the wiring, you should first cut off the power supply, and it is necessary to pay attention to the DC part of the main circuit, the filter capacitor must be discharged at the end of the discharge demand, wait for the charging indicator to go out, and then use the DC voltmeter to test, and admit that the voltage value is less than the DC25V safety voltage value before you can start the operation.

More on that
Schneider drives copy replication parameters Schneider drives copy replication parameters

1. Copy and copy through the Chinese panel. Older inverters, if they support Chinese panels, such as ATV71, ATV61, etc., support VW3A1101 panels, they can use the proprietary 'open/save as' parameter on the panel to copy and copy, and the newer ATV610, ATV630, ATV930, ...

Schneider ATV71 selection and letter meaning Schneider ATV71 selection and letter meaning

The type of Schneider inverter generally reflects the rated voltage, rated power, and load requirements of the inverter (heavy or light load). Here are two examples: Example 1: Schneider Inverter Type: ATV71HD11N ...

Schneider inverter frequency signal source mode Schneider inverter frequency signal source mode

In order for the inverter to operate normally, it must have two basic conditions, that is, the frequency signal and the operating signal, let's talk about the first condition, which is the frequency signal of the inverter. Our intention to use the inverter is to change the ...

Suppression of higher harmonics of inverter - Schneider Suppression of higher harmonics of inverter - Schneider

1. About the management of higher harmonics on the output side of the inverter The magnetic noise skills brought about by the communication harmonic components contained in the output waveform controlled by PWM control have been increasingly used in various inverters, such as the selection of higher frequency switching components, the installation of filter devices at the output end of the inverter, etc.

Frequency converter main circuit fault solution - Schneider Frequency converter main circuit fault solution - Schneider

According to the statistical analysis of the frequency and shutdown time of the specific common problems of the inverter, the repair rate of the main power supply circuit accounts for more than 60%; The main operating parameters are set improperly, resulting in about 20% of common problems; 15% of the common problems of manipulating circuit boards; 5% of common problems are caused by incorrect operation and external anomalies ...

Schneider miniature circuit breaker problem analysis and answer Schneider miniature circuit breaker problem analysis and answer

Fault 1: The shell of Schneider MCB product is yellowed or burned. Reason 1: It is very likely that the magnetic coil inside the circuit breaker is burned out because of harmonics or high-frequency signals. Method 1: * The good thing is that the filtering can be satisfied with the use of 50Hz/60Hz power frequency. ...

Schneider ATS48 soft starter issue Schneider ATS48 soft starter issue

1. What type of ATS48 power supply is? The control power supply of ATS48 selects communication input, and supplies power to the controller, input and output ports through internal power processing; The control power supply of Q series products is 220V-415V; Handling of the Y-Series ...

Schneider disconnector operation inspection contents Schneider disconnector operation inspection contents

(1) Whether the closing condition of the isolation switch is not defective, and whether there is any failure or dislocation; (2) The porcelain insulation of the isolation switch should be free of defects, no cracks, no discharge phenomena and flashover traces; (3) Contact inspection: a. Check the contact ...

Schneider Modicon M100 Programmable Controller Features and Benefits Schneider Modicon M100 Programmable Controller Features and Benefits

The Schneider Electric Modicon M100 programmable controller is part of the Easy Series and is suitable for simple I/O logic control machines. characteristic AC power supply High-speed processor with 0.2μs/boolean amount Built-in a ...

Instrumentation overhaul points - Schneider Instrumentation overhaul points - Schneider

The test input does not conform to the "short" rule, and the problem is here. 1. Overhaul according to the comparator rules, fit it, the piece is good, and check the periphery; It doesn't fit, the piece is bad. 2. It does not fit the "virtual break" - there are ...

Schneider inverter motor control mode Schneider inverter motor control mode

Fundamentals of magnetic flux vector manipulation The control of a three-phase asynchronous motor is much more messy than that of a DC motor because the current, voltage, induced potential, magnetic flux, etc., of the stator and rotor are all alternating. However, the stator winding of the three-phase asynchronous motor is a symmetrical three-phase winding, which exerts a ...

Schneider Thermal Relay Model Meaning Schneider Thermal Relay Model Meaning

The function of the thermal relay is mainly used to carry out overload maintenance on the asynchronous motor, and his operating principle is that after the overload current passes through the thermal element, the bimetal sheet is heated and twisted to advance the action organization to drive the contact action, so as to disconnect the motor control circuit to realize the motor power-off thermal relay ...

Schneider UPS power supply preventive maintenance precautions Schneider UPS power supply preventive maintenance precautions

1 Contingency plan Contingency plans are the top priority of preventive protection. Arrangements need to be better partnered with service providers to be part of the corporate programme. This means implementing processes and procedures for every type of thing, including contingency plans. ...

Analysis of the causes of Schneider touch screen touch deviation Analysis of the causes of Schneider touch screen touch deviation

(1) Fault--: Contact error Phenomenon 1: The direction of the finger does not coincide with the mouse arrow. Reason 1: After installing the driver, there is no vertical contact with the bullseye center when correcting the bearing. Solution 1: Re-align the bearing. Phenomenon 2: Some districts ...

Maintenance and overhaul of frequency converters and soft starters Maintenance and overhaul of frequency converters and soft starters

The protection and viewing of inverters and soft starters is a useful means to prevent occasional equipment problems. In order to be useful for protection and inspection, inspection orders should be created to record and save the inherent characteristics of the equipment and the stability of the constituent parts, so as to prevent problems and problems that occur.

Frequency converter control motor leakage solution - Schneider Frequency converter control motor leakage solution - Schneider

Because the current at the input and output ends of the inverter contains high-frequency components, the leakage current formed by the high-frequency components when the inverter is driven is greater than that when the grid power supply is supplied. Because there are many varieties of circuit breakers, in some cases, even the inverter wires and motors ...

The UPS boot panel does not show that the UPS is not working - Schneider The UPS boot panel does not show that the UPS is not working - Schneider

Problem: After the UPS is turned on, there is no display on the panel, and the UPS does not work Problem analysis: Judging from the problem phenomenon, the problem lies in the mains input, the battery and the mains detection part and the battery voltage detection loop: 1. Check ...

Features of Schneider explosion-proof inverter boxes Features of Schneider explosion-proof inverter boxes

1. Aluminum alloy shell or steel plate welding, plastic spraying on the surface; 2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies; ​ 3. It mainly regulates the general three-phase difference by changing its output frequency.

Fault check steps for frequency converters - Schneider frequency converters Fault check steps for frequency converters - Schneider frequency converters

1. Check whether the appearance of the inverter is in good condition, including whether the indicator light is running normally, whether the task control function of the operation panel is complete, and carefully observe the appearance of the inverter in the operating state, and do the corresponding recording work; When repairing the inverter, check whether the voltage value and current value exceed the allowable ...

The difference between Schneider UPS and EPS power supply The difference between Schneider UPS and EPS power supply

1. Different safety standards UPS is mainly used to protect users' equipment or business from economic loss, and its product technical certification mainly includes Thiel certification, CQC certification, etc. The development of EPS power supply stems from the sudden failure of the power grid, in order to ensure the power safety and fire linkage needs, it can be supplied immediately.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top